These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 28341193)

  • 1. Is Grey Level a Suitable Alternative to Low-Contrast Penetration as a Serial Measure of Sensitivity in Computerised Ultrasound Quality Assurance?
    Dudley NJ; Gibson NM
    Ultrasound Med Biol; 2017 Feb; 43(2):541-545. PubMed ID: 28341193
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A proposed enhancement to the in air sensitivity test for ultrasound quality assurance.
    Dudley NJ
    Phys Med; 2018 Sep; 53():1-3. PubMed ID: 30241743
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implementation and validation of three automated methods for measuring ultrasound maximum depth of penetration: application to ultrasound quality control.
    Gorny KR; Tradup DJ; Hangiandreou NJ
    Med Phys; 2005 Aug; 32(8):2615-28. PubMed ID: 16193792
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Objective performance testing and quality assurance of medical ultrasound equipment.
    Thijssen JM; Weijers G; de Korte CL
    Ultrasound Med Biol; 2007 Mar; 33(3):460-71. PubMed ID: 17275983
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Method of Correcting for the Effect of Temperature on Low-Contrast Penetration Measurement in Urethane Phantoms.
    Peake E; Warrington S; Dudley NJ; Morgan PS; Gibson NM
    Ultrasound Med Biol; 2019 Jun; 45(6):1483-1488. PubMed ID: 30967319
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A computerised quality control testing system for B-mode ultrasound.
    Gibson NM; Dudley NJ; Griffith K
    Ultrasound Med Biol; 2001 Dec; 27(12):1697-711. PubMed ID: 11839415
    [TBL] [Abstract][Full Text] [Related]  

  • 7. AAPM Task Group 128: quality assurance tests for prostate brachytherapy ultrasound systems.
    Pfeiffer D; Sutlief S; Feng W; Pierce HM; Kofler J
    Med Phys; 2008 Dec; 35(12):5471-89. PubMed ID: 19175107
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Objective measurements of image quality.
    Browne JE; Watson AJ; Gibson NM; Dudley NJ; Elliott AT
    Ultrasound Med Biol; 2004 Feb; 30(2):229-37. PubMed ID: 14998675
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical evaluation of chirp-coded excitation in medical ultrasound.
    Pedersen MH; Misaridis TX; Jensen JA
    Ultrasound Med Biol; 2003 Jun; 29(6):895-905. PubMed ID: 12837505
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simple uniformity and penetration phantoms for the quality assurance of ultrasound scanners.
    Groth MJ
    Australas Phys Eng Sci Med; 1994 Dec; 17(4):200-5. PubMed ID: 7872901
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1.
    Goodsitt MM; Carson PL; Witt S; Hykes DL; Kofler JM
    Med Phys; 1998 Aug; 25(8):1385-406. PubMed ID: 9725125
    [No Abstract]   [Full Text] [Related]  

  • 12. A pre-clinical phantom comparison of tissue harmonic and brightness mode imaging for application in ultrasound guided prostate brachytherapy.
    Sandhu GK; Dunscombe PB; Khan RF
    Phys Med; 2011 Jul; 27(3):153-62. PubMed ID: 21035371
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The resolution integral: visual and computational approaches to characterizing ultrasound images.
    MacGillivray TJ; Ellis W; Pye SD
    Phys Med Biol; 2010 Sep; 55(17):5067-88. PubMed ID: 20702928
    [TBL] [Abstract][Full Text] [Related]  

  • 14. MO-D-218-02: Ultrasound Phantoms in Image Quality Measurements and Performance Assessment.
    Madsen E
    Med Phys; 2012 Jun; 39(6Part21):3870. PubMed ID: 28518253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Transcutaneous ultrasound].
    Hünerbein M; Chopra SS; Schlag PM
    Chirurg; 2007 May; 78(5):407-10, 412. PubMed ID: 17431555
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quality assurance phantom for digital dental imaging.
    Mah P; McDavid WD; Dove SB
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Nov; 112(5):632-9. PubMed ID: 21862364
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improvement of penetration of modified amplitude and phase estimation beamformer.
    Hasegawa H
    J Med Ultrason (2001); 2017 Jan; 44(1):3-11. PubMed ID: 27443916
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multielement synthetic transmit aperture imaging using temporal encoding.
    Gammelmark KL; Jensen JA
    IEEE Trans Med Imaging; 2003 Apr; 22(4):552-63. PubMed ID: 12774901
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy.
    Baek J; Huh J; Kim M; Hyun An S; Oh Y; Kim D; Chung K; Cho S; Lee R
    Med Phys; 2013 Feb; 40(2):021704. PubMed ID: 23387727
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early experience with automated B-mode quality assurance tests.
    Dudley NJ; Gibson NM
    Ultrasound; 2014 Feb; 22(1):15-20. PubMed ID: 27433188
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.