These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

352 related articles for article (PubMed ID: 28397410)

  • 1. Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.
    Glass K; Trivedi P; Wang S; Woitas K; Kunselman AR; Ündar A
    Artif Organs; 2017 Apr; 41(4):392-400. PubMed ID: 28397410
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.
    Shank KR; Profeta E; Wang S; O'Connor C; Kunselman AR; Woitas K; Myers JL; Ündar A
    Artif Organs; 2018 Apr; 42(4):365-376. PubMed ID: 28940550
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In Vitro Evaluation of an Alternative Neonatal Extracorporeal Life Support Circuit on Hemodynamic Performance and Bubble Trap.
    Spencer SB; Wang S; Woitas K; Glass K; Kunselman AR; Ündar A
    Artif Organs; 2017 Jan; 41(1):17-24. PubMed ID: 27735070
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach.
    Wang S; Caneo LF; Jatene MB; Jatene FB; Cestari IA; Kunselman AR; Ündar A
    Artif Organs; 2017 Sep; 41(9):865-874. PubMed ID: 28597590
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of neonatal membrane oxygenators with respect to gaseous microemboli capture and transmembrane pressure gradients.
    Qiu F; Guan Y; Su X; Kunselman A; Undar A
    Artif Organs; 2010 Nov; 34(11):923-9. PubMed ID: 21092035
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Potential Danger of Pre-Pump Clamping on Negative Pressure-Associated Gaseous Microemboli Generation During Extracorporeal Life Support--An In Vitro Study.
    Wang S; Chin BJ; Gentile F; Kunselman AR; Palanzo D; Ündar A
    Artif Organs; 2016 Jan; 40(1):89-94. PubMed ID: 26153848
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of conventional nonpulsatile and novel pulsatile extracorporeal life support systems in a simulated pediatric extracorporeal life support model.
    Wang S; Evenson A; Chin BJ; Kunselman AR; Ündar A
    Artif Organs; 2015 Jan; 39(1):E1-9. PubMed ID: 24660832
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Capiox RX25 and Quadrox-i Adult Hollow Fiber Membrane Oxygenators in a Simulated Cardiopulmonary Bypass Circuit.
    Wang S; Kunselman AR; Ündar A
    Artif Organs; 2016 May; 40(5):E69-78. PubMed ID: 27168381
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of Pulsatile Control Algorithms for Diagonal Pump on Hemodynamic Performance and Hemolysis.
    Wang S; Force M; Moroi MK; Patel S; Kunselman AR; Ündar A
    Artif Organs; 2019 Jan; 43(1):60-75. PubMed ID: 30374991
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In Vitro Comparison of Pediatric Oxygenators With and Without Integrated Arterial Filters in Maintaining Optimal Hemodynamic Stability and Managing Gaseous Microemboli.
    Moroi M; Force M; Wang S; Kunselman AR; Ündar A
    Artif Organs; 2018 Apr; 42(4):420-431. PubMed ID: 29377185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the Quadrox-I neonatal oxygenator with an integrated arterial filter.
    Salavitabar A; Qiu F; Kunselman A; Ündar A
    Perfusion; 2010 Nov; 25(6):409-15. PubMed ID: 20699287
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Extracorporeal life support systems: alternative vs. conventional circuits.
    Khan S; Vasavada R; Qiu F; Kunselman A; Undar A
    Perfusion; 2011 May; 26(3):191-8. PubMed ID: 21227982
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation and Comparison of Hemodynamic Performance of Three ECLS Systems in a Simulated Adult Cardiogenic Shock Model.
    Ündar A; Wang S; Moroi M; Kunselman AR; Brehm CE
    Artif Organs; 2018 Aug; 42(8):776-785. PubMed ID: 29575097
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In Vitro Comparison of Two Neonatal ECMO Circuits Using a Roller or Centrifugal Pump With Three Different In-Line Hemoconcentrators for Maintaining Hemodynamic Energy Delivery to the Patient.
    Force M; Moroi M; Wang S; Palanzo DA; Kunselman AR; Ündar A
    Artif Organs; 2018 Apr; 42(4):354-364. PubMed ID: 29323409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of HL-20 roller pump and Rotaflow centrifugal pump on perfusion quality and gaseous microemboli delivery.
    Yee S; Qiu F; Su X; Rider A; Kunselman AR; Guan Y; Undar A
    Artif Organs; 2010 Nov; 34(11):937-43. PubMed ID: 20946282
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of Hemodynamic Performance of a Combined ECLS and CRRT Circuit in Seven Positions With a Simulated Neonatal Patient.
    Profeta E; Shank K; Wang S; O'Connor C; Kunselman AR; Woitas K; Myers JL; Ündar A
    Artif Organs; 2018 Feb; 42(2):155-165. PubMed ID: 28621839
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.
    Guan Y; Palanzo D; Kunselman A; Undar A
    Artif Organs; 2009 Nov; 33(11):1037-43. PubMed ID: 19874280
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In-Vitro Evaluation of Two Types of Neonatal Oxygenators in Handling Gaseous Microemboli and Maintaining Optimal Hemodynamic Stability During Cardiopulmonary Bypass.
    Marupudi N; Wang S; Canêo LF; Jatene FB; Kunselman AR; Undar A
    Braz J Cardiovasc Surg; 2016; 31(5):343-350. PubMed ID: 27982342
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Does an Open Recirculation Line Affect the Flow Rate and Pressure in a Neonatal Extracorporeal Life Support Circuit With a Centrifugal or Roller Pump?
    Wang S; Spencer SB; Woitas K; Glass K; Kunselman AR; Ündar A
    Artif Organs; 2017 Jan; 41(1):70-75. PubMed ID: 27862035
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of pulsatile flow on hemodynamic energy in a Medos Deltastream DP3 pediatric extracorporeal life support system.
    Krawiec C; Wang S; Kunselman AR; Ündar A
    Artif Organs; 2014 Jan; 38(1):19-27. PubMed ID: 23826748
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.