BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 28376262)

  • 21. Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT.
    Jiang B; Li N; Shi X; Zhang S; Li J; de Bock GH; Vliegenthart R; Xie X
    Radiology; 2022 Apr; 303(1):202-212. PubMed ID: 35040674
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Deep learning-enabled accurate normalization of reconstruction kernel effects on emphysema quantification in low-dose CT.
    Jin H; Heo C; Kim JH
    Phys Med Biol; 2019 Jul; 64(13):135010. PubMed ID: 31185463
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT.
    Xu Y; He W; Chen H; Hu Z; Li J; Zhang T
    Clin Radiol; 2013 Sep; 68(9):902-8. PubMed ID: 23706621
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.
    Shin CI; Kim SH; Lee ES; Lee DH; Hwang EJ; Chung SY; Lee JM; Han JK; Choi BI
    Radiology; 2014 Dec; 273(3):759-71. PubMed ID: 25010640
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Computed Tomography Image Quality Evaluation of a New Iterative Reconstruction Algorithm in the Abdomen (Adaptive Statistical Iterative Reconstruction-V) a Comparison With Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection Reconstructions.
    Goodenberger MH; Wagner-Bartak NA; Gupta S; Liu X; Yap RQ; Sun J; Tamm EP; Jensen CT
    J Comput Assist Tomogr; 2018; 42(2):184-190. PubMed ID: 28806318
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Airway quantification using adaptive statistical iterative reconstruction-V on wide-detector low-dose CT: a validation study on lung specimen.
    Zhang L; Li Z; Meng J; Xie X; Zhang H
    Jpn J Radiol; 2019 May; 37(5):390-398. PubMed ID: 30820822
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of Filtered Back Projection, Hybrid Iterative Reconstruction, Model-Based Iterative Reconstruction, and Virtual Monoenergetic Reconstruction Images at Both Low- and Standard-Dose Settings in Measurement of Emphysema Volume and Airway Wall Thickness: A CT Phantom Study.
    Kim C; Lee KY; Shin C; Kang EY; Oh YW; Ha M; Ko CS; Cha J
    Korean J Radiol; 2018; 19(4):809-817. PubMed ID: 29962888
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.
    So A; Imai Y; Nett B; Jackson J; Nett L; Hsieh J; Wisenberg G; Teefy P; Yadegari A; Islam A; Lee TY
    Med Phys; 2016 Aug; 43(8):4821. PubMed ID: 27487900
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Investigating the role of imaging factors in the variability of CT-based texture analysis metrics.
    Varghese BA; Cen SY; Jensen K; Levy J; Andersen HK; Schulz A; Lei X; Duddalwar VA; Goodenough DJ
    J Appl Clin Med Phys; 2024 Apr; 25(4):e14192. PubMed ID: 37962032
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Image Quality in Oncologic Chest Computerized Tomography With Iterative Reconstruction: A Phantom Study.
    Jensen K; Aaløkken TM; Tingberg A; Fosse E; Martinsen AC
    J Comput Assist Tomogr; 2016; 40(3):351-6. PubMed ID: 27192499
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of lung CT number and airway dimension evaluation capabilities of ultra-high-resolution CT, using different scan modes and reconstruction methods including deep learning reconstruction, with those of multi-detector CT in a QIBA phantom study.
    Ohno Y; Akino N; Fujisawa Y; Kimata H; Ito Y; Fujii K; Kataoka Y; Ida Y; Oshima Y; Hamabuchi N; Shigemura C; Watanabe A; Obama Y; Hanamatsu S; Ueda T; Ikeda H; Murayama K; Toyama H
    Eur Radiol; 2023 Jan; 33(1):368-379. PubMed ID: 35841417
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quantification of airway dimensions using a high-resolution CT scanner: A phantom study.
    Zhao Y; Hernandez AM; Boone JM; Molloi S
    Med Phys; 2021 Oct; 48(10):5874-5883. PubMed ID: 34287955
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen.
    Singh S; Kalra MK; Do S; Thibault JB; Pien H; O'Connor OJ; Blake MA
    J Comput Assist Tomogr; 2012; 36(3):347-53. PubMed ID: 22592622
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol.
    Klink T; Obmann V; Heverhagen J; Stork A; Adam G; Begemann P
    Eur J Radiol; 2014 Sep; 83(9):1645-54. PubMed ID: 25037931
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study.
    Mathieu KB; Ai H; Fox PS; Godoy MC; Munden RF; de Groot PM; Pan T
    J Appl Clin Med Phys; 2014 Mar; 15(2):4515. PubMed ID: 24710436
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Standardizing CT lung density measure across scanner manufacturers.
    Chen-Mayer HH; Fuld MK; Hoppel B; Judy PF; Sieren JP; Guo J; Lynch DA; Possolo A; Fain SB
    Med Phys; 2017 Mar; 44(3):974-985. PubMed ID: 28060414
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Sinogram Affirmed Iterative Reconstruction (SAFIRE) versus weighted filtered back projection (WFBP) effects on quantitative measure in the COPDGene 2 test object.
    Sieren JP; Hoffman EA; Fuld MK; Chan KS; Guo J; Newell JD
    Med Phys; 2014 Sep; 41(9):091910. PubMed ID: 25186397
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques.
    Singh S; Kalra MK; Hsieh J; Licato PE; Do S; Pien HH; Blake MA
    Radiology; 2010 Nov; 257(2):373-83. PubMed ID: 20829535
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT.
    Jia Y; Ji X; He T; Yu Y; Yu N; Duan H; Guo Y
    Acad Radiol; 2018 Dec; 25(12):1526-1532. PubMed ID: 30017502
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology.
    Samei E; Richard S
    Med Phys; 2015 Jan; 42(1):314-23. PubMed ID: 25563271
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.