These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 28380995)

  • 1. Wavelength calibration of a high resolution spectrograph with a partially stabilized 15-GHz astrocomb from 550 to 890 nm.
    McCracken RA; Depagne É; Kuhn RB; Erasmus N; Crause LA; Reid DT
    Opt Express; 2017 Mar; 25(6):6450-6460. PubMed ID: 28380995
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous ultraviolet to blue-green astrocomb.
    Cheng YS; Dadi K; Mitchell T; Thompson S; Piskunov N; Wright LD; Gawith CBE; McCracken RA; Reid DT
    Nat Commun; 2024 Feb; 15(1):1466. PubMed ID: 38368423
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atomically referenced 1-GHz optical parametric oscillator frequency comb.
    McCracken RA; Balskus K; Zhang Z; Reid DT
    Opt Express; 2015 Jun; 23(12):16466-72. PubMed ID: 26193617
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Demonstration of on-sky calibration of astronomical spectra using a 25 GHz near-IR laser frequency comb.
    Ycas GG; Quinlan F; Diddams SA; Osterman S; Mahadevan S; Redman S; Terrien R; Ramsey L; Bender CF; Botzer B; Sigurdsson S
    Opt Express; 2012 Mar; 20(6):6631-43. PubMed ID: 22418547
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A 12.5 GHz-spaced optical frequency comb spanning >400 nm for near-infrared astronomical spectrograph calibration.
    Quinlan F; Ycas G; Osterman S; Diddams SA
    Rev Sci Instrum; 2010 Jun; 81(6):063105. PubMed ID: 20590223
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Broadband near-infrared astronomical spectrometer calibration and on-sky validation with an electro-optic laser frequency comb.
    Obrzud E; Rainer M; Harutyunyan A; Chazelas B; Cecconi M; Ghedina A; Molinari E; Kundermann S; Lecomte S; Pepe F; Wildi F; Bouchy F; Herr T
    Opt Express; 2018 Dec; 26(26):34830-34841. PubMed ID: 30650900
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Full stabilization and characterization of an optical frequency comb from a diode-pumped solid-state laser with GHz repetition rate.
    Hakobyan S; Wittwer VJ; Brochard P; Gürel K; Schilt S; Mayer AS; Keller U; Südmeyer T
    Opt Express; 2017 Aug; 25(17):20437-20453. PubMed ID: 29041725
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calibration of an astrophysical spectrograph below 1 m/s using a laser frequency comb.
    Phillips DF; Glenday AG; Li CH; Cramer C; Furesz G; Chang G; Benedick AJ; Chen LJ; Kärtner FX; Korzennik S; Sasselov D; Szentgyorgyi A; Walsworth RL
    Opt Express; 2012 Jun; 20(13):13711-26. PubMed ID: 22714437
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultraviolet astronomical spectrograph calibration with laser frequency combs from nanophotonic lithium niobate waveguides.
    Ludwig M; Ayhan F; Schmidt TM; Wildi T; Voumard T; Blum R; Ye Z; Lei F; Wildi F; Pepe F; Gaafar MA; Obrzud E; Grassani D; Hefti O; Karlen S; Lecomte S; Moreau F; Chazelas B; Sottile R; Torres-Company V; Brasch V; Villanueva LG; Bouchy F; Herr T
    Nat Commun; 2024 Sep; 15(1):7614. PubMed ID: 39223131
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Broadband Fourier-transform spectrometer enabling modal subset identification in Fabry-Pérot-based astrocombs.
    Charsley JM; McCracken RA; Reid L; Reid DT
    Opt Express; 2017 Aug; 25(16):19251-19262. PubMed ID: 29041118
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In-situ determination of astro-comb calibrator lines to better than 10 cm s(-1).
    Li CH; Glenday AG; Benedick AJ; Chang G; Chen LJ; Cramer C; Fendel P; Furesz G; Kärtner FX; Korzennik S; Phillips DF; Sasselov D; Szentgyorgyi A; Walsworth RL
    Opt Express; 2010 Jun; 18(12):13239-49. PubMed ID: 20588453
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 1-GHz harmonically pumped femtosecond optical parametric oscillator frequency comb.
    Balskus K; Leitch SM; Zhang Z; McCracken RA; Reid DT
    Opt Express; 2015 Jan; 23(2):1283-8. PubMed ID: 25835887
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of symmetric and asymmetric double quantum well extended-cavity diode lasers for broadband passive mode-locking at 780  nm.
    Christopher H; Kovalchuk EV; Wenzel H; Bugge F; Weyers M; Wicht A; Peters A; Tränkle G
    Appl Opt; 2017 Jul; 56(19):5566-5572. PubMed ID: 29047520
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A laser frequency comb that enables radial velocity measurements with a precision of 1 cm s(-1).
    Li CH; Benedick AJ; Fendel P; Glenday AG; Kärtner FX; Phillips DF; Sasselov D; Szentgyorgyi A; Walsworth RL
    Nature; 2008 Apr; 452(7187):610-2. PubMed ID: 18385734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Searching for Exoplanets Using a Microresonator Astrocomb.
    Suh MG; Yi X; Lai YH; Leifer S; Grudinin IS; Vasisht G; Martin EC; Fitzgerald MP; Doppmann G; Wang J; Mawet D; Papp SB; Diddams SA; Beichman C; Vahala K
    Nat Photonics; 2019; 13():25-30. PubMed ID: 30740138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Frequency-comb-referenced multi-channel fiber laser for DWDM communication.
    Chun BJ; Hyun S; Kim S; Kim SW; Kim YJ
    Opt Express; 2013 Dec; 21(24):29179-85. PubMed ID: 24514469
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A pulsated weak-resonant-cavity laser diode with transient wavelength scanning and tracking for injection-locked RZ transmission.
    Lin GR; Chi YC; Liao YS; Kuo HC; Liao ZW; Wang HL; Lin GC
    Opt Express; 2012 Jun; 20(13):13622-35. PubMed ID: 22714427
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Offset frequency dynamics and phase noise properties of a self-referenced 10 GHz Ti:sapphire frequency comb.
    Heinecke DC; Bartels A; Diddams SA
    Opt Express; 2011 Sep; 19(19):18440-51. PubMed ID: 21935212
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Compact, Ti:sapphire-based, methane-stabilized optical molecular frequency comb and clock.
    Benedick A; Tyurikov D; Gubin M; Shewmon R; Chuang I; Kärtner FX
    Opt Lett; 2009 Jul; 34(14):2168-70. PubMed ID: 19823537
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Precision spectroscopy using a partially stabilized frequency comb.
    Lyon M; Bergeson SD
    Appl Opt; 2014 Aug; 53(23):5163-8. PubMed ID: 25320925
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.