176 related articles for article (PubMed ID: 28398596)
1. Small field dose measurements using plastic scintillation detector in heterogeneous media.
Xue J; McKay JD; Grimm J; Cheng CW; Berg R; Grimm SL; Xu Q; Subedi G; Das IJ
Med Phys; 2017 Jul; 44(7):3815-3820. PubMed ID: 28398596
[TBL] [Abstract][Full Text] [Related]
2. Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry.
Alagar AG; Mani GK; Karunakaran K
J Appl Clin Med Phys; 2016 Jan; 17(1):132-142. PubMed ID: 26894345
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.
Pasquino M; Cutaia C; Radici L; Valzano S; Gino E; Cavedon C; Stasi M
Br J Radiol; 2017 Jan; 90(1069):20160596. PubMed ID: 27826990
[TBL] [Abstract][Full Text] [Related]
4. Characterization of the exradin W1 plastic scintillation detector for small field applications in proton therapy.
Hoehr C; Lindsay C; Beaudry J; Penner C; Strgar V; Lee R; Duzenli C
Phys Med Biol; 2018 May; 63(9):095016. PubMed ID: 29634488
[TBL] [Abstract][Full Text] [Related]
5. The output factor correction as function of the photon beam field size - direct measurement and calculation from the lateral dose response functions of gas-filled and solid detectors.
Poppinga D; Delfs B; Meyners J; Harder D; Poppe B; Looe HK
Z Med Phys; 2018 Aug; 28(3):224-235. PubMed ID: 28869164
[TBL] [Abstract][Full Text] [Related]
6. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry.
Galavis PE; Hu L; Holmes S; Das IJ
Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221
[TBL] [Abstract][Full Text] [Related]
7. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
[TBL] [Abstract][Full Text] [Related]
8. The practical application of scintillation dosimetry in small-field photon-beam radiotherapy.
Burke E; Poppinga D; Schönfeld AA; Harder D; Poppe B; Looe HK
Z Med Phys; 2017 Dec; 27(4):324-333. PubMed ID: 28342596
[TBL] [Abstract][Full Text] [Related]
9. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
Moignier C; Huet C; Makovicka L
Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
[TBL] [Abstract][Full Text] [Related]
10. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
[TBL] [Abstract][Full Text] [Related]
11. Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy.
Alsanea F; Wootton L; Sahoo N; Kudchadker R; Mahmood U; Beddar S
Phys Med; 2018 Mar; 47():58-63. PubMed ID: 29609819
[TBL] [Abstract][Full Text] [Related]
12. Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife.
Wilcox EE; Daskalov GM
Med Phys; 2008 Jun; 35(6):2259-66. PubMed ID: 18649456
[TBL] [Abstract][Full Text] [Related]
13. Technical Note: Evaluation of plastic scintillator detector for small field stereotactic patient-specific quality assurance.
Qin Y; Gardner SJ; Kim J; Huang Y; Wen N; Doemer A; Chetty IJ
Med Phys; 2017 Oct; 44(10):5509-5516. PubMed ID: 28714067
[TBL] [Abstract][Full Text] [Related]
14. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
Benmakhlouf H; Sempau J; Andreo P
Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
[TBL] [Abstract][Full Text] [Related]
15. Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.
Qin Y; Zhong H; Wen N; Snyder K; Huang Y; Chetty IJ
J Appl Clin Med Phys; 2016 Nov; 17(6):379-391. PubMed ID: 27929510
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams.
Araki F
Phys Med Biol; 2012 Nov; 57(22):7615-27. PubMed ID: 23103477
[TBL] [Abstract][Full Text] [Related]
17. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
Papaconstadopoulos P; Archambault L; Seuntjens J
Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
[TBL] [Abstract][Full Text] [Related]
18. [Characterization of Small Volume Plastic Scintillation Detector].
Fukui Y; Hamada Y; Noma K; Harada N
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776
[TBL] [Abstract][Full Text] [Related]
19. Fabrication and characterization of a stemless plastic scintillation detector.
Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A
Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652
[TBL] [Abstract][Full Text] [Related]
20. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
Archambault L; Polf JC; Beaulieu L; Beddar S
Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]