These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 28306522)

  • 1. Infrared analyzers for breast milk analysis: fat levels can influence the accuracy of protein measurements.
    Kwan C; Fusch G; Bahonjic A; Rochow N; Fusch C
    Clin Chem Lab Med; 2017 Oct; 55(12):1931-1935. PubMed ID: 28306522
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Milk analysis using milk analyzers in a standardized setting (MAMAS) study: A multicentre quality initiative.
    Kwan C; Fusch G; Rochow N; Fusch C;
    Clin Nutr; 2020 Jul; 39(7):2121-2128. PubMed ID: 31526612
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid measurement of macronutrients in breast milk: How reliable are infrared milk analyzers?
    Fusch G; Rochow N; Choi A; Fusch S; Poeschl S; Ubah AO; Lee SY; Raja P; Fusch C
    Clin Nutr; 2015 Jun; 34(3):465-76. PubMed ID: 24912866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of Correction Algorithms for Near-IR Analysis of Human Milk in an Independent Sample Set-Effect of Pasteurization.
    Kotrri G; Fusch G; Kwan C; Choi D; Choi A; Al Kafi N; Rochow N; Fusch C
    Nutrients; 2016 Feb; 8(3):119. PubMed ID: 26927169
    [TBL] [Abstract][Full Text] [Related]  

  • 5. "Bed Side" Human Milk Analysis in the Neonatal Intensive Care Unit: A Systematic Review.
    Fusch G; Kwan C; Kotrri G; Fusch C
    Clin Perinatol; 2017 Mar; 44(1):209-267. PubMed ID: 28159207
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration Adjustment of the Mid-infrared Analyzer for an Accurate Determination of the Macronutrient Composition of Human Milk.
    Billard H; Simon L; Desnots E; Sochard A; Boscher C; Riaublanc A; Alexandre-Gouabau MC; Boquien CY
    J Hum Lact; 2016 Aug; 32(3):NP19-27. PubMed ID: 26037506
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a mid-infrared analyzer for the determination of the macronutrient composition of human milk.
    Casadio YS; Williams TM; Lai CT; Olsson SE; Hepworth AR; Hartmann PE
    J Hum Lact; 2010 Nov; 26(4):376-83. PubMed ID: 20871090
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparing human milk macronutrients measured using analyzers based on mid-infrared spectroscopy and ultrasound and the application of machine learning in data fitting.
    Ruan H; Tang Q; Zhang Y; Zhao X; Xiang Y; Feng Y; Cai W
    BMC Pregnancy Childbirth; 2022 Jul; 22(1):562. PubMed ID: 35836199
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of the influence of pasteurization, freezing/thawing, and offer processes on human milk's macronutrient concentrations.
    Vieira AA; Soares FV; Pimenta HP; Abranches AD; Moreira ME
    Early Hum Dev; 2011 Aug; 87(8):577-80. PubMed ID: 21592688
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Target fortification of breast milk with fat, protein, and carbohydrates for preterm infants.
    Rochow N; Fusch G; Choi A; Chessell L; Elliott L; McDonald K; Kuiper E; Purcha M; Turner S; Chan E; Xia MY; Fusch C
    J Pediatr; 2013 Oct; 163(4):1001-7. PubMed ID: 23769498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Near-infrared reflectance analysis to evaluate the nitrogen and fat content of human milk in neonatal intensive care units.
    Corvaglia L; Battistini B; Paoletti V; Aceti A; Capretti MG; Faldella G
    Arch Dis Child Fetal Neonatal Ed; 2008 Sep; 93(5):F372-5. PubMed ID: 18192331
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Human Milk Analysis Using Mid-Infrared Spectroscopy.
    Groh-Wargo S; Valentic J; Khaira S; Super DM; Collin M
    Nutr Clin Pract; 2016 Apr; 31(2):266-72. PubMed ID: 26245540
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Infrared analyzers for the measurement of breastmilk macronutrient content in the clinical setting.
    Borràs-Novell C; Herranz Barbero A; Aldecoa-Bilbao V; Feixas Orellana G; Balcells Esponera C; Sánchez Ortiz E; García-Algar O; Iglesias Platas I
    Expert Rev Mol Diagn; 2020 Sep; 20(9):867-887. PubMed ID: 32876510
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Effect of Processing Donor Milk on Its Nutrient and Energy Content.
    Chang FY; Fang LJ; Chang CS; Wu TZ
    Breastfeed Med; 2020 Sep; 15(9):576-582. PubMed ID: 32598161
    [No Abstract]   [Full Text] [Related]  

  • 15. Rapid measurement of human milk macronutrients in the neonatal intensive care unit: accuracy and precision of fourier transform mid-infrared spectroscopy.
    Smilowitz JT; Gho DS; Mirmiran M; German JB; Underwood MA
    J Hum Lact; 2014 May; 30(2):180-9. PubMed ID: 24423984
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The macronutrients in human milk change after storage in various containers.
    Chang YC; Chen CH; Lin MC
    Pediatr Neonatol; 2012 Jun; 53(3):205-9. PubMed ID: 22770111
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of human milk composition using mid-infrared analyzers requires calibration adjustment.
    Buffin R; Decullier E; De Halleux V; Loys CM; Hays S; Studzinsky F; Jourdes E; Rigo J; Picaud JC
    J Perinatol; 2017 May; 37(5):552-557. PubMed ID: 28125098
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reference-free spectroscopic determination of fat and protein in milk in the visible and near infrared region below 1000nm using spatially resolved diffuse reflectance fiber probe.
    Bogomolov A; Belikova V; Galyanin V; Melenteva A; Meyer H
    Talanta; 2017 May; 167():563-572. PubMed ID: 28340762
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of macronutrient content in human milk measured by mid-infrared human milk analyzer and reference methods.
    Giuffrida F; Austin S; Cuany D; Sanchez-Bridge B; Longet K; Bertschy E; Sauser J; Thakkar SK; Lee LY; Affolter M
    J Perinatol; 2019 Mar; 39(3):497-503. PubMed ID: 30552375
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Human milk macronutrient analysis using point-of-care near-infrared spectrophotometry.
    Sauer CW; Kim JH
    J Perinatol; 2011 May; 31(5):339-43. PubMed ID: 21052045
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.