These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
438 related articles for article (PubMed ID: 28342291)
1. Advances in MRI around metal. Jungmann PM; Agten CA; Pfirrmann CW; Sutter R J Magn Reson Imaging; 2017 Oct; 46(4):972-991. PubMed ID: 28342291 [TBL] [Abstract][Full Text] [Related]
2. Managing hardware-related metal artifacts in MRI: current and evolving techniques. Feuerriegel GC; Sutter R Skeletal Radiol; 2024 Sep; 53(9):1737-1750. PubMed ID: 38381196 [TBL] [Abstract][Full Text] [Related]
3. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants. Fritz J; Ahlawat S; Demehri S; Thawait GK; Raithel E; Gilson WD; Nittka M Invest Radiol; 2016 Oct; 51(10):666-76. PubMed ID: 27518214 [TBL] [Abstract][Full Text] [Related]
4. SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging. Ai T; Padua A; Goerner F; Nittka M; Gugala Z; Jadhav S; Trelles M; Johnson RF; Lindsey RW; Li X; Runge VM Invest Radiol; 2012 May; 47(5):267-76. PubMed ID: 22266987 [TBL] [Abstract][Full Text] [Related]
5. MR Imaging with Metal-suppression Sequences for Evaluation of Total Joint Arthroplasty. Talbot BS; Weinberg EP Radiographics; 2016; 36(1):209-25. PubMed ID: 26587889 [TBL] [Abstract][Full Text] [Related]
6. Advances in Metal Artifact Reduction Techniques for Periprosthetic Soft Tissue Imaging. Ariyanayagam T; Malcolm PN; Toms AP Semin Musculoskelet Radiol; 2015 Sep; 19(4):328-34. PubMed ID: 26583361 [TBL] [Abstract][Full Text] [Related]
8. Off-resonance suppression for multispectral MR imaging near metallic implants. den Harder JC; van Yperen GH; Blume UA; Bos C Magn Reson Med; 2015 Jan; 73(1):233-43. PubMed ID: 24488684 [TBL] [Abstract][Full Text] [Related]
9. Improved Visualization of Juxtaprosthetic Tissue Using Metal Artifact Reduction Magnetic Resonance Imaging: Experimental and Clinical Optimization of Compressed Sensing SEMAC. Jungmann PM; Bensler S; Zingg P; Fritz B; Pfirrmann CW; Sutter R Invest Radiol; 2019 Jan; 54(1):23-31. PubMed ID: 30351283 [TBL] [Abstract][Full Text] [Related]
10. Metal artefact reduction in MRI at both 1.5 and 3.0 T using slice encoding for metal artefact correction and view angle tilting. Reichert M; Ai T; Morelli JN; Nittka M; Attenberger U; Runge VM Br J Radiol; 2015 Apr; 88(1048):20140601. PubMed ID: 25613398 [TBL] [Abstract][Full Text] [Related]
11. View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application. Jungmann PM; Ganter C; Schaeffeler CJ; Bauer JS; Baum T; Meier R; Nittka M; Pohlig F; Rechl H; von Eisenhart-Rothe R; Rummeny EJ; Woertler K PLoS One; 2015; 10(4):e0124922. PubMed ID: 25909472 [TBL] [Abstract][Full Text] [Related]
12. New-Generation Low-Field Magnetic Resonance Imaging of Hip Arthroplasty Implants Using Slice Encoding for Metal Artifact Correction: First In Vitro Experience at 0.55 T and Comparison With 1.5 T. Khodarahmi I; Brinkmann IM; Lin DJ; Bruno M; Johnson PM; Knoll F; Keerthivasan MB; Chandarana H; Fritz J Invest Radiol; 2022 Aug; 57(8):517-526. PubMed ID: 35239614 [TBL] [Abstract][Full Text] [Related]
13. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC. Fritz J; Fritz B; Thawait GK; Raithel E; Gilson WD; Nittka M; Mont MA Skeletal Radiol; 2016 Oct; 45(10):1345-56. PubMed ID: 27497594 [TBL] [Abstract][Full Text] [Related]
14. CT and MRI Techniques for Imaging Around Orthopedic Hardware. Do TD; Sutter R; Skornitzke S; Weber MA Rofo; 2018 Jan; 190(1):31-41. PubMed ID: 28934809 [TBL] [Abstract][Full Text] [Related]
15. Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T Lee YH; Hahn S; Kim E; Suh JS Magn Reson Med Sci; 2016 Oct; 15(4):371-378. PubMed ID: 26902679 [TBL] [Abstract][Full Text] [Related]
16. Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction. den Harder JC; van Yperen GH; Blume UA; Bos C Magn Reson Med; 2015 Jan; 73(1):318-24. PubMed ID: 24488701 [TBL] [Abstract][Full Text] [Related]
17. Metal Artifact Reduction Magnetic Resonance Imaging Around Arthroplasty Implants: The Negative Effect of Long Echo Trains on the Implant-Related Artifact. Kumar NM; de Cesar Netto C; Schon LC; Fritz J Invest Radiol; 2017 May; 52(5):310-316. PubMed ID: 28079703 [TBL] [Abstract][Full Text] [Related]
18. Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T. Lee YH; Lim D; Kim E; Kim S; Song HT; Suh JS Magn Reson Imaging; 2014 Oct; 32(8):1001-5. PubMed ID: 24925839 [TBL] [Abstract][Full Text] [Related]
19. Optimization of Scan Time in MRI for Total Hip Prostheses: SEMAC Tailoring for Prosthetic Implants Containing Different Types of Metals. Deligianni X; Bieri O; Elke R; Wischer T; Egelhof T Rofo; 2015 Dec; 187(12):1116-22. PubMed ID: 26327671 [TBL] [Abstract][Full Text] [Related]
20. Basic and Advanced Metal-Artifact Reduction Techniques at Ultra-High Field 7-T Magnetic Resonance Imaging-Phantom Study Investigating Feasibility and Efficacy. Germann C; Falkowski AL; von Deuster C; Nanz D; Sutter R Invest Radiol; 2022 Jun; 57(6):387-398. PubMed ID: 35025835 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]