307 related articles for article (PubMed ID: 28375560)
1. Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation.
Bousse A; Manber R; Holman BF; Atkinson D; Arridge S; Ourselin S; Hutton BF; Thielemans K
Med Phys; 2017 Jun; 44(6):2379-2390. PubMed ID: 28375560
[TBL] [Abstract][Full Text] [Related]
2. Maximum-Likelihood Joint Image Reconstruction/Motion Estimation in Attenuation-Corrected Respiratory Gated PET/CT Using a Single Attenuation Map.
Bousse A; Bertolli O; Atkinson D; Arridge S; Ourselin S; Hutton BF; Thielemans K
IEEE Trans Med Imaging; 2016 Jan; 35(1):217-28. PubMed ID: 26259017
[TBL] [Abstract][Full Text] [Related]
3. 4-Dimensional MRI and Attenuation Map Generation in PET/MRI with 4-Dimensional PET-Derived Deformation Matrices: Study of Feasibility for Lung Cancer Applications.
Fayad H; Schmidt H; Küstner T; Visvikis D
J Nucl Med; 2017 May; 58(5):833-839. PubMed ID: 27738008
[TBL] [Abstract][Full Text] [Related]
4. Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data.
Lu Y; Fontaine K; Mulnix T; Onofrey JA; Ren S; Panin V; Jones J; Casey ME; Barnett R; Kench P; Fulton R; Carson RE; Liu C
J Nucl Med; 2018 Sep; 59(9):1480-1486. PubMed ID: 29439015
[TBL] [Abstract][Full Text] [Related]
5. Maximum-likelihood joint image reconstruction and motion estimation with misaligned attenuation in TOF-PET/CT.
Bousse A; Bertolli O; Atkinson D; Arridge S; Ourselin S; Hutton BF; Thielemans K
Phys Med Biol; 2016 Feb; 61(3):L11-9. PubMed ID: 26789205
[TBL] [Abstract][Full Text] [Related]
6. Attenuation correction in 4D-PET using a single-phase attenuation map and rigidity-adaptive deformable registration.
Kalantari F; Wang J
Med Phys; 2017 Feb; 44(2):522-532. PubMed ID: 27987223
[TBL] [Abstract][Full Text] [Related]
7. Investigation of practical initial attenuation image estimates in TOF-MLAA reconstruction for PET/MR.
Cheng JC; Salomon A; Yaqub M; Boellaard R
Med Phys; 2016 Jul; 43(7):4163. PubMed ID: 27370136
[TBL] [Abstract][Full Text] [Related]
8. Impact of Tissue Classification in MRI-Guided Attenuation Correction on Whole-Body Patlak PET/MRI.
Zhuang M; Karakatsanis NA; Dierckx RAJO; Zaidi H
Mol Imaging Biol; 2019 Dec; 21(6):1147-1156. PubMed ID: 30838550
[TBL] [Abstract][Full Text] [Related]
9. MR-based attenuation correction using ultrashort-echo-time pulse sequences in dementia patients.
Cabello J; Lukas M; Förster S; Pyka T; Nekolla SG; Ziegler SI
J Nucl Med; 2015 Mar; 56(3):423-9. PubMed ID: 25678486
[TBL] [Abstract][Full Text] [Related]
10. PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data.
Fuin N; Pedemonte S; Catalano OA; Izquierdo-Garcia D; Soricelli A; Salvatore M; Heberlein K; Hooker JM; Van Leemput K; Catana C
J Nucl Med; 2017 May; 58(5):840-845. PubMed ID: 28126884
[TBL] [Abstract][Full Text] [Related]
11. Scattered PET data for attenuation-map reconstruction in PET/MRI.
Berker Y; Kiessling F; Schulz V
Med Phys; 2014 Oct; 41(10):102502. PubMed ID: 25281977
[TBL] [Abstract][Full Text] [Related]
12. MRI-assisted dual motion correction for myocardial perfusion defect detection in PET imaging.
Wang X; Rahmim A; Tang J
Med Phys; 2017 Sep; 44(9):4536-4547. PubMed ID: 28646593
[TBL] [Abstract][Full Text] [Related]
13. Generation of PET Attenuation Map for Whole-Body Time-of-Flight
Hwang D; Kang SK; Kim KY; Seo S; Paeng JC; Lee DS; Lee JS
J Nucl Med; 2019 Aug; 60(8):1183-1189. PubMed ID: 30683763
[TBL] [Abstract][Full Text] [Related]
14. Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI.
Mehranian A; Arabi H; Zaidi H
Neuroimage; 2016 Apr; 130():123-133. PubMed ID: 26853602
[TBL] [Abstract][Full Text] [Related]
15. Data-driven respiratory phase-matched PET attenuation correction without CT.
Hwang D; Kang SK; Kim KY; Choi H; Seo S; Lee JS
Phys Med Biol; 2021 May; 66(11):. PubMed ID: 33910170
[TBL] [Abstract][Full Text] [Related]
16. Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications.
Fayad H; Schmidt H; Wuerslin C; Visvikis D
J Nucl Med; 2015 Jun; 56(6):884-9. PubMed ID: 25908830
[TBL] [Abstract][Full Text] [Related]
17. PET attenuation correction using synthetic CT from ultrashort echo-time MR imaging.
Roy S; Wang WT; Carass A; Prince JL; Butman JA; Pham DL
J Nucl Med; 2014 Dec; 55(12):2071-7. PubMed ID: 25413135
[TBL] [Abstract][Full Text] [Related]
18. Joint cardiac and respiratory motion estimation for motion-corrected cardiac PET-MR.
Kolbitsch C; Neji R; Fenchel M; Schuh A; Mallia A; Marsden P; Schaeffter T
Phys Med Biol; 2018 Dec; 64(1):015007. PubMed ID: 30566409
[TBL] [Abstract][Full Text] [Related]
19. MR-based respiratory and cardiac motion correction for PET imaging.
Küstner T; Schwartz M; Martirosian P; Gatidis S; Seith F; Gilliam C; Blu T; Fayad H; Visvikis D; Schick F; Yang B; Schmidt H; Schwenzer NF
Med Image Anal; 2017 Dec; 42():129-144. PubMed ID: 28800546
[TBL] [Abstract][Full Text] [Related]
20. Magnetic resonance-based attenuation correction for PET/MR hybrid imaging using continuous valued attenuation maps.
Navalpakkam BK; Braun H; Kuwert T; Quick HH
Invest Radiol; 2013 May; 48(5):323-32. PubMed ID: 23442772
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]