These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. Volume/perfusion ratio from lung SPECT/CT. Schaefer WM; Knollmann D; Avondo J; Meyer A Nuklearmedizin; 2018 Feb; 57(1):31-34. PubMed ID: 29536498 [TBL] [Abstract][Full Text] [Related]
25. Perfusion lung scintigraphy for the prediction of postoperative residual pulmonary function in patients with lung cancer. Kovacević-Kuśmierek K; Kozak J; Pryt Ł; Bieńkiewicz M; Cichocki P; Kuśmierek J; Płachcińska A Nucl Med Rev Cent East Eur; 2015; 18(2):70-7. PubMed ID: 26315866 [TBL] [Abstract][Full Text] [Related]
26. Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT. Cheimariotis GA; Al-Mashat M; Haris K; Aletras AH; Jögi J; Bajc M; Maglaveras N; Heiberg E Ann Nucl Med; 2018 Feb; 32(2):94-104. PubMed ID: 29236220 [TBL] [Abstract][Full Text] [Related]
27. EANM guidelines for ventilation/perfusion scintigraphy : Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography. Bajc M; Neilly JB; Miniati M; Schuemichen C; Meignan M; Jonson B; Eur J Nucl Med Mol Imaging; 2009 Aug; 36(8):1356-70. PubMed ID: 19562336 [TBL] [Abstract][Full Text] [Related]
28. The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis. Mazurek A; Dziuk M; Witkowska-Patena E; Piszczek S; Gizewska A Respiration; 2015; 90(5):393-401. PubMed ID: 26418469 [TBL] [Abstract][Full Text] [Related]
29. Validation of RAH VQ SPECT/CT lobar quantification program using a modified version of GE Q lung. Chew CG; Crouch B; Ha S; Burke A; Louise J Hell J Nucl Med; 2023; 26(1):9-19. PubMed ID: 37031418 [TBL] [Abstract][Full Text] [Related]
30. Automated quality control for segmentation of myocardial perfusion SPECT. Xu Y; Kavanagh P; Fish M; Gerlach J; Ramesh A; Lemley M; Hayes S; Berman DS; Germano G; Slomka PJ J Nucl Med; 2009 Sep; 50(9):1418-26. PubMed ID: 19690019 [TBL] [Abstract][Full Text] [Related]
31. Prediction of the postoperative pulmonary function in lung cancer patients with borderline function using ventilation-perfusion scintigraphy. Zhu X; Zhao M; Liu C; Zhou J Nucl Med Commun; 2012 Mar; 33(3):283-7. PubMed ID: 22157729 [TBL] [Abstract][Full Text] [Related]
32. [A comparison of ventilation/perfusion single photon emission CT and CT pulmonary angiography for diagnosis of pulmonary embolism]. Meng JJ; Zhang LJ; Wang Q; Fang W; Dai HJ; Yan J; Wang T; Yao ZM; He J; Li M; Mi HZ; Jiao J; Zheng YM Zhonghua Jie He He Hu Xi Za Zhi; 2013 Mar; 36(3):177-81. PubMed ID: 23856139 [TBL] [Abstract][Full Text] [Related]
33. Pulmonary functional imaging: qualitative comparison of Fourier decomposition MR imaging with SPECT/CT in porcine lung. Bauman G; Lützen U; Ullrich M; Gaass T; Dinkel J; Elke G; Meybohm P; Frerichs I; Hoffmann B; Borggrefe J; Knuth HC; Schupp J; Prüm H; Eichinger M; Puderbach M; Biederer J; Hintze C Radiology; 2011 Aug; 260(2):551-9. PubMed ID: 21586678 [TBL] [Abstract][Full Text] [Related]
34. Usefulness of lung perfusion scintigraphy before lung cancer resection in patients with ventilatory obstruction. Mineo TC; Schillaci O; Pompeo E; Mineo D; Simonetti G Ann Thorac Surg; 2006 Nov; 82(5):1828-34. PubMed ID: 17062256 [TBL] [Abstract][Full Text] [Related]
35. SPECT imaging in the diagnosis of pulmonary embolism: automated detection of match and mismatch defects by means of image-processing techniques. Reinartz P; Kaiser HJ; Wildberger JE; Gordji C; Nowak B; Buell U J Nucl Med; 2006 Jun; 47(6):968-73. PubMed ID: 16741306 [TBL] [Abstract][Full Text] [Related]
36. Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images. Ue H; Haneishi H; Iwanaga H; Suga K Ann Nucl Med; 2007 Jun; 21(3):175-83. PubMed ID: 17561589 [TBL] [Abstract][Full Text] [Related]
37. Prediction of pulmonary function after resection of primary lung cancer. Utility of inhalation-perfusion SPECT imaging. Imaeda T; Kanematsu M; Asada S; Seki M; Matsui E; Doi H; Sakai S; Kokubo M; Hirose H Clin Nucl Med; 1995 Sep; 20(9):792-9. PubMed ID: 8521655 [TBL] [Abstract][Full Text] [Related]
38. Measurement of preoperative lobar lung function with computed tomography ventilation imaging: progress towards rapid stratification of lung cancer lobectomy patients with abnormal lung function. Eslick EM; Bailey DL; Harris B; Kipritidis J; Stevens M; Li BT; Bailey E; Gradinscak D; Pollock S; Htun C; Turner R; Eade T; Aslani A; Snowdon G; Keall PJ Eur J Cardiothorac Surg; 2016 Apr; 49(4):1075-82. PubMed ID: 26248634 [TBL] [Abstract][Full Text] [Related]
39. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT. Suga K; Yasuhiko K; Iwanaga H; Tokuda O; Matsunaga N Acta Radiol; 2009 Jan; 50(1):34-41. PubMed ID: 19052938 [TBL] [Abstract][Full Text] [Related]