BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 28396901)

  • 1. [​Biomechanics of new implants for HTO].
    Pape D; Diffo Kaze A; Hoffmann A; Maas S
    Orthopade; 2017 Jul; 46(7):583-595. PubMed ID: 28396901
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy.
    Diffo Kaze A; Maas S; Waldmann D; Zilian A; Dueck K; Pape D
    J Exp Orthop; 2015 Dec; 2(1):14. PubMed ID: 26914882
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Static and fatigue strength of a novel anatomically contoured implant compared to five current open-wedge high tibial osteotomy plates.
    Diffo Kaze A; Maas S; Belsey J; Hoffmann A; Pape D
    J Exp Orthop; 2017 Dec; 4(1):39. PubMed ID: 29222607
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stability of two angular stable locking plates for open wedge high tibial osteotomy (HTO): TomoFix™ versus LOQTEQ® HTO plate.
    Petersen W; Wall A; Paulin T; Park HU; Heymann L
    Arch Orthop Trauma Surg; 2014 Oct; 134(10):1437-42. PubMed ID: 25015791
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical strength of a new plate compared to six previously tested opening wedge high tibial osteotomy implants.
    Diffo Kaze A; Maas S; Belsey J; Hoffmann A; Seil R; van Heerwaarden R; Pape D
    J Exp Orthop; 2019 Nov; 6(1):43. PubMed ID: 31701256
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate.
    Cotic M; Vogt S; Hinterwimmer S; Feucht MJ; Slotta-Huspenina J; Schuster T; Imhoff AB
    Knee Surg Sports Traumatol Arthrosc; 2015 Jul; 23(7):2032-40. PubMed ID: 24562634
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between two angular stable locking plates for medial opening-wedge high tibial osteotomy: Decisive wedge locking plate versus TomoFix™.
    Shin YS; Kim KH; Sim HB; Yoon JR
    J Orthop Sci; 2016 Nov; 21(6):791-797. PubMed ID: 27523262
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.
    Burchard R; Katerla D; Hammer M; Pahlkötter A; Soost C; Dietrich G; Ohrndorf A; Richter W; Lengsfeld M; Christ HJ; Graw JA; Fritzen CP
    Int Orthop; 2018 Aug; 42(8):1835-1843. PubMed ID: 29392383
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Placement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses.
    Luo CA; Hwa SY; Lin SC; Chen CM; Tseng CS
    BMC Musculoskelet Disord; 2015 Sep; 16():235. PubMed ID: 26337985
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical comparative study of five currently used implants for high tibial osteotomy: realistic loading including muscle forces versus simplified experimental loading.
    Diffo Kaze A; Maas S; Kedziora S; Belsey J; Haupert A; Wolf C; Hoffmann A; Pape D
    J Exp Orthop; 2018 Aug; 5(1):28. PubMed ID: 30091026
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of simple algorithms to predict screw length facilitates navigation-controlled medial opening-wedge osteotomy using the TomoFix HTO system.
    Kim TK; Chang CB; Lee KH; Cho HJ; Je MS; Won HH; Kang YG
    Orthopedics; 2012 Oct; 35(10 Suppl):22-8. PubMed ID: 23026248
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation.
    Chen YN; Chang CW; Li CT; Chen CH; Chung CR; Chang CH; Peng YT
    J Orthop Surg Res; 2019 Jan; 14(1):35. PubMed ID: 30691494
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Short-Term Clinical Outcomes of High Tibial Osteotomy with the iBalance HTO System.
    Thompson KA; Darden CN; Katsman A; Alaia MJ; Strauss EJ; Jazrawi LM
    Bull Hosp Jt Dis (2013); 2019 Dec; 77(4):256-262. PubMed ID: 31785139
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Factors affecting stability after medial opening wedge high tibial osteotomy using locking plate: A cadaveric study.
    Na YG; Kwak DS; Chong S; Kim TK
    Knee; 2019 Dec; 26(6):1313-1322. PubMed ID: 31443941
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating.
    Röderer G; Gebhard F; Duerselen L; Ignatius A; Claes L
    Injury; 2014 Oct; 45(10):1648-52. PubMed ID: 24813098
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy.
    Spahn G; Mückley T; Kahl E; Hofmann GO
    Clin Biomech (Bristol, Avon); 2006 Mar; 21(3):272-8. PubMed ID: 16337721
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases.
    Brosset T; Pasquier G; Migaud H; Gougeon F
    Orthop Traumatol Surg Res; 2011 Nov; 97(7):705-11. PubMed ID: 22001198
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study.
    Pape D; Lorbach O; Schmitz C; Busch LC; Van Giffen N; Seil R; Kohn DM
    Knee Surg Sports Traumatol Arthrosc; 2010 Feb; 18(2):204-11. PubMed ID: 19809806
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessing the local mechanical environment in medial opening wedge high tibial osteotomy using finite element analysis.
    Pauchard Y; Ivanov TG; McErlain DD; Milner JS; Giffin JR; Birmingham TB; Holdsworth DW
    J Biomech Eng; 2015 Mar; 137(3):. PubMed ID: 25363041
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical properties following open wedge high tibial osteotomy: Plate fixator combined with dynamic locking screws versus standard locking screws.
    Schröter S; Hoffmann T; Döbele S; Welke B; Hurschler C; Schwarze M; Stöckle U; Freude T; Ateschrang A
    Clin Biomech (Bristol, Avon); 2018 Dec; 60():108-114. PubMed ID: 30340150
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.