These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
191 related articles for article (PubMed ID: 28319252)
41. Simultaneous measurements of umbilical venous, fetal hepatic, and ductus venosus blood flow in growth-restricted human fetuses. Bellotti M; Pennati G; De Gasperi C; Bozzo M; Battaglia FC; Ferrazzi E Am J Obstet Gynecol; 2004 May; 190(5):1347-58. PubMed ID: 15167841 [TBL] [Abstract][Full Text] [Related]
42. Routine intraoperative Doppler sonography in the evaluation of complications after living-related donor liver transplantation. Choi JY; Lee JY; Lee JM; Kim SH; Lee MW; Han JK; Choi BI J Clin Ultrasound; 2007; 35(9):483-90. PubMed ID: 17583559 [TBL] [Abstract][Full Text] [Related]
43. [Does Doppler analysis of hepatic venous flow predict increased right atrial pressure and right ventricular dysfunction?]. Vinsonneau C; Carrat F; Boccara F; Buyukoglu B; Lamisse N; Cohen A Arch Mal Coeur Vaiss; 2001 Sep; 94(9):975-83. PubMed ID: 11603072 [TBL] [Abstract][Full Text] [Related]
44. Role of hepatic vein catheterisation and transient elastography in the diagnosis of idiopathic portal hypertension. Seijo S; Reverter E; Miquel R; Berzigotti A; Abraldes JG; Bosch J; García-Pagán JC Dig Liver Dis; 2012 Oct; 44(10):855-60. PubMed ID: 22721839 [TBL] [Abstract][Full Text] [Related]
45. Assessment of perineal body properties in women with stress urinary incontinence using Transperineal shear wave elastography. Li X; Zhang L; Li Y; Jiang Y; Zhao C; Fang S; Yang Z; Sun L Sci Rep; 2024 Sep; 14(1):21647. PubMed ID: 39289423 [TBL] [Abstract][Full Text] [Related]
47. Shear-wave elastography: a noninvasive tool for monitoring changing hepatic venous pressure gradients in patients with cirrhosis. Choi SY; Jeong WK; Kim Y; Kim J; Kim TY; Sohn JH Radiology; 2014 Dec; 273(3):917-26. PubMed ID: 25025464 [TBL] [Abstract][Full Text] [Related]
48. The role of hepatic arterial flow on portal venous and hepatic venous wedged pressure in the isolated perfused CCl4-cirrhotic liver. Zipprich A; Loureiro-Silva MR; D'Silva I; Groszmann RJ Am J Physiol Gastrointest Liver Physiol; 2008 Jul; 295(1):G197-G202. PubMed ID: 18497333 [TBL] [Abstract][Full Text] [Related]
49. Impact of food intake, ultrasound transducer, breathing maneuvers and body position on acoustic radiation force impulse (ARFI) elastometry of the liver. Goertz RS; Egger C; Neurath MF; Strobel D Ultraschall Med; 2012 Aug; 33(4):380-5. PubMed ID: 22723037 [TBL] [Abstract][Full Text] [Related]
50. Assessment of the arterial stiffness in patients with acute ischemic stroke using longitudinal elasticity modulus measurements obtained with Shear Wave Elastography. Li Z; Du L; Wang F; Luo X Med Ultrason; 2016 Jun; 18(2):182-9. PubMed ID: 27239652 [TBL] [Abstract][Full Text] [Related]
51. Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography. Dodd GD; Zajko AB; Orons PD; Martin MS; Eichner LS; Santaguida LA AJR Am J Roentgenol; 1995 May; 164(5):1119-24. PubMed ID: 7717217 [TBL] [Abstract][Full Text] [Related]
52. [Evaluation of hepatic venous flow patterns using a pulsed Doppler technique]. Sakoda S; Mitsunami K; Kinoshita M J Cardiol; 1990; 20(1):193-208. PubMed ID: 2093753 [TBL] [Abstract][Full Text] [Related]
53. Evaluation of liver stiffness with magnetic resonance elastography in patients with constrictive pericarditis: Preliminary findings. Fenstad ER; Dzyubak B; Oh JK; Williamson EE; F Glockner J; Young PM; Anavekar NS; Leise MD; Ehman RL; Araoz PA; Venkatesh SK J Magn Reson Imaging; 2016 Jul; 44(1):81-8. PubMed ID: 26691749 [TBL] [Abstract][Full Text] [Related]
54. Multifrequency time-harmonic elastography for the measurement of liver viscoelasticity in large tissue windows. Tzschätzsch H; Ipek-Ugay S; Trong MN; Guo J; Eggers J; Gentz E; Fischer T; Schultz M; Braun J; Sack I Ultrasound Med Biol; 2015 Mar; 41(3):724-33. PubMed ID: 25638319 [TBL] [Abstract][Full Text] [Related]
55. Relationship between the liver tissue shear modulus and histopathologic findings analyzed by intraoperative shear wave elastography and digital microscopically assisted morphometry in patients with hepatocellular carcinoma. Honjo M; Moriyasu F; Sugimoto K; Oshiro H; Sakamaki K; Kasuya K; Nagai T; Tsuchida A; Imai Y J Ultrasound Med; 2014 Jan; 33(1):61-71. PubMed ID: 24371100 [TBL] [Abstract][Full Text] [Related]
56. Short- and long-term hemodynamic effects of transjugular intrahepatic portosystemic shunts: a Doppler/manometric correlative study. Lafortune M; Martinet JP; Denys A; Patriquin H; Dauzat M; Dufresne MP; Colombato L; Pomier-Layrargues G AJR Am J Roentgenol; 1995 Apr; 164(4):997-1002. PubMed ID: 7726065 [TBL] [Abstract][Full Text] [Related]
57. Serial measurement of Doppler hepatic hemodynamic parameters for the diagnosis of acute rejection after live donor liver transplantation. Sugimoto H; Kato K; Hirota M; Takeda S; Kamei H; Nakamura T; Kiuchi T; Nakao A Liver Transpl; 2009 Sep; 15(9):1119-25. PubMed ID: 19718629 [TBL] [Abstract][Full Text] [Related]
58. Increased hepatic stiffness as consequence of high hepatic afterload in the Fontan circulation: a vascular Doppler and elastography study. Kutty SS; Peng Q; Danford DA; Fletcher SE; Perry D; Talmon GA; Scott C; Kugler JD; Duncan KF; Quiros-Tejeira RE; Kutty S; Hepatology; 2014 Jan; 59(1):251-60. PubMed ID: 23913702 [TBL] [Abstract][Full Text] [Related]
59. Towards compression-sensitive magnetic resonance elastography of the liver: sensitivity of harmonic volumetric strain to portal hypertension. Hirsch S; Guo J; Reiter R; Schott E; Büning C; Somasundaram R; Braun J; Sack I; Kroencke TJ J Magn Reson Imaging; 2014 Feb; 39(2):298-306. PubMed ID: 23649541 [TBL] [Abstract][Full Text] [Related]
60. Improvement of Shear Wave Motion Detection Using Harmonic Imaging in Healthy Human Liver. Amador C; Song P; Meixner DD; Chen S; Urban MW Ultrasound Med Biol; 2016 May; 42(5):1031-41. PubMed ID: 26803391 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]