These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 28343078)

  • 1. Development and validation of liquid chromatography tandem mass spectrometry method quantitative determination of polymyxin B1, polymyxin B2, polymyxin B3 and isoleucine-polymyxin B1 in human plasma and its application in clinical studies.
    Hee KH; Leaw YKJ; Ong JL; Lee LS
    J Pharm Biomed Anal; 2017 Jun; 140():91-97. PubMed ID: 28343078
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of polymixin B1, B2, ile-B1, E1, and E2 in human plasma and its clinical pharmacokinetic application.
    Xiang D; Li N; Yang G; Yu H; Li X; Qiu L; Chen Y; Liu L; Gong X
    J Pharm Biomed Anal; 2024 Nov; 250():116403. PubMed ID: 39116583
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Determination of Polymyxin B in Critically Ill Patients by the HPLC-MS/MS Method.
    Wang Y; Chen J; Du J; Lei L; Zhao B; Bai Y; Chen D; Wang X; Chen C
    Int J Anal Chem; 2023; 2023():6674009. PubMed ID: 37063108
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous quantitation of polymyxin B1, polymyxin B2 and polymyxin B1-1 in human plasma and treated human urine using solid phase extraction and liquid chromatography-tandem mass spectrometry.
    Meng M; Wang L; Liu S; Jaber OM; Gao L; Chevrette L; Reuschel S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Feb; 1012-1013():23-36. PubMed ID: 26803416
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The development and validation of a simple liquid chromatography-tandem mass spectrometry method for polymyxin B1 and B2 quantification in different matrices.
    Covelli J; Ruszaj D; Straubinger R; Li J; Rao GG
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Oct; 1065-1066():112-118. PubMed ID: 28961485
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Simple and Robust Liquid Chromatography With Tandem Mass Spectrometry Analytical Method for Therapeutic Drug Monitoring of Plasma and Cerebrospinal Fluid Polymyxin B1 and B2.
    Wang P; Zhang Q; Qin Z; Xing H; Xu M; Pei H; Yang J; Zhang X
    Ther Drug Monit; 2020 Oct; 42(5):716-723. PubMed ID: 32941397
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simple HPLC-MS/MS method for the determination of polymyxin B in human plasma and its application in the pharmacokinetic study in elderly patients infected with multidrug-resistant Gram-negative bacteria.
    Hu S; Guo N; Zeng J; Li Y; Zhang Y; Jiang J; Leng B; Shen C
    Front Pharmacol; 2024; 15():1396307. PubMed ID: 39221151
    [No Abstract]   [Full Text] [Related]  

  • 8. Determination of polymyxin B in human plasma and epithelial lining fluid using LC-MS/MS and its clinical application in therapeutic drug monitoring.
    Zhang B; Li X; Chen Y; Chen B; Cheng Y; Lin H; Que W; Liu M; Zhou L; Zhang H; Qiu H; Wu C
    J Pharm Biomed Anal; 2023 Apr; 227():115291. PubMed ID: 36822067
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A validated ultra-performance liquid chromatography-tandem mass spectrometry method for the quantification of polymyxin B in mouse serum and epithelial lining fluid: application to pharmacokinetic studies.
    He J; Gao S; Hu M; Chow DS; Tam VH
    J Antimicrob Chemother; 2013 May; 68(5):1104-10. PubMed ID: 23341128
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development and validation of liquid chromatography tandem mass spectrometry method for simultaneous quantification of first line tuberculosis drugs and metabolites in human plasma and its application in clinical study.
    Hee KH; Seo JJ; Lee LS
    J Pharm Biomed Anal; 2015 Jan; 102():253-60. PubMed ID: 25459921
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Therapeutic drug monitoring of polymyxin B by LC-MS/MS in plasma and urine.
    Liu X; Yu Z; Wang Y; Wu H; Bian X; Li X; Fan Y; Guo B; Zhang J
    Bioanalysis; 2020 Jun; 12(12):845-855. PubMed ID: 32558589
    [No Abstract]   [Full Text] [Related]  

  • 12. Determination of the sulfate and glucuronide conjugates of levornidazole in human plasma and urine, and levornidazole and its five metabolites in human feces by high performance liquid chromatography-tandem mass spectrometry.
    He G; Guo B; Zhang J; Li Y; Wu X; Fan Y; Chen Y; Cao G; Yu J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Apr; 1081-1082():87-100. PubMed ID: 29518721
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and validation of a bioanalytical method for the simultaneous determination of heroin, its main metabolites, naloxone and naltrexone by LC-MS/MS in human plasma samples: Application to a clinical trial of oral administration of a heroin/naloxone formulation.
    Moreno-Vicente R; Fernández-Nieva Z; Navarro A; Gascón-Crespí I; Farré-Albaladejo M; Igartua M; Hernández RM; Pedraz JL
    J Pharm Biomed Anal; 2015 Oct; 114():105-12. PubMed ID: 26037158
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry.
    Bihan K; Lu Q; Enjalbert M; Apparuit M; Langeron O; Rouby JJ; Funck-Brentano C; Zahr N
    Ther Drug Monit; 2016 Dec; 38(6):796-803. PubMed ID: 27684296
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High performance liquid chromatography-mass spectrometry assay for polymyxin B1 and B2 in human plasma.
    Thomas TA; Broun EC; Abildskov KM; Kubin CJ; Horan J; Yin MT; Cremers S
    Ther Drug Monit; 2012 Aug; 34(4):398-405. PubMed ID: 22735673
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development and validation of an LC-MS/MS method for the simultaneous quantification of seven constituents in rat plasma and application in a pharmacokinetic study of the Zaoren Anshen prescription.
    Zhao A; Zhang L; Li R; Shang J; Yi H; Wang Y; Zhang D; Wang S; Fang M
    Biomed Chromatogr; 2018 Feb; 32(2):. PubMed ID: 28744886
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous determination of six hydrophilic components in rat plasma after oral administration of Jitai tablet by liquid chromatography-electrospray ionization-tandem mass spectrometry: application to a pharmacokinetic study.
    Wang SP; Liu L; Wang LL; Jiang P; Xiang L; Zhang WD; Liu RH
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jan; 912():75-84. PubMed ID: 23261824
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma.
    Xue YJ; Akinsanya JB; Liu J; Unger SE
    Rapid Commun Mass Spectrom; 2006; 20(18):2660-8. PubMed ID: 16912986
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of six steroidal saponins in rat plasma and its application to a pharmacokinetics study.
    Liu Z; Qin W; Zhu Z; Liu Y; Sun F; Chai Y; Xia P
    Steroids; 2015 Apr; 96():21-9. PubMed ID: 25617741
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of fenretinide and its metabolites in human plasma by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics.
    Cho HE; Min HK
    J Pharm Biomed Anal; 2017 Jan; 132():117-124. PubMed ID: 27701038
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.