146 related articles for article (PubMed ID: 28372556)
1. A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis.
Fauziah K; Go KW; Ghazali A; Zaki M; Lim TO
BMC Nephrol; 2017 Apr; 18(1):123. PubMed ID: 28372556
[TBL] [Abstract][Full Text] [Related]
2. The dynamics of the metabolism of acetate and bicarbonate associated with use of hemodialysates in the ABChD trial: a phase IV, prospective, single center, single blind, randomized, cross-over, two week investigation.
Smith WB; Gibson S; Newman GE; Hendon KS; Askelson M; Zhao J; Hantash J; Flanagan B; Larkin JW; Usvyat LA; Thadhani RI; Maddux FW
BMC Nephrol; 2017 Aug; 18(1):273. PubMed ID: 28851317
[TBL] [Abstract][Full Text] [Related]
3. Dialysate bath and QTc interval in patients on chronic maintenance hemodialysis: pilot study of single dialysis effects.
Di Iorio B; Torraca S; Piscopo C; Sirico ML; Di Micco L; Pota A; Tartaglia D; Berardino L; Morrone LF; Russo D
J Nephrol; 2012; 25(5):653-60. PubMed ID: 21983985
[TBL] [Abstract][Full Text] [Related]
4. The faster potassium-lowering effect of high dialysate bicarbonate concentrations in chronic haemodialysis patients.
Heguilén RM; Sciurano C; Bellusci AD; Fried P; Mittelman G; Rosa Diez G; Bernasconi AR
Nephrol Dial Transplant; 2005 Mar; 20(3):591-7. PubMed ID: 15687112
[TBL] [Abstract][Full Text] [Related]
5. Calcium mass balances during standard bicarbonate hemodialysis and long-hour slow-flow bicarbonate hemodialysis.
Basile C; Libutti P; Di Turo AL; Tundo S; Maselli P; Casucci F; Losurdo N; Teutonico A; Vernaglione L; Lomonte C
J Nephrol; 2011; 24(6):742-8. PubMed ID: 21360470
[TBL] [Abstract][Full Text] [Related]
6. Bacteria and endotoxin removal from bicarbonate dialysis fluids for use in conventional, high-efficiency, and high-flux hemodialysis.
Oliver JC; Bland LA; Oettinger CW; Arduino MJ; Garrard M; Pegues DA; McAllister S; Moone T; Aguero S; Favero MS
Artif Organs; 1992 Apr; 16(2):141-5. PubMed ID: 10078235
[TBL] [Abstract][Full Text] [Related]
7. Glucose-added dialysis fluid prevents asymptomatic hypoglycaemia in regular haemodialysis.
Burmeister JE; Scapini A; da Rosa Miltersteiner D; da Costa MG; Campos BM
Nephrol Dial Transplant; 2007 Apr; 22(4):1184-9. PubMed ID: 17272314
[TBL] [Abstract][Full Text] [Related]
8. Accidental acute metabolic acidosis due to inappropriate selection of bicarbonate concentrate.
Golphinopoulos S; Oustabasidou N; Liakopoulos V; Kiropoulos T; Stefanidis I
EDTNA ERCA J; 2005; 31(2):85-7. PubMed ID: 16180553
[TBL] [Abstract][Full Text] [Related]
9. Three-Stream, Bicarbonate-Based Hemodialysis Solution Delivery System Revisited: With an Emphasis on Some Aspects of Acid-Base Principles.
Lew SQ; Kohn OF; Cheng YL; Kjellstrand CM; Ing TS
Artif Organs; 2017 Jun; 41(6):509-518. PubMed ID: 28574225
[TBL] [Abstract][Full Text] [Related]
10. Effect of Bicarbonate-Buffered Dialysate on Ventricular Arrhythmias in Hemodialysis Patients.
Krahn RE; Tulowitzki R; Gudleski GD; Murray B; Rajagopalan B; Su W; Muscarella M; Lambert J; Curtis AB; Panesar M
Am J Nephrol; 2019; 49(1):74-80. PubMed ID: 30602157
[TBL] [Abstract][Full Text] [Related]
11. Avoiding harm and achieving optimal dialysis outcomes--the dialysate component.
Spiegel DM
Adv Chronic Kidney Dis; 2012 May; 19(3):166-70. PubMed ID: 22578676
[TBL] [Abstract][Full Text] [Related]
12. [A comparative assessment of homeostasis and hemodynamics during the performance of bicarbonate and acetate hemodialysis].
Dzhavad-Zade MD; Agaev MM; Gamidov IM
Urol Nefrol (Mosk); 1991; (3):48-52. PubMed ID: 1871924
[TBL] [Abstract][Full Text] [Related]
13. Alkali delivery in chronic hemodialysis: Would more acetate be helpful?
Uribarri J; Oh MS
Semin Dial; 2019 May; 32(3):229-231. PubMed ID: 30937978
[TBL] [Abstract][Full Text] [Related]
14. Short-Term Effects of Branched-Chain Amino Acids-Enriched Dialysis Fluid on Branched-Chain Amino Acids Plasma Level and Mass Balance: A Randomized Cross-Over Study.
Deleaval P; Luaire B; Laffay P; Jambut-Cadon D; Stauss-Grabo M; Canaud B; Chazot C
J Ren Nutr; 2020 Jan; 30(1):61-68. PubMed ID: 31078402
[TBL] [Abstract][Full Text] [Related]
15. A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin.
Pegues DA; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Gordon SM; Favero MS; Jarvis WR
J Am Soc Nephrol; 1992 Oct; 3(4):1002-7. PubMed ID: 1450362
[TBL] [Abstract][Full Text] [Related]
16. Effects of low sodium dialysate in chronic hemodialysis patients: an echocardiographic study.
Sayarlioglu H; Erkoc R; Tuncer M; Soyoral Y; Esen R; Gumrukcuoglu HA; Dogan E; Sayarlioglu M
Ren Fail; 2007; 29(2):143-6. PubMed ID: 17365927
[TBL] [Abstract][Full Text] [Related]
17. High-flux dialyzers, backfiltration, and dialysis fluid quality.
Schiffl H
Semin Dial; 2011; 24(1):1-4. PubMed ID: 21299628
[TBL] [Abstract][Full Text] [Related]
18. [Bicarbonate hemodialysis in the therapy of chronic kidney failure].
Riabov SI; Shostka GD; Spiridonov VN; Vasil'ev AN; Kozlov VV
Ter Arkh; 1988; 60(5):76-80. PubMed ID: 3175934
[TBL] [Abstract][Full Text] [Related]
19. A four-stream method for providing variable dialysis fluid bicarbonate concentrations for bicarbonate-based dialysis fluid delivery systems.
Lew SQ; Sam R; Tzamaloukas AH; Ing TS
Artif Organs; 2021 Dec; 45(12):1576-1581. PubMed ID: 34637152
[TBL] [Abstract][Full Text] [Related]
20. Effect of dialysate bicarbonate and sodium on blood pH in maintenance hemodialysis-A prospective study.
Sridhar NR; Chen Z; Yu G; Lambert J; Muscarella M; Nanjundegowda M; Panesar M
Ther Apher Dial; 2023 Apr; 27(2):270-277. PubMed ID: 36056807
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]