167 related articles for article (PubMed ID: 28370852)
1. Prospective Study of the Use of Intraoperative Neuromonitoring in Determining Post-Operative Energy Requirements and Physiologic Midline in Spinal Cord Stimulation.
Collison C; Prusik J; Paniccioli S; Briotte M; Grey R; Feustel P; Pilitsis JG
Neuromodulation; 2017 Aug; 20(6):575-581. PubMed ID: 28370852
[TBL] [Abstract][Full Text] [Related]
2. Prospective Six-Month Analysis of Multiarea Burst Spinal Cord Stimulation: Correlating Intraoperative Neuromonitoring With Postoperative Programming and Clinical Outcomes.
Falowski SM; Nanivadekar AC
Neuromodulation; 2024 Jul; 27(5):899-907. PubMed ID: 38520459
[TBL] [Abstract][Full Text] [Related]
3. Intraoperative Neuromonitoring in Percutaneous Spinal Cord Stimulator Placement.
Hwang R; Field N; Kumar V; Paniccioli S; Grey R; Briotte M; Sukul V; Pilitsis JG
Neuromodulation; 2019 Apr; 22(3):341-346. PubMed ID: 30444284
[TBL] [Abstract][Full Text] [Related]
4. A Prospective Study of the Intra- and Postoperative Efficacy of Intraoperative Neuromonitoring in Spinal Cord Stimulation.
Roth SG; Lange S; Haller J; De La Cruz P; Kumar V; Wilock M; Paniccioli S; Briotte M; Pilitsis JG
Stereotact Funct Neurosurg; 2015; 93(5):348-54. PubMed ID: 26444517
[TBL] [Abstract][Full Text] [Related]
5. Intraoperative electrophysiological monitoring for C1-2 spinal cord stimulation.
Muncie LM; Ellens NR; Tolod-Kemp E; Feler CA; Winestone JS
J Neurosurg Spine; 2017 Feb; 26(2):183-189. PubMed ID: 27689422
[TBL] [Abstract][Full Text] [Related]
6. Intraoperative electromyography as an adjunct to sacral neuromodulation for chronic pelvic pain.
Taghva A; Romer J; Barolat G
Neuromodulation; 2015 Jan; 18(1):62-6; discussion 66. PubMed ID: 24954364
[TBL] [Abstract][Full Text] [Related]
7. Paresthesia-Independence: An Assessment of Technical Factors Related to 10 kHz Paresthesia-Free Spinal Cord Stimulation.
De Carolis G; Paroli M; Tollapi L; Doust MW; Burgher AH; Yu C; Yang T; Morgan DM; Amirdelfan K; Kapural L; Sitzman BT; Bundschu R; Vallejo R; Benyamin RM; Yearwood TL; Gliner BE; Powell AA; Bradley K
Pain Physician; 2017 May; 20(4):331-341. PubMed ID: 28535555
[TBL] [Abstract][Full Text] [Related]
8. The Use of Intraoperative Electromyogram During Spinal Cord Stimulator Placement Surgery: A Case Series.
Schoen N; Chieng LO; Madhavan K; Jermakowicz WJ; Vanni S
World Neurosurg; 2017 Apr; 100():74-84. PubMed ID: 28034811
[TBL] [Abstract][Full Text] [Related]
9. The Franco-Canadian multicolumn spinal cord stimulation prospective study: a subgroup analysis focusing on the decisive role of lead positioning.
Delmotte A; Jacques L; Kumar K; Poon K; Monlezun O; Roulaud M; Prevost A; Munson R; Guetarni F; Bataille B; Rigoard P
Neurochirurgie; 2015 Mar; 61 Suppl 1():S83-9. PubMed ID: 25245918
[TBL] [Abstract][Full Text] [Related]
10. Intraoperative Motor Evoked Responses to Double-Train Paradigm Stimulation for Guiding Lead Placement and Postoperative Programming in Spinal Cord Stimulation for Pain.
Schlaeppi JA; Schreen R; Mija R; Nowacki A; Pollo C; Seidel K
Neuromodulation; 2023 Jan; 26(1):147-156. PubMed ID: 35599160
[TBL] [Abstract][Full Text] [Related]
11. Regional Coverage Differences With Single- and Multi-Area Burst Spinal Cord Stimulation for Treatment of Chronic Pain.
Falowski SM; Benison AM; Nanivadekar AC
Neuromodulation; 2023 Oct; 26(7):1471-1477. PubMed ID: 36870935
[TBL] [Abstract][Full Text] [Related]
12. 10 kHz High-Frequency Spinal Cord Stimulation for Chronic Thoracic Pain: A Multicenter Case Series and a Guide for Optimal Anatomic Lead Placement.
Sayed D; Foster J; Nairizi A; Sills S; Miller A
Pain Physician; 2020 Jul; 23(4):E369-E376. PubMed ID: 32709183
[TBL] [Abstract][Full Text] [Related]
13. A Prospective Multicenter Case Series Utilizing Intraoperative Neuromonitoring With Evoked Compound Action Potentials to Confirm Spinal Cord Stimulation Lead Placement.
Falowski SM; Kim CH; Obradovic M; Parker JL
Neuromodulation; 2022 Jul; 25(5):724-730. PubMed ID: 35088735
[TBL] [Abstract][Full Text] [Related]
14. Localization of cervical and cervicomedullary stimulation leads for pain treatment using median nerve somatosensory evoked potential collision testing.
Balzer JR; Tomycz ND; Crammond DJ; Habeych M; Thirumala PD; Urgo L; Moossy JJ
J Neurosurg; 2011 Jan; 114(1):200-5. PubMed ID: 20509731
[TBL] [Abstract][Full Text] [Related]
15. Implanter's Integrated Information (I3) System: An Aid for Spinal Cord Stimulation Procedures.
Meier K; Knudsen ALH; Boudreau SA; Sørensen JCH
Neuromodulation; 2019 Apr; 22(3):290-294. PubMed ID: 30325079
[TBL] [Abstract][Full Text] [Related]
16. An Observational Case Series of Spinal Cord Stimulation Waveforms Visualized on Intraoperative Neuromonitoring.
Falowski SM
Neuromodulation; 2019 Feb; 22(2):219-228. PubMed ID: 29707900
[TBL] [Abstract][Full Text] [Related]
17. Nonawake vs Awake Placement of Spinal Cord Stimulators: A Prospective, Multicenter Study Comparing Safety and Efficacy.
Falowski SM; Sharan A; McInerney J; Jacobs D; Venkatesan L; Agnesi F
Neurosurgery; 2019 Jan; 84(1):198-205. PubMed ID: 29547957
[TBL] [Abstract][Full Text] [Related]
18. Electrophysiological Guidance of Epidural Electrode Array Implantation over the Human Lumbosacral Spinal Cord to Enable Motor Function after Chronic Paralysis.
Calvert JS; Grahn PJ; Strommen JA; Lavrov IA; Beck LA; Gill ML; Linde MB; Brown DA; Van Straaten MG; Veith DD; Lopez C; Sayenko DG; Gerasimenko YP; Edgerton VR; Zhao KD; Lee KH
J Neurotrauma; 2019 May; 36(9):1451-1460. PubMed ID: 30430902
[TBL] [Abstract][Full Text] [Related]
19. Anatomic Lead Placement Without Paresthesia Mapping Provides Effective and Predictable Therapy During the Trial Evaluation Period: Results From the Prospective, Multicenter, Randomized, DELIVERY Study.
Pope JE; Schu S; Sayed D; Raslan AM; Baranidharan G; Heros RD; Blomme B; Capobianco RA; Deer TR
Neuromodulation; 2020 Jan; 23(1):109-117. PubMed ID: 31323175
[TBL] [Abstract][Full Text] [Related]
20. Electrophysiologic monitoring for placement of laminectomy leads for spinal cord stimulation under general anesthesia.
Air EL; Toczyl GR; Mandybur GT
Neuromodulation; 2012; 15(6):573-9; discussion 579-80. PubMed ID: 23205816
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]