These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

292 related articles for article (PubMed ID: 28301075)

  • 1. Clinical performance of high-resolution late gadolinium enhancement imaging with compressed sensing.
    Basha TA; Akçakaya M; Liew C; Tsao CW; Delling FN; Addae G; Ngo L; Manning WJ; Nezafat R
    J Magn Reson Imaging; 2017 Dec; 46(6):1829-1838. PubMed ID: 28301075
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accelerated late gadolinium enhancement cardiac MR imaging with isotropic spatial resolution using compressed sensing: initial experience.
    Akçakaya M; Rayatzadeh H; Basha TA; Hong SN; Chan RH; Kissinger KV; Hauser TH; Josephson ME; Manning WJ; Nezafat R
    Radiology; 2012 Sep; 264(3):691-9. PubMed ID: 22820734
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility study of a single breath-hold, 3D mDIXON pulse sequence for late gadolinium enhancement imaging of ischemic scar.
    Foley JRJ; Fent GJ; Garg P; Broadbent DA; Dobson LE; Chew PG; Brown LAE; Swoboda PP; Plein S; Higgins DM; Greenwood JP
    J Magn Reson Imaging; 2019 May; 49(5):1437-1445. PubMed ID: 30597661
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical evaluation of three-dimensional late enhancement MRI.
    Bratis K; Henningsson M; Grigoratos C; Omodarme MD; Chasapides K; Botnar R; Nagel E
    J Magn Reson Imaging; 2017 Jun; 45(6):1675-1683. PubMed ID: 27801994
    [TBL] [Abstract][Full Text] [Related]  

  • 5. REPAIRit: Improving Myocardial Nulling and Ghosting Artifacts of 3D Navigator-Gated Late Gadolinium Enhancement Imaging During Arrhythmia.
    Hu C; Huber S; Latif SR; Santacana-Laffitte G; Mojibian HR; Baldassarre LA; Peters DC
    J Magn Reson Imaging; 2019 Mar; 49(3):688-699. PubMed ID: 30252987
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Compressed sensing for rapid late gadolinium enhanced imaging of the left atrium: A preliminary study.
    Kamesh Iyer S; Tasdizen T; Burgon N; Kholmovski E; Marrouche N; Adluru G; DiBella E
    Magn Reson Imaging; 2016 Sep; 34(7):846-54. PubMed ID: 26968143
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 3D image fusion of whole-heart dynamic cardiac MR perfusion and late gadolinium enhancement: Intuitive delineation of myocardial hypoperfusion and scar.
    von Spiczak J; Mannil M; Kozerke S; Alkadhi H; Manka R
    J Magn Reson Imaging; 2018 Oct; 48(4):1129-1138. PubMed ID: 29603482
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of 3D phase-sensitive inversion-recovery and 2D inversion-recovery MRI at 3.0 T for the assessment of late gadolinium enhancement in patients with hypertrophic cardiomyopathy.
    Morita K; Utsunomiya D; Oda S; Komi M; Namimoto T; Hirai T; Hashida M; Takashio S; Yamamuro M; Yamashita Y
    Acad Radiol; 2013 Jun; 20(6):752-7. PubMed ID: 23473721
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Convolutional neural network-based approach for segmentation of left ventricle myocardial scar from 3D late gadolinium enhancement MR images.
    Zabihollahy F; White JA; Ukwatta E
    Med Phys; 2019 Apr; 46(4):1740-1751. PubMed ID: 30734937
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Motion-corrected 3D whole-heart water-fat high-resolution late gadolinium enhancement cardiovascular magnetic resonance imaging.
    Munoz C; Bustin A; Neji R; Kunze KP; Forman C; Schmidt M; Hajhosseiny R; Masci PG; Zeilinger M; Wuest W; Botnar RM; Prieto C
    J Cardiovasc Magn Reson; 2020 Jul; 22(1):53. PubMed ID: 32684167
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE.
    Pennig L; Lennartz S; Wagner A; Sokolowski M; Gajzler M; Ney S; Laukamp KR; Persigehl T; Bunck AC; Maintz D; Weiss K; Naehle CP; Doerner J
    J Cardiovasc Magn Reson; 2020 Dec; 22(1):89. PubMed ID: 33327958
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High spatial resolution free-breathing 3D late gadolinium enhancement cardiac magnetic resonance imaging in ischaemic and non-ischaemic cardiomyopathy: quantitative assessment of scar mass and image quality.
    Bizino MB; Tao Q; Amersfoort J; Siebelink HJ; van den Bogaard PJ; van der Geest RJ; Lamb HJ
    Eur Radiol; 2018 Sep; 28(9):4027-4035. PubMed ID: 29626239
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A dual flip angle 3D bSSFP magnetization transfer-like method to differentiate between recent and old myocardial infarction.
    Germain P; El Ghannudi S; Labani A; Jeung MY; Gangi A; Ohlmann P; Roy C
    J Magn Reson Imaging; 2018 Mar; 47(3):798-808. PubMed ID: 28727209
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid single-breath-hold 3D late gadolinium enhancement cardiac MRI using a stack-of-spirals acquisition.
    Shin T; Lustig M; Nishimura DG; Hu BS
    J Magn Reson Imaging; 2014 Dec; 40(6):1496-502. PubMed ID: 24243575
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach.
    Rutz T; Piccini D; Coppo S; Chaptinel J; Ginami G; Vincenti G; Stuber M; Schwitter J
    Int J Cardiovasc Imaging; 2016 Dec; 32(12):1735-1744. PubMed ID: 27549804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improved dark blood late gadolinium enhancement (DB-LGE) imaging using an optimized joint inversion preparation and T
    Basha TA; Tang MC; Tsao C; Tschabrunn CM; Anter E; Manning WJ; Nezafat R
    Magn Reson Med; 2018 Jan; 79(1):351-360. PubMed ID: 28382726
    [TBL] [Abstract][Full Text] [Related]  

  • 17. T(Rho) and magnetization transfer and INvErsion recovery (TRAMINER)-prepared imaging: A novel contrast-enhanced flow-independent dark-blood technique for the evaluation of myocardial late gadolinium enhancement in patients with myocardial infarction.
    Muscogiuri G; Rehwald WG; Schoepf UJ; Suranyi P; Litwin SE; De Cecco CN; Wichmann JL; Mangold S; Caruso D; Fuller SR; Bayer Nd RR; Varga-Szemes A
    J Magn Reson Imaging; 2017 May; 45(5):1429-1437. PubMed ID: 27690324
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric late gadolinium-enhanced myocardial imaging with retrospective inversion time selection.
    Kecskemeti S; Johnson K; François CJ; Schiebler ML; Unal O
    J Magn Reson Imaging; 2013 Nov; 38(5):1276-82. PubMed ID: 23389851
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.
    Menon RG; Miller GW; Jeudy J; Rajagopalan S; Shin T
    Magn Reson Med; 2017 Apr; 77(4):1533-1543. PubMed ID: 27122450
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic accuracy of late iodine-enhancement dual-energy computed tomography for the detection of chronic myocardial infarction compared with late gadolinium-enhancement 3-T magnetic resonance imaging.
    Wichmann JL; Bauer RW; Doss M; Stock W; Lehnert T; Bodelle B; Frellesen C; Vogl TJ; Kerl JM
    Invest Radiol; 2013 Dec; 48(12):851-6. PubMed ID: 23907104
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.