BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 28398905)

  • 1. An integrated model of scintillator-reflector properties for advanced simulations of optical transport.
    Roncali E; Stockhoff M; Cherry SR
    Phys Med Biol; 2017 Jun; 62(12):4811-4830. PubMed ID: 28398905
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optimization of scintillator-reflector optical interfaces for the LUT Davis model.
    Trigila C; Roncali E
    Med Phys; 2021 Sep; 48(9):4883-4899. PubMed ID: 34287943
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Advanced optical simulation of scintillation detectors in GATE V8.0: first implementation of a reflectance model based on measured data.
    Stockhoff M; Jan S; Dubois A; Cherry SR; Roncali E
    Phys Med Biol; 2017 Jun; 62(12):L1-L8. PubMed ID: 28452339
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Technical Note: Standalone application to generate custom reflectance Look-Up Table for advanced optical Monte Carlo simulation in GATE/Geant4.
    Trigila C; Moghe E; Roncali E
    Med Phys; 2021 Jun; 48(6):2800-2808. PubMed ID: 33772816
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Integration of polarization in the LUTDavis model for optical Monte Carlo simulation in radiation detectors.
    Trigila C; Roncali E
    Phys Med Biol; 2021 Oct; 66(21):. PubMed ID: 34624869
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Identifying key surface parameters for optical photon transport in GEANT4/GATE simulations.
    Nilsson J; Cuplov V; Isaksson M
    Appl Radiat Isot; 2015 Sep; 103():15-24. PubMed ID: 26046519
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulation of light transport in scintillators based on 3D characterization of crystal surfaces.
    Roncali E; Cherry SR
    Phys Med Biol; 2013 Apr; 58(7):2185-98. PubMed ID: 23475145
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
    Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
    Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of light transport inside scintillation crystals for PET detectors.
    Yang X; Downie E; Farrell T; Peng H
    Phys Med Biol; 2013 Apr; 58(7):2143-61. PubMed ID: 23470488
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Predicting the timing properties of phosphor-coated scintillators using Monte Carlo light transport simulation.
    Roncali E; Schmall JP; Viswanath V; Berg E; Cherry SR
    Phys Med Biol; 2014 Apr; 59(8):2023-39. PubMed ID: 24694727
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Colored reflectors to improve coincidence timing resolution of BGO-based time-of-flight PET detectors.
    Lee D; Cherry SR; Kwon SI
    Phys Med Biol; 2023 Sep; 68(18):. PubMed ID: 37579768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager.
    Mosleh-Shirazi MA; Swindell W; Evans PM
    Med Phys; 1998 Oct; 25(10):1880-90. PubMed ID: 9800695
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation of scintillation light output in LYSO scintillators through a full factorial design.
    Loignon-Houle F; Bergeron M; Pepin CM; Charlebois SA; Lecomte R
    Phys Med Biol; 2017 Jan; 62(2):669-683. PubMed ID: 28050968
    [TBL] [Abstract][Full Text] [Related]  

  • 15. hybridMANTIS: a CPU-GPU Monte Carlo method for modeling indirect x-ray detectors with columnar scintillators.
    Sharma D; Badal A; Badano A
    Phys Med Biol; 2012 Apr; 57(8):2357-72. PubMed ID: 22469917
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A SiPM-based isotropic-3D PET detector X'tal cube with a three-dimensional array of 1 mm(3) crystals.
    Yamaya T; Mitsuhashi T; Matsumoto T; Inadama N; Nishikido F; Yoshida E; Murayama H; Kawai H; Suga M; Watanabe M
    Phys Med Biol; 2011 Nov; 56(21):6793-807. PubMed ID: 21971079
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of optical transport effects on EPID dosimetry using Geant4.
    Blake SJ; Vial P; Holloway L; Greer PB; McNamara AL; Kuncic Z
    Med Phys; 2013 Apr; 40(4):041708. PubMed ID: 23556878
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical simulation of monolithic scintillator detectors using GATE/GEANT4.
    van der Laan DJJ; Schaart DR; Maas MC; Beekman FJ; Bruyndonckx P; van Eijk CWE
    Phys Med Biol; 2010 Mar; 55(6):1659-75. PubMed ID: 20182005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Addition of luminescence process in Monte Carlo simulation to precisely estimate the light emitted from water during proton and carbon-ion irradiation.
    Yabe T; Sasano M; Hirano Y; Toshito T; Akagi T; Yamashita T; Hayashi M; Azuma T; Sakamoto Y; Komori M; Yamamoto S
    Phys Med Biol; 2018 Jun; 63(12):125019. PubMed ID: 29923503
    [TBL] [Abstract][Full Text] [Related]  

  • 20. WE-C-217BCD-11: Coupled Radiative and Optical Geant4 Simulation of MV EPIDs Based on Thick Pixelated Scintillating Crystals.
    Constantin D; Sun M; Abel E; Star-Lack J; Fahrig R
    Med Phys; 2012 Jun; 39(6Part27):3951-3952. PubMed ID: 28520011
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.