These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 28372433)

  • 41. Nontarget analysis of urine by electrospray ionization-high field asymmetric waveform ion mobility-tandem mass spectrometry.
    Beach DG; Gabryelski W
    Anal Chem; 2011 Dec; 83(23):9107-13. PubMed ID: 21978137
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Differential mobility separation of ions using a rectangular asymmetric waveform.
    Papanastasiou D; Wollnik H; Rico G; Tadjimukhamedov F; Mueller W; Eiceman GA
    J Phys Chem A; 2008 Apr; 112(16):3638-45. PubMed ID: 18338877
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Enhanced analyte detection using in-source fragmentation of field asymmetric waveform ion mobility spectrometry-selected ions in combination with time-of-flight mass spectrometry.
    Brown LJ; Smith RW; Toutoungi DE; Reynolds JC; Bristow AW; Ray A; Sage A; Wilson ID; Weston DJ; Boyle B; Creaser CS
    Anal Chem; 2012 May; 84(9):4095-103. PubMed ID: 22455620
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Application of effective potential approach to ion dynamics investigation in field asymmetric ion mobility spectrometry conditions.
    Nikolaev EN; Vedenov AA
    Eur J Mass Spectrom (Chichester); 2009; 15(2):343-8. PubMed ID: 19423919
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Combined corona discharge and UV photoionization source for ion mobility spectrometry.
    Bahrami H; Tabrizchi M
    Talanta; 2012 Aug; 97():400-5. PubMed ID: 22841099
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Terbutaline enantiomer separation and quantification by complexation and field asymmetric ion mobility spectrometry-tandem mass spectrometry.
    Mie A; Ray A; Axelsson BO; Jörntén-Karlsson M; Reimann CT
    Anal Chem; 2008 Jun; 80(11):4133-40. PubMed ID: 18447322
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS).
    Kolakowski BM; Mester Z
    Analyst; 2007 Sep; 132(9):842-64. PubMed ID: 17710259
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A compact high resolution ion mobility spectrometer for fast trace gas analysis.
    Kirk AT; Allers M; Cochems P; Langejuergen J; Zimmermann S
    Analyst; 2013 Sep; 138(18):5200-7. PubMed ID: 23678483
    [TBL] [Abstract][Full Text] [Related]  

  • 49. High-field asymmetric waveform ion mobility spectrometry for determining the location of in-source collision-induced dissociation in electrospray ionization mass spectrometry.
    Xia YQ; Jemal M
    Anal Chem; 2009 Sep; 81(18):7839-43. PubMed ID: 19691295
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A low noise and high precision linear power supply with thermal foldback protection.
    Carniti P; Cassina L; Gotti C; Maino M; Pessina G
    Rev Sci Instrum; 2016 May; 87(5):054706. PubMed ID: 27250450
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Direct analysis in real time coupled to multiplexed drift tube ion mobility spectrometry for detecting toxic chemicals.
    Harris GA; Kwasnik M; Fernández FM
    Anal Chem; 2011 Mar; 83(6):1908-15. PubMed ID: 21319810
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Compensation voltage shifting in high-field asymmetric waveform ion mobility spectrometry-mass spectrometry.
    Kolakowski BM; McCooeye MA; Mester Z
    Rapid Commun Mass Spectrom; 2006; 20(22):3319-29. PubMed ID: 17044119
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A Low-Noise CMOS THz Imager Based on Source Modulation and an In-Pixel High-Q Passive Switched-Capacitor N-Path Filter.
    Boukhayma A; Dupret A; Rostaing JP; Enz C
    Sensors (Basel); 2016 Mar; 16(3):. PubMed ID: 26950131
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Precise determination of nonlinear function of ion mobility for explosives and drugs at high electric fields for microchip FAIMS.
    Guo D; Wang Y; Li L; Wang X; Luo J
    J Mass Spectrom; 2015 Jan; 50(1):198-205. PubMed ID: 25601693
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Online nanoelectrospray/high-field asymmetric waveform ion mobility spectrometry as a potential tool for discovery pharmaceutical bioanalysis.
    Hatsis P; Valaskovic G; Wu JT
    Rapid Commun Mass Spectrom; 2009 Dec; 23(23):3736-42. PubMed ID: 19902415
    [TBL] [Abstract][Full Text] [Related]  

  • 56. A Low-Noise Amplifier for Submarine Electric Field Signal Based on Chopping Amplification Technology.
    Liu F; Chun S; Chen R; Xu C; Cao X
    Sensors (Basel); 2024 Feb; 24(5):. PubMed ID: 38474950
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Active sampling system for gas-phase analyzers.
    Akmalov AE; Chistyakov AA; Dubkova OI; Kotkovskii GE; Sychev AV
    Eur J Mass Spectrom (Chichester); 2017 Aug; 23(4):130-135. PubMed ID: 29028394
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Distortion of ion structures by field asymmetric waveform ion mobility spectrometry.
    Shvartsburg AA; Li F; Tang K; Smith RD
    Anal Chem; 2007 Feb; 79(4):1523-8. PubMed ID: 17297950
    [TBL] [Abstract][Full Text] [Related]  

  • 59. High-field asymmetric waveform ion mobility spectrometry coupled with liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-FAIMS-MS/MS) multi-component bioanalytical method development, performance evaluation and demonstration of the constancy of the compensation voltage with change of mobile phase composition or flow rate.
    Wu ST; Xia YQ; Jemal M
    Rapid Commun Mass Spectrom; 2007; 21(22):3667-76. PubMed ID: 17939154
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Enhanced performance in the determination of ibuprofen 1-β-O-acyl glucuronide in urine by combining high field asymmetric waveform ion mobility spectrometry with liquid chromatography-time-of-flight mass spectrometry.
    Smith RW; Toutoungi DE; Reynolds JC; Bristow AW; Ray A; Sage A; Wilson ID; Weston DJ; Boyle B; Creaser CS
    J Chromatogr A; 2013 Feb; 1278():76-81. PubMed ID: 23336944
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.