103 related articles for article (PubMed ID: 28361128)
1. Design of dual multiple aperture devices for dynamical fluence field modulated CT.
Mathews AJ; Tilley S; Gang G; Kawamoto S; Zbijewski W; Siewerdsen JH; Levinson R; Webster Stayman J
Conf Proc Int Conf Image Form Xray Comput Tomogr; 2016 Jul; 2016():29-32. PubMed ID: 28361128
[TBL] [Abstract][Full Text] [Related]
2. Dynamic fluence field modulation in computed tomography using multiple aperture devices.
Gang GJ; Mao A; Wang W; Siewerdsen JH; Mathews A; Kawamoto S; Levinson R; Stayman JW
Phys Med Biol; 2019 May; 64(10):105024. PubMed ID: 30939459
[TBL] [Abstract][Full Text] [Related]
3. Fluence-Field Modulated X-ray CT using Multiple Aperture Devices.
Stayman JW; Mathews A; Zbijewski W; Gang G; Siewerdsen J; Kawamoto S; Blevis I; Levinson R
Proc SPIE Int Soc Opt Eng; 2016 Feb; 9783():. PubMed ID: 27110052
[TBL] [Abstract][Full Text] [Related]
4. Experimental evaluation of dual Multiple Aperture Devices for Fluence Field Modulated X-Ray Computed Tomography.
Mathews AJ; Gang G; Levinson R; Zbijewski W; Kawamoto S; Siewerdsen JH; Stayman JW
Proc SPIE Int Soc Opt Eng; 2017 Feb; 10132():. PubMed ID: 28603335
[TBL] [Abstract][Full Text] [Related]
5. Implementation and Assessment of Dynamic Fluence Field Modulation with Multiple Aperture Devices.
Gang GJ; Mao A; Siewerdsen JH; Stayman JW
Conf Proc Int Conf Image Form Xray Comput Tomogr; 2018 May; 2018():47-51. PubMed ID: 30506056
[TBL] [Abstract][Full Text] [Related]
6. Volume-of-interest imaging with dynamic fluence modulation using multiple aperture devices.
Wang W; Gang GJ; Siewerdsen JH; Levinson R; Kawamoto S; Stayman JW
J Med Imaging (Bellingham); 2019 Jul; 6(3):033504. PubMed ID: 31528659
[TBL] [Abstract][Full Text] [Related]
7. Dynamic fluence field modulation for miscentered patients in computed tomography.
Mao A; Gang GJ; Shyr W; Levinson R; Siewerdsen JH; Kawamoto S; Webster Stayman J
J Med Imaging (Bellingham); 2018 Oct; 5(4):043501. PubMed ID: 30397631
[TBL] [Abstract][Full Text] [Related]
8. Volume-of-interest CT imaging with dynamic beam filtering using multiple aperture devices.
Wang W; Gang GJ; Mao A; Sisniega A; Siewerdsen JH; Stayman JW
Conf Proc Int Conf Image Form Xray Comput Tomogr; 2018 May; 2018():213-217. PubMed ID: 30556060
[TBL] [Abstract][Full Text] [Related]
9. Compensator models for fluence field modulated computed tomography.
Bartolac S; Jaffray D
Med Phys; 2013 Dec; 40(12):121909. PubMed ID: 24320520
[TBL] [Abstract][Full Text] [Related]
10. Dynamic beam filtering for miscentered patients.
Mao A; Shyr W; Gang GJ; Stayman JW
Proc SPIE Int Soc Opt Eng; 2018 Feb; 10573():. PubMed ID: 29622854
[TBL] [Abstract][Full Text] [Related]
11. Volume-of-interest Imaging Using Multiple Aperture Devices.
Wang W; Gang GJ; Siewerdsen JH; Stayman JW
Proc SPIE Int Soc Opt Eng; 2019 Feb; 10948():. PubMed ID: 31057199
[TBL] [Abstract][Full Text] [Related]
12. Fluence field optimization for noise and dose objectives in CT.
Bartolac S; Graham S; Siewerdsen J; Jaffray D
Med Phys; 2011 Jul; 38 Suppl 1():S2. PubMed ID: 21978114
[TBL] [Abstract][Full Text] [Related]
13. Prediction of image noise contributions in proton computed tomography and comparison to measurements.
Dickmann J; Wesp P; Rädler M; Rit S; Pankuch M; Johnson RP; Bashkirov V; Schulte RW; Parodi K; Landry G; Dedes G
Phys Med Biol; 2019 Jul; 64(14):145016. PubMed ID: 31125986
[TBL] [Abstract][Full Text] [Related]
14. Technical Note: Sheet-based dynamic beam attenuator - A novel concept for dynamic fluence field modulation in x-ray CT.
Huck SM; Fung GSK; Parodi K; Stierstorfer K
Med Phys; 2019 Dec; 46(12):5528-5537. PubMed ID: 31348527
[TBL] [Abstract][Full Text] [Related]
15. Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.
Shunhavanich P; Hsieh SS; Pelc NJ
Med Phys; 2019 Jan; 46(1):127-139. PubMed ID: 30383310
[TBL] [Abstract][Full Text] [Related]
16. Task-driven optimization of CT tube current modulation and regularization in model-based iterative reconstruction.
Gang GJ; Siewerdsen JH; Webster Stayman J
Phys Med Biol; 2017 Jun; 62(12):4777-4797. PubMed ID: 28362638
[TBL] [Abstract][Full Text] [Related]
17. SU-F-BRCD-07: Experimental Validation of Fluence Field Modulation for Noise and Dose Management in CT.
Bartolac S; Jaffray D
Med Phys; 2012 Jun; 39(6Part20):3857. PubMed ID: 28517545
[TBL] [Abstract][Full Text] [Related]
18. Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection.
Kontson K; Jennings RJ
Med Phys; 2015 Sep; 42(9):5270-7. PubMed ID: 26328976
[TBL] [Abstract][Full Text] [Related]
19. Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner.
Persson M; Bujila R; Nowik P; Andersson H; Kull L; Andersson J; Bornefalk H; Danielsson M
Med Phys; 2016 Jul; 43(7):4398. PubMed ID: 27370155
[TBL] [Abstract][Full Text] [Related]
20. Experimental fluence-modulated proton computed tomography by pencil beam scanning.
Dedes G; Johnson RP; Pankuch M; Detrich N; Pols WMA; Rit S; Schulte RW; Parodi K; Landry G
Med Phys; 2018 Jul; 45(7):3287-3296. PubMed ID: 29786862
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]