464 related articles for article (PubMed ID: 28353447)
1. On the experimental validation of model-based dose calculation algorithms for
Pappas EP; Zoros E; Moutsatsos A; Peppa V; Zourari K; Karaiskos P; Papagiannis P
Phys Med Biol; 2017 May; 62(10):4160-4182. PubMed ID: 28353447
[TBL] [Abstract][Full Text] [Related]
2. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
[TBL] [Abstract][Full Text] [Related]
3. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms.
Moura ES; Micka JA; Hammer CG; Culberson WS; DeWerd LA; Rostelato ME; Zeituni CA
Med Phys; 2015 Apr; 42(4):1566-74. PubMed ID: 25832047
[TBL] [Abstract][Full Text] [Related]
4. Determination of absorbed dose to water around a clinical HDR (192)Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response.
Carlsson Tedgren A; Elia R; Hedtjarn H; Olsson S; Alm Carlsson G
Med Phys; 2012 Feb; 39(2):1133-40. PubMed ID: 22320824
[TBL] [Abstract][Full Text] [Related]
5. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate
Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060
[TBL] [Abstract][Full Text] [Related]
6. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE® radiochromic plastic.
Palmer AL; Di Pietro P; Alobaidli S; Issa F; Doran S; Bradley D; Nisbet A
Med Phys; 2013 Jun; 40(6):061707. PubMed ID: 23718586
[TBL] [Abstract][Full Text] [Related]
7. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
[TBL] [Abstract][Full Text] [Related]
8. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
[TBL] [Abstract][Full Text] [Related]
9. A MC-based anthropomorphic test case for commissioning model-based dose calculation in interstitial breast 192-Ir HDR brachytherapy.
Peppa V; Thomson RM; Enger SA; Fonseca GP; Lee C; Lucero JNE; Mourtada F; Siebert FA; Vijande J; Papagiannis P
Med Phys; 2023 Jul; 50(7):4675-4687. PubMed ID: 37194638
[TBL] [Abstract][Full Text] [Related]
10. On the use of a novel Ferrous Xylenol-orange gelatin dosimeter for HDR brachytherapy commissioning and quality assurance testing.
Pappas EP; Peppa V; Hourdakis CJ; Karaiskos P; Papagiannis P
Phys Med; 2018 Jan; 45():162-169. PubMed ID: 29472082
[TBL] [Abstract][Full Text] [Related]
11. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
[TBL] [Abstract][Full Text] [Related]
12. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method.
Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K
Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956
[TBL] [Abstract][Full Text] [Related]
13. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
McCaw TJ; Micka JA; DeWerd LA
Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
[TBL] [Abstract][Full Text] [Related]
14. A user-oriented procedure for the commissioning and quality assurance testing of treatment planning system dosimetry in high-dose-rate brachytherapy.
Peppa V; Pantelis E; Pappas E; Lahanas V; Loukas C; Papagiannis P
Brachytherapy; 2016; 15(2):252-62. PubMed ID: 26727331
[TBL] [Abstract][Full Text] [Related]
15. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions.
Candela-Juan C; Niatsetski Y; van der Laarse R; Granero D; Ballester F; Perez-Calatayud J; Vijande J
Med Phys; 2016 Apr; 43(4):1639. PubMed ID: 27036563
[TBL] [Abstract][Full Text] [Related]
16. A CT-based analytical dose calculation method for HDR 192Ir brachytherapy.
Poon E; Verhaegen F
Med Phys; 2009 Sep; 36(9):3982-94. PubMed ID: 19810471
[TBL] [Abstract][Full Text] [Related]
17. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation.
Beaulieu L; Carlsson Tedgren A; Carrier JF; Davis SD; Mourtada F; Rivard MJ; Thomson RM; Verhaegen F; Wareing TA; Williamson JF
Med Phys; 2012 Oct; 39(10):6208-36. PubMed ID: 23039658
[TBL] [Abstract][Full Text] [Related]
18. Experimental determination of the Task Group-43 dosimetric parameters of the new I25.S17plus (125)I brachytherapy source.
Moutsatsos A; Pantelis E; Papagiannis P; Baltas D
Brachytherapy; 2014; 13(6):618-26. PubMed ID: 25108795
[TBL] [Abstract][Full Text] [Related]
19. Effect of improved TLD dosimetry on the determination of dose rate constants for (125)I and (103)Pd brachytherapy seeds.
Rodriguez M; Rogers DW
Med Phys; 2014 Nov; 41(11):114301. PubMed ID: 25370677
[TBL] [Abstract][Full Text] [Related]
20. Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator.
Petrokokkinos L; Zourari K; Pantelis E; Moutsatsos A; Karaiskos P; Sakelliou L; Seimenis I; Georgiou E; Papagiannis P
Med Phys; 2011 Apr; 38(4):1981-92. PubMed ID: 21626931
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]