These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

333 related articles for article (PubMed ID: 28302527)

  • 1. Multiple plastic stents versus covered metal stent for treatment of anastomotic biliary strictures after liver transplantation: a prospective, randomized, multicenter trial.
    Tal AO; Finkelmeier F; Filmann N; Kylänpää L; Udd M; Parzanese I; Cantù P; Dechêne A; Penndorf V; Schnitzbauer A; Friedrich-Rust M; Zeuzem S; Albert JG
    Gastrointest Endosc; 2017 Dec; 86(6):1038-1045. PubMed ID: 28302527
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial.
    Martins FP; De Paulo GA; Contini MLC; Ferrari AP
    Gastrointest Endosc; 2018 Jan; 87(1):131.e1-131.e13. PubMed ID: 28455159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial.
    Coté GA; Slivka A; Tarnasky P; Mullady DK; Elmunzer BJ; Elta G; Fogel E; Lehman G; McHenry L; Romagnuolo J; Menon S; Siddiqui UD; Watkins J; Lynch S; Denski C; Xu H; Sherman S
    JAMA; 2016 Mar 22-29; 315(12):1250-7. PubMed ID: 27002446
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical efficacy of anti-migration features in fully covered metallic stents for anastomotic biliary strictures after liver transplantation: comparison of conventional and anti-migration stents.
    Bordaçahar B; Perdigao F; Leblanc S; Barret M; Duchmann JC; Guillaumot MA; Chaussade S; Scatton O; Prat F
    Gastrointest Endosc; 2018 Oct; 88(4):655-664. PubMed ID: 30003877
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficacy of self-expandable metal stents in management of benign biliary strictures and comparison with multiple plastic stents: a meta-analysis.
    Khan MA; Baron TH; Kamal F; Ali B; Nollan R; Ismail MK; Tombazzi C; Artifon ELA; Repici A; Khashab MA
    Endoscopy; 2017 Jul; 49(7):682-694. PubMed ID: 28561199
    [No Abstract]   [Full Text] [Related]  

  • 6. Managing the post-liver transplantation anastomotic biliary stricture: multiple plastic versus metal stents: a systematic review.
    Kao D; Zepeda-Gomez S; Tandon P; Bain VG
    Gastrointest Endosc; 2013 May; 77(5):679-91. PubMed ID: 23473000
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy and Optimal Duration of Metallic Stent in the Management of Refractory Anastomotic Stricture After Liver Transplantation.
    Jang S; Parsi MA; Lopez R; Bhatt A; Vargo JJ
    Clin Gastroenterol Hepatol; 2017 Nov; 15(11):1776-1781. PubMed ID: 28624651
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Randomized multicenter study of multiple plastic stents vs. covered self-expandable metallic stent in the treatment of biliary stricture in chronic pancreatitis.
    Haapamäki C; Kylänpää L; Udd M; Lindström O; Grönroos J; Saarela A; Mustonen H; Halttunen J
    Endoscopy; 2015 Jul; 47(7):605-10. PubMed ID: 25590182
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Self-Expandable Metallic Stent Is More Cost Efficient Than Plastic Stent in Treating Anastomotic Biliary Stricture.
    Jang S; Stevens T; Lopez R; Chahal P; Bhatt A; Sanaka M; Vargo JJ
    Dig Dis Sci; 2020 Feb; 65(2):600-608. PubMed ID: 31104197
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraductal fully covered self-expandable metal stent versus multiple plastic stents for treating biliary anastomotic strictures after liver transplantation.
    Sissingh NJ; de Vries BA; Inderson A; van Hoek B; van der Heide F; van Hooft JE
    Gastrointest Endosc; 2023 Apr; 97(4):704-712.e2. PubMed ID: 36460088
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Migration rate using fully covered metal stent in anastomotic strictures after liver transplantation: Results from the BASALT study group.
    Conigliaro R; Pigò F; Bertani H; ; Greco S; Burti C; Indriolo A; Di Sario A; Ortolani A; Maroni L; Tringali A; Barbaro F; Costamagna G; Magarotto A; Masci E; Mutignani M; Forti E; Tringali A; Parodi MC; Assandri L; Marrone C; Fantin A; Penagini R; Cantù P; ; Di Benedetto F; Ravelli P; Vivarelli M; Agnes S; Mazzaferro V; De Carlis L; Andorno E; Cillo U; Rossi G
    Liver Int; 2022 Aug; 42(8):1861-1871. PubMed ID: 35302273
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Covered self-expanding metal stents may be preferable to plastic stents in the treatment of chronic pancreatitis-related biliary strictures: a systematic review comparing 2 methods of stent therapy in benign biliary strictures.
    Siiki A; Helminen M; Sand J; Laukkarinen J
    J Clin Gastroenterol; 2014 Aug; 48(7):635-43. PubMed ID: 24275713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Endoscopic treatment of anastomotic biliary stricture after adult deceased donor liver transplantation with multiple plastic stents versus self-expandable metal stents: a systematic review and meta-analysis.
    Landi F; de'Angelis N; Sepulveda A; Martínez-Pérez A; Sobhani I; Laurent A; Soubrane O
    Transpl Int; 2018 Feb; 31(2):131-151. PubMed ID: 29090502
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Post-ERCP pancreatitis occurs more frequently in self-expandable metallic stents than multiple plastic stents on benign biliary strictures: a meta-analysis.
    Yang H; Yang Z; Hong J
    Ann Med; 2022 Dec; 54(1):2439-2449. PubMed ID: 36799364
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term outcomes of fully covered self-expandable metal stents for refractory biliary strictures after living donor liver transplantation: a retrospective study at a tertiary center.
    Cho SH; Lee HS; Huh G; Oh D; Song TJ; Seo DW; Lee SK
    Surg Endosc; 2024 Jun; 38(6):3223-3230. PubMed ID: 38649493
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Association of covered metallic stents with cholecystitis and stent migration in malignant biliary stricture.
    Jang S; Stevens T; Parsi M; Lopez R; Zuccaro G; Dumot J; Vargo JJ
    Gastrointest Endosc; 2018 Apr; 87(4):1061-1070. PubMed ID: 28867074
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metal versus plastic stents in the management of benign biliary strictures: systematic review and meta-analysis of randomized controlled trials.
    Kamal F; Ali Khan M; Lee-Smith W; Sharma S; Acharya A; Imam Z; Jowhar D; Esswein J; Kothadia J; Aziz M; Chandan S; Arain M; Howden CW; Ismail MK
    Eur J Gastroenterol Hepatol; 2022 May; 34(5):478-487. PubMed ID: 35170533
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Success and complications of an intra-ductal fully covered self-expanding metal stent (ID-FCSEMS) to treat anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT).
    Aepli P; St John A; Gupta S; Hourigan LF; Vaughan R; Efthymiou M; Kaffes A
    Surg Endosc; 2017 Apr; 31(4):1558-1563. PubMed ID: 27572066
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Management of liver transplantation biliary stricture: Results from a tertiary hospital.
    Martins FP; Kahaleh M; Ferrari AP
    World J Gastrointest Endosc; 2015 Jun; 7(7):747-57. PubMed ID: 26140103
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Endo-therapies for biliary duct-to-duct anastomotic stricture after liver transplantation: Outcomes of a nationwide survey.
    Cantù P; Tarantino I; Baldan A; Mutignani M; Tringali A; Lombardi G; Cerofolini A; Di Sario A; Catalano G; Bertani H; Ghinolfi D; Boarino V; Masci E; Bulajic M; Pisani A; Fantin A; Ligresti D; Barresi L; Traina M; Ravelli P; Forti E; Barbaro F; Costamagna G; Rodella L; Maroni L; Salizzoni M; Conigliaro R; Filipponi F; Merighi A; Staiano T; Monteleone M; Mazzaferro V; Zucchi E; Zilli M; Nadal E; Rosa R; Santi G; Parzanese I; De Carlis L; Donato MF; Lampertico P; Maggi U; Caccamo L; Rossi G; Vecchi M; Penagini R
    Liver Int; 2019 Jul; 39(7):1355-1362. PubMed ID: 30500104
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.