196 related articles for article (PubMed ID: 28365541)
1. Fracture strength and probability of survival of narrow and extra-narrow dental implants after fatigue testing: In vitro and in silico analysis.
Bordin D; Bergamo ETP; Fardin VP; Coelho PG; Bonfante EA
J Mech Behav Biomed Mater; 2017 Jul; 71():244-249. PubMed ID: 28365541
[TBL] [Abstract][Full Text] [Related]
2. Influence of platform diameter in the reliability and failure mode of extra-short dental implants.
Bordin D; Bergamo ETP; Bonfante EA; Fardin VP; Coelho PG
J Mech Behav Biomed Mater; 2018 Jan; 77():470-474. PubMed ID: 29032313
[TBL] [Abstract][Full Text] [Related]
3. Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs.
Bordin D; Witek L; Fardin VP; Bonfante EA; Coelho PG
J Prosthodont; 2018 Aug; 27(7):659-664. PubMed ID: 27859976
[TBL] [Abstract][Full Text] [Related]
4. Failure Modes and Survival of Anterior Crowns Supported by Narrow Implant Systems.
Bergamo ETP; de Araújo-Júnior ENS; Lopes ACO; Coelho PG; Zahoui A; Benalcázar Jalkh EB; Bonfante EA
Biomed Res Int; 2020; 2020():1057846. PubMed ID: 32964016
[TBL] [Abstract][Full Text] [Related]
5. Effect of microthread presence and restoration design (screw versus cemented) in dental implant reliability and failure modes.
Almeida EO; Freitas Júnior AC; Bonfante EA; Rocha EP; Silva NR; Coelho PG
Clin Oral Implants Res; 2013 Feb; 24(2):191-6. PubMed ID: 22413873
[TBL] [Abstract][Full Text] [Related]
6. Survival Probability of Narrow and Standard-Diameter Implants with Different Implant-Abutment Connection Designs.
Freitas GP; Hirata R; Bonfante EA; Tovar N; Coelho PG
Int J Prosthodont; 2016; 29(2):179-85. PubMed ID: 26929961
[TBL] [Abstract][Full Text] [Related]
7. Reliability and failure modes of internal conical dental implant connections.
Freitas-Júnior AC; Almeida EO; Bonfante EA; Silva NR; Coelho PG
Clin Oral Implants Res; 2013 Feb; 24(2):197-202. PubMed ID: 22429387
[TBL] [Abstract][Full Text] [Related]
8. Mechanical testing of implant-supported anterior crowns with different implant/abutment connections.
Almeida EO; Freitas AC; Bonfante EA; Marotta L; Silva NR; Coelho PG
Int J Oral Maxillofac Implants; 2013; 28(1):103-8. PubMed ID: 23377054
[TBL] [Abstract][Full Text] [Related]
9. Implant-abutment fit influences the mechanical performance of single-crown prostheses.
Ramalho IS; Bergamo ETP; Witek L; Coelho PG; Lopes ACO; Bonfante EA
J Mech Behav Biomed Mater; 2020 Feb; 102():103506. PubMed ID: 31877515
[TBL] [Abstract][Full Text] [Related]
10. Reliability and failure modes of narrow implant systems.
Hirata R; Bonfante EA; Anchieta RB; Machado LS; Freitas G; Fardin VP; Tovar N; Coelho PG
Clin Oral Investig; 2016 Sep; 20(7):1505-13. PubMed ID: 26526325
[TBL] [Abstract][Full Text] [Related]
11. Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.
Freitas AC; Bonfante EA; Rocha EP; Silva NR; Marotta L; Coelho PG
Eur J Oral Sci; 2011 Aug; 119(4):323-30. PubMed ID: 21726295
[TBL] [Abstract][Full Text] [Related]
12. Biomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysis.
Freitas-Júnior AC; Rocha EP; Bonfante EA; Almeida EO; Anchieta RB; Martini AP; Assunção WG; Silva NR; Coelho PG
Dent Mater; 2012 Oct; 28(10):e218-28. PubMed ID: 22682782
[TBL] [Abstract][Full Text] [Related]
13. Reliability and failure modes of anterior single-unit implant-supported restorations.
Freitas AC; Bonfante EA; Martins LM; Silva NR; Marotta L; Coelho PG
Clin Oral Implants Res; 2012 Sep; 23(9):1005-11. PubMed ID: 22092676
[TBL] [Abstract][Full Text] [Related]
14. Mechanical evaluation of four narrow-diameter implant systems.
Hirata R; Bonfante EA; Machado LS; Tovar N; Coelho PG
Int J Prosthodont; 2014; 27(4):359-62. PubMed ID: 25010880
[TBL] [Abstract][Full Text] [Related]
15. Single geometry abutment for narrow and extra-narrow implant systems: Survival and failure modes.
Gutierres E; Bergamo ETP; Carvalho LF; Coelho PG; Campos TMB; Piza MMT; Lopes ACO; Benalcazar Jalkh EB; Bonfante EA
J Mech Behav Biomed Mater; 2023 Jul; 143():105872. PubMed ID: 37201226
[TBL] [Abstract][Full Text] [Related]
16. Probability of survival and stress distribution of narrow diameter implants with different implant-abutment taper angles.
Freitas MIM; Gomes RS; Ruggiero MM; Bergamo ETP; Bonfante EA; Marcello-Machado RM; Del Bel Cury AA
J Biomed Mater Res B Appl Biomater; 2022 Mar; 110(3):638-645. PubMed ID: 34559448
[TBL] [Abstract][Full Text] [Related]
17. Effect of implant-abutment connection design on reliability of crowns: regular vs. horizontal mismatched platform.
Freitas Júnior AC; Bonfante EA; Silva NR; Marotta L; Coelho PG
Clin Oral Implants Res; 2012 Sep; 23(9):1123-6. PubMed ID: 22092300
[TBL] [Abstract][Full Text] [Related]
18. Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems.
Delben JA; Barão VA; Ferreira MB; da Silva NR; Thompson VP; Assunção WG
Dent Mater; 2014 Apr; 30(4):408-16. PubMed ID: 24507998
[TBL] [Abstract][Full Text] [Related]
19. Mechanical Evaluation of Two Grades of Titanium Used in Implant Dentistry.
Hirata R; Bonfante EA; Machado LS; Tovar N; Coelho PG
Int J Oral Maxillofac Implants; 2015; 30(4):800-5. PubMed ID: 26252031
[TBL] [Abstract][Full Text] [Related]
20. Hydrothermal aging affects the three-dimensional fit and fatigue lifetime of zirconia abutments.
Bergamo ETP; Campos TMB; Lopes ACO; Cardoso KB; Gouvea MVR; de Araújo-Júnior ENS; Witek L; Gierthmühlen PC; Coelho PG; Benalcázar Jalkh EB; Zahoui A; de Carvalho LF; Bonfante EA
J Mech Behav Biomed Mater; 2021 Dec; 124():104832. PubMed ID: 34536801
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]