These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
240 related articles for article (PubMed ID: 28345391)
21. Repeat syphilis has a different immune response compared with initial syphilis: an analysis of biomarker kinetics in two cohorts. Kenyon C; Tsoumanis A; Osbak K; Van Esbroeck M; Florence E; Crucitti T; Kestens L Sex Transm Infect; 2018 May; 94(3):180-186. PubMed ID: 29021408 [TBL] [Abstract][Full Text] [Related]
22. Investigation of Concordance in Two Automated Rapid Plasma Reagin Assays and Conventional Manual Card Method. Kim YJ; Cho SY; Kim MJ; Yang JJ; Lee HJ; Park TS Clin Lab; 2015; 61(7):861-3. PubMed ID: 26299090 [No Abstract] [Full Text] [Related]
23. Rapid plasma reagin titer variation in the 2 weeks after syphilis therapy. Holman KM; Wolff M; Seña AC; Martin DH; Behets F; Van Damme K; Leone P; McNeil L; Gehrig ML; Hook EW Sex Transm Dis; 2012 Aug; 39(8):645-7. PubMed ID: 22801348 [TBL] [Abstract][Full Text] [Related]
24. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique. Montoya PJ; Lukehart SA; Brentlinger PE; Blanco AJ; Floriano F; Sairosse J; Gloyd S Bull World Health Organ; 2006 Feb; 84(2):97-104. PubMed ID: 16501726 [TBL] [Abstract][Full Text] [Related]
25. Cost-effectiveness of a dual non-treponemal/treponemal syphilis point-of-care test to prevent adverse pregnancy outcomes in sub-Saharan Africa. Owusu-Edusei K; Gift TL; Ballard RC Sex Transm Dis; 2011 Nov; 38(11):997-1003. PubMed ID: 21992974 [TBL] [Abstract][Full Text] [Related]
26. Rapid Syphilis Testing for Men Who Have Sex With Men in Outreach Settings: Evaluation of Test Performance and Impact on Time to Treatment. Obafemi OA; Wendel KA; Anderson TS; Scott TE; Rowan SE; Travanty EA; Rietmeijer CA Sex Transm Dis; 2019 Mar; 46(3):191-195. PubMed ID: 30363029 [TBL] [Abstract][Full Text] [Related]
27. High Number of Positive Rapid Plasma Reagin With Low Titers Using the Automated AIX 1000 RPR System. Palavecino EL; Soltani S; Keller R; Elliott S; McNeil CJ Sex Transm Dis; 2022 Jan; 49(1):e11-e12. PubMed ID: 34618786 [TBL] [Abstract][Full Text] [Related]
28. Performance of the rapid plasma reagin and the rapid syphilis screening tests in the diagnosis of syphilis in field conditions in rural Africa. West B; Walraven G; Morison L; Brouwers J; Bailey R Sex Transm Infect; 2002 Aug; 78(4):282-5. PubMed ID: 12181468 [TBL] [Abstract][Full Text] [Related]
29. Evaluation of diagnostic serological results in cases of suspected primary syphilis infection. Gratzer B; Pohl D; Hotton AL Sex Transm Dis; 2014 May; 41(5):285-9. PubMed ID: 24722379 [TBL] [Abstract][Full Text] [Related]
30. Evaluation of three serological tests manufactured in Belarus for the diagnosis of syphilis. Shimanskaya I; Zhurauskaya L; Pankratov O; Unemo M; Ballard RC; Domeika M Acta Derm Venereol; 2011 May; 91(3):299-302. PubMed ID: 21369683 [TBL] [Abstract][Full Text] [Related]
31. Characteristics of primary and late latent syphilis cases which were initially non-reactive with the rapid plasma reagin as the screening test. Singh AE; Wong T; De P Int J STD AIDS; 2008 Jul; 19(7):464-8. PubMed ID: 18574118 [TBL] [Abstract][Full Text] [Related]
32. Evaluation of a new rapid plasma reagin card test as a screening test for syphilis. Perryman MW; Larsen SA; Hambie EA; Pettit DE; Mullally RL; Whittington W J Clin Microbiol; 1982 Aug; 16(2):286-90. PubMed ID: 6749891 [TBL] [Abstract][Full Text] [Related]
33. Effect of adverse storage conditions of antigen reagent on performance of the rapid plasma reagin test. van Dyck E; de Deken B; Laga M Int J STD AIDS; 2001 May; 12(5):299-301. PubMed ID: 11368802 [TBL] [Abstract][Full Text] [Related]
34. Diagnostic dilemma of the single screening test used in the diagnosis of syphilis in Nepal. Dumre SP; Shakya G; Acharya D; Malla S; Adhikari N Nepal Med Coll J; 2011 Dec; 13(4):238-40. PubMed ID: 23016470 [TBL] [Abstract][Full Text] [Related]
35. [Comparison of quantitative results among two automated Rapid Plasma Reagin (RPR) assays and a manual RPR test]. Kim YS; Lee J; Lee HK; Kim H; Kwon HJ; Min KO; Seo EJ; Kim SY Korean J Lab Med; 2009 Aug; 29(4):331-7. PubMed ID: 19726896 [TBL] [Abstract][Full Text] [Related]
36. Field evaluation of simple rapid tests in the diagnosis of syphilis. Nessa K; Alam A; Chawdhury FA; Huq M; Nahar S; Salauddin G; Khursheed S; Rahman S; Gurley E; Breiman RF; Rahman M Int J STD AIDS; 2008 May; 19(5):316-20. PubMed ID: 18482961 [TBL] [Abstract][Full Text] [Related]
37. Evaluation of reagin card tests for syphilis. Stevens RW; Gombel K; Gaafar HA Health Lab Sci; 1978 Apr; 15(2):81-5. PubMed ID: 355209 [TBL] [Abstract][Full Text] [Related]
38. Evaluation of the serodia Treponema pallidum particle agglutination, the Murex Syphilis ICE and the Enzywell TP tests for serodiagnosis of syphilis. Aktas G; Young H; Moyes A; Badur S Int J STD AIDS; 2005 Apr; 16(4):294-8. PubMed ID: 15899082 [TBL] [Abstract][Full Text] [Related]
39. The impact of combined antiretroviral therapy on biologic false-positive rapid plasma reagin serologies in a longitudinal cohort of HIV-infected persons. Oboho IK; Gebo KA; Moore RD; Ghanem KG Clin Infect Dis; 2013 Oct; 57(8):1197-202. PubMed ID: 23828913 [TBL] [Abstract][Full Text] [Related]
40. On-site rapid antenatal syphilis screening with an immunochromatographic strip improves case detection and treatment in rural South African clinics. Bronzan RN; Mwesigwa-Kayongo DC; Narkunas D; Schmid GP; Neilsen GA; Ballard RC; Karuhije P; Ddamba J; Nombekela E; Hoyi G; Dlali P; Makwedini N; Fehler HG; Blandford JM; Ryan C Sex Transm Dis; 2007 Jul; 34(7 Suppl):S55-60. PubMed ID: 17139234 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]