These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 28368937)

  • 1. Physician-Directed Versus Computerized Closed-Loop Control of Blood Pressure Using Phenylephrine in a Swine Model.
    Marques NR; Whitehead WE; Kallu UR; Kinsky MP; Funston JS; Wassar T; Khan MN; Milosch M; Jupiter D; Grigoriadis K; Kramer GC
    Anesth Analg; 2017 Jul; 125(1):110-116. PubMed ID: 28368937
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated Titration of Vasopressor Infusion Using a Closed-loop Controller: In Vivo Feasibility Study Using a Swine Model.
    Joosten A; Delaporte A; Alexander B; Su F; Creteur J; Vincent JL; Cannesson M; Rinehart J
    Anesthesiology; 2019 Mar; 130(3):394-403. PubMed ID: 30608239
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Closed-Loop Feedback Computer-Controlled Phenylephrine for Maintenance of Blood Pressure During Spinal Anesthesia for Cesarean Delivery: A Randomized Trial Comparing Automated Boluses Versus Infusion.
    Ngan Kee WD; Tam YH; Khaw KS; Ng FF; Lee SWY
    Anesth Analg; 2017 Jul; 125(1):117-123. PubMed ID: 28368936
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine.
    Ngan Kee WD; Khaw KS; Tam YH; Ng FF; Lee SW
    J Clin Monit Comput; 2017 Jun; 31(3):617-623. PubMed ID: 27139726
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A randomized controlled trial of variable rate phenylephrine infusion with rescue phenylephrine boluses versus rescue boluses alone on physician interventions during spinal anesthesia for elective cesarean delivery.
    Siddik-Sayyid SM; Taha SK; Kanazi GE; Aouad MT
    Anesth Analg; 2014 Mar; 118(3):611-8. PubMed ID: 24299932
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A randomised controlled trial comparing weight adjusted dose versus fixed dose prophylactic phenylephrine infusion on maintaining systolic blood pressure during caesarean section under spinal anaesthesia.
    Mwaura L; Mung'ayi V; Kabugi J; Mir S
    Afr Health Sci; 2016 Jun; 16(2):399-411. PubMed ID: 27605955
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for caesarean delivery.
    Ngan Kee WD; Khaw KS; Ng FF; Tam YH
    Br J Anaesth; 2013 Jan; 110(1):59-65. PubMed ID: 23015618
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study.
    Ngan Kee WD; Tam YH; Khaw KS; Ng FF; Critchley LA; Karmakar MK
    Anaesthesia; 2007 Dec; 62(12):1251-6. PubMed ID: 17991262
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Closed-loop double-vasopressor automated system vs manual bolus vasopressor to treat hypotension during spinal anaesthesia for caesarean section: a randomised controlled trial.
    Sng BL; Tan HS; Sia AT
    Anaesthesia; 2014 Jan; 69(1):37-45. PubMed ID: 24256483
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new sodium-nitroprusside-infusion controller for the regulation of arterial blood pressure.
    Ruiz R; Borches D; González A; Corral J
    Biomed Instrum Technol; 1993; 27(3):244-51. PubMed ID: 8513386
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A randomized double-blinded comparison of phenylephrine and ephedrine infusion combinations to maintain blood pressure during spinal anesthesia for cesarean delivery: the effects on fetal acid-base status and hemodynamic control.
    Ngan Kee WD; Lee A; Khaw KS; Ng FF; Karmakar MK; Gin T
    Anesth Analg; 2008 Oct; 107(4):1295-302. PubMed ID: 18806043
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Phenylephrine infusion versus bolus regimens during cesarean delivery under spinal anesthesia: a double-blind randomized clinical trial to assess hemodynamic changes.
    Doherty A; Ohashi Y; Downey K; Carvalho JC
    Anesth Analg; 2012 Dec; 115(6):1343-50. PubMed ID: 23011562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A double-blind, placebo-controlled trial of four fixed rate infusion regimens of phenylephrine for hemodynamic support during spinal anesthesia for cesarean delivery.
    Allen TK; George RB; White WD; Muir HA; Habib AS
    Anesth Analg; 2010 Nov; 111(5):1221-9. PubMed ID: 20495139
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery.
    Joosten A; Alexander B; Duranteau J; Taccone FS; Creteur J; Vincent JL; Cannesson M; Rinehart J
    Br J Anaesth; 2019 Oct; 123(4):430-438. PubMed ID: 31255290
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phenylephrine ameliorates cerebral cytotoxic edema and reduces cerebral infarction volume in a rat model of complete unilateral carotid artery occlusion with severe hypotension.
    Ishikawa S; Ito H; Yokoyama K; Makita K
    Anesth Analg; 2009 May; 108(5):1631-7. PubMed ID: 19372348
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of closed-loop anesthesia delivery for propofol anesthesia in pediatric cardiac surgery.
    Biswas I; Mathew PJ; Singh RS; Puri GD
    Paediatr Anaesth; 2013 Dec; 23(12):1145-52. PubMed ID: 24118468
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Multicenter Evaluation of a Closed-Loop Anesthesia Delivery System: A Randomized Controlled Trial.
    Puri GD; Mathew PJ; Biswas I; Dutta A; Sood J; Gombar S; Palta S; Tsering M; Gautam PL; Jayant A; Arora I; Bajaj V; Punia TS; Singh G
    Anesth Analg; 2016 Jan; 122(1):106-14. PubMed ID: 25902324
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac output changes with phenylephrine and ephedrine infusions during spinal anesthesia for cesarean section: A randomized, double-blind trial.
    Mon W; Stewart A; Fernando R; Ashpole K; El-Wahab N; MacDonald S; Tamilselvan P; Columb M; Liu YM
    J Clin Anesth; 2017 Feb; 37():43-48. PubMed ID: 28235526
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficacy of Bolus-dose Phenylephrine for Peri-intubation Hypotension.
    Panchal AR; Satyanarayan A; Bahadir JD; Hays D; Mosier J
    J Emerg Med; 2015 Oct; 49(4):488-94. PubMed ID: 26104846
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists.
    Rinehart J; Chung E; Canales C; Cannesson M
    J Cardiothorac Vasc Anesth; 2012 Oct; 26(5):933-9. PubMed ID: 22795172
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.