693 related articles for article (PubMed ID: 28327093)
1. Continuous Non-invasive finger cuff CareTaker® comparable to invasive intra-arterial pressure in patients undergoing major intra-abdominal surgery.
Gratz I; Deal E; Spitz F; Baruch M; Allen IE; Seaman JE; Pukenas E; Jean S
BMC Anesthesiol; 2017 Mar; 17(1):48. PubMed ID: 28327093
[TBL] [Abstract][Full Text] [Related]
2. Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement.
Harju J; Vehkaoja A; Kumpulainen P; Campadello S; Lindroos V; Yli-Hankala A; Oksala N
J Clin Monit Comput; 2018 Feb; 32(1):13-22. PubMed ID: 28105538
[TBL] [Abstract][Full Text] [Related]
3. Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children.
Garnier RP; van der Spoel AG; Sibarani-Ponsen R; Markhorst DG; Boer C
Br J Anaesth; 2012 Oct; 109(4):609-15. PubMed ID: 22907342
[TBL] [Abstract][Full Text] [Related]
4. Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.
Sun J; Chen H; Zheng J; Mao B; Zhu S; Feng J
J Clin Monit Comput; 2017 Dec; 31(6):1189-1195. PubMed ID: 28000041
[TBL] [Abstract][Full Text] [Related]
5. A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.
Hager H; Mandadi G; Pulley D; Eagon JC; Mascha E; Nutter B; Kurz A
Obes Surg; 2009 Jun; 19(6):717-24. PubMed ID: 18618207
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of oscillometric noninvasive blood pressure compared with intra-arterial blood pressure in infants and small children during neurosurgical procedures: An observational study.
Meidert AS; Tholl M; Hüttl TK; Bernasconi P; Peraud A; Briegel J
Eur J Anaesthesiol; 2019 Jun; 36(6):400-405. PubMed ID: 31045698
[TBL] [Abstract][Full Text] [Related]
7. Non-invasive continuous arterial pressure and pulse pressure variation measured with Nexfin(®) in patients following major upper abdominal surgery: a comparative study.
de Wilde RB; de Wit F; Geerts BF; van Vliet AL; Aarts LP; Vuyk J; Jansen JR
Anaesthesia; 2016 Jul; 71(7):788-97. PubMed ID: 27291598
[TBL] [Abstract][Full Text] [Related]
8. Clinical Evaluation of a High-fidelity Upper Arm Cuff to Measure Arterial Blood Pressure during Noncardiac Surgery.
Briegel J; Bähner T; Kreitmeier A; Conter P; Fraccaroli L; Meidert AS; Tholl M; Papadakis G; Deunert A; Bauer A; Hoeft A; Pfeiffer UJ
Anesthesiology; 2020 Nov; 133(5):997-1006. PubMed ID: 33048167
[TBL] [Abstract][Full Text] [Related]
9. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients.
Hohn A; Defosse JM; Becker S; Steffen C; Wappler F; Sakka SG
Br J Anaesth; 2013 Aug; 111(2):178-84. PubMed ID: 23485882
[TBL] [Abstract][Full Text] [Related]
10. Noninvasive continuous arterial pressure monitoring with Clearsight during awake carotid endarterectomy: A prospective observational study.
Noto A; Sanfilippo F; De Salvo G; Crimi C; Benedetto F; Watson X; Cecconi M; David A
Eur J Anaesthesiol; 2019 Feb; 36(2):144-152. PubMed ID: 30562226
[TBL] [Abstract][Full Text] [Related]
11. Comparison of continuous non-invasive finger arterial pressure monitoring with conventional intermittent automated arm arterial pressure measurement in patients under general anaesthesia.
Vos JJ; Poterman M; Mooyaart EA; Weening M; Struys MM; Scheeren TW; Kalmar AF
Br J Anaesth; 2014 Jul; 113(1):67-74. PubMed ID: 24740992
[TBL] [Abstract][Full Text] [Related]
12. A comparison of continuous non-invasive arterial pressure with invasive radial and femoral pressure in patients undergoing cardiac surgery.
Broch O; Bein B; Gruenewald M; Carstens A; Illies C; Schöneich F; Steinfath M; Renner J
Minerva Anestesiol; 2013 Mar; 79(3):248-56. PubMed ID: 23254164
[TBL] [Abstract][Full Text] [Related]
13. Validation of noninvasive continuous arterial pressure measurement by ClearSight System™ during induction of anesthesia for cardiovascular surgery.
Tanioku T; Yoshida A; Aratani Y; Fujii K; Kawamata T
BMC Anesthesiol; 2020 Jul; 20(1):176. PubMed ID: 32690040
[TBL] [Abstract][Full Text] [Related]
14. Noninvasive continuous arterial blood pressure monitoring with Nexfin®.
Martina JR; Westerhof BE; van Goudoever J; de Beaumont EM; Truijen J; Kim YS; Immink RV; Jöbsis DA; Hollmann MW; Lahpor JR; de Mol BA; van Lieshout JJ
Anesthesiology; 2012 May; 116(5):1092-103. PubMed ID: 22415387
[TBL] [Abstract][Full Text] [Related]
15. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement.
Ilies C; Bauer M; Berg P; Rosenberg J; Hedderich J; Bein B; Hinz J; Hanss R
Br J Anaesth; 2012 Feb; 108(2):202-10. PubMed ID: 22171358
[TBL] [Abstract][Full Text] [Related]
16. A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor.
Mireles SA; Jaffe RA; Drover DR; Brock-Utne JG
J Clin Monit Comput; 2009 Jun; 23(3):169-74. PubMed ID: 19396553
[TBL] [Abstract][Full Text] [Related]
17. The perfusion index measured by the pulse oximeter affects the agreement between ClearSight and the arterial catheter-based blood pressures: A prospective observational study.
Yokose M; Mihara T; Takaya M; Yamamoto T; Saigusa Y; Takaki S; Goto T
PLoS One; 2019; 14(7):e0219511. PubMed ID: 31291340
[TBL] [Abstract][Full Text] [Related]
18. Continuous Noninvasive Arterial Pressure Monitoring in Obese Patients During Bariatric Surgery: An Evaluation of the Vascular Unloading Technique (Clearsight system).
Rogge DE; Nicklas JY; Schön G; Grothe O; Haas SA; Reuter DA; Saugel B
Anesth Analg; 2019 Mar; 128(3):477-483. PubMed ID: 30649073
[TBL] [Abstract][Full Text] [Related]
19. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.
Langwieser N; Prechtl L; Meidert AS; Hapfelmeier A; Bradaric C; Ibrahim T; Laugwitz KL; Schmid RM; Wagner JY; Saugel B
Clin Res Cardiol; 2015 Jun; 104(6):518-24. PubMed ID: 25618259
[TBL] [Abstract][Full Text] [Related]
20. Automated Pulse Oximeter Waveform Analysis to Track Changes in Blood Pressure During Anesthesia Induction: A Proof-of-Concept Study.
Ghamri Y; Proença M; Hofmann G; Renevey P; Bonnier G; Braun F; Axis A; Lemay M; Schoettker P
Anesth Analg; 2020 May; 130(5):1222-1233. PubMed ID: 32287129
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]