1. Variations in the functional visual field for detection of lung nodules on chest computed tomography: Impact of nodule size, distance, and local lung complexity. Ebner L; Tall M; Choudhury KR; Ly DL; Roos JE; Napel S; Rubin GD Med Phys; 2017 Jul; 44(7):3483-3490. PubMed ID: 28419484 [TBL] [Abstract][Full Text] [Related]
2. Computer-aided detection (CAD) in lung cancer screening at chest MDCT: ROC analysis of CAD versus radiologist performance. Fraioli F; Bertoletti L; Napoli A; Pediconi F; Calabrese FA; Masciangelo R; Catalano C; Passariello R J Thorac Imaging; 2007 Aug; 22(3):241-6. PubMed ID: 17721333 [TBL] [Abstract][Full Text] [Related]
3. Characterizing search, recognition, and decision in the detection of lung nodules on CT scans: elucidation with eye tracking. Rubin GD; Roos JE; Tall M; Harrawood B; Bag S; Ly DL; Seaman DM; Hurwitz LM; Napel S; Roy Choudhury K Radiology; 2015 Jan; 274(1):276-86. PubMed ID: 25325324 [TBL] [Abstract][Full Text] [Related]
4. Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13mSv. Messerli M; Kluckert T; Knitel M; Rengier F; Warschkow R; Alkadhi H; Leschka S; Wildermuth S; Bauer RW Eur J Radiol; 2016 Dec; 85(12):2217-2224. PubMed ID: 27842670 [TBL] [Abstract][Full Text] [Related]
5. Minimum perceivable size difference: how well can radiologists visually detect a change in lung nodule size from CT images? Solomon J; Ebner L; Christe A; Peters A; Munz J; Löbelenz L; Klaus J; Richards T; Samei E; Roos JE Eur Radiol; 2021 Apr; 31(4):1947-1955. PubMed ID: 32997175 [TBL] [Abstract][Full Text] [Related]
7. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT. Godoy MC; Kim TJ; White CS; Bogoni L; de Groot P; Florin C; Obuchowski N; Babb JS; Salganicoff M; Naidich DP; Anand V; Park S; Vlahos I; Ko JP AJR Am J Roentgenol; 2013 Jan; 200(1):74-83. PubMed ID: 23255744 [TBL] [Abstract][Full Text] [Related]
8. Improved visualization of artificial pulmonary nodules with a new subvolume rendering technique. Abildgaard A; Karlsen JS; Heiberg L; Bosse G; Hol PK Acta Radiol; 2008 Sep; 49(7):761-8. PubMed ID: 19143062 [TBL] [Abstract][Full Text] [Related]
9. Sub-solid Nodule Detection Performance on Reduced-dose Computed Tomography with Iterative Reduction: Comparison Between 20 mA (7 mAs) and 120 mA (42 mAs) Regarding Nodular Size and Characteristics and Association with Size-specific Dose Estimate. Nagatani Y; Takahashi M; Ikeda M; Yamashiro T; Koyama H; Koyama M; Moriya H; Noma S; Tomiyama N; Ohno Y; Murata K; Murayama S; Acad Radiol; 2017 Aug; 24(8):995-1007. PubMed ID: 28606593 [TBL] [Abstract][Full Text] [Related]
10. Lung nodule and cancer detection in computed tomography screening. Rubin GD J Thorac Imaging; 2015 Mar; 30(2):130-8. PubMed ID: 25658477 [TBL] [Abstract][Full Text] [Related]
11. Influence of nodule detection software on radiologists' confidence in identifying pulmonary nodules with computed tomography. Nietert PJ; Ravenel JG; Taylor KK; Silvestri GA J Thorac Imaging; 2011 Feb; 26(1):48-53. PubMed ID: 20498624 [TBL] [Abstract][Full Text] [Related]
12. Lung nodule CAD software as a second reader: a multicenter study. White CS; Pugatch R; Koonce T; Rust SW; Dharaiya E Acad Radiol; 2008 Mar; 15(3):326-33. PubMed ID: 18280930 [TBL] [Abstract][Full Text] [Related]
13. CT screening and follow-up of lung nodules: effects of tube current-time setting and nodule size and density on detectability and of tube current-time setting on apparent size. Christe A; Torrente JC; Lin M; Yen A; Hallett R; Roychoudhury K; Schmitzberger F; Vock P; Roos J AJR Am J Roentgenol; 2011 Sep; 197(3):623-30. PubMed ID: 21862804 [TBL] [Abstract][Full Text] [Related]
14. Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology. Petrou M; Quint LE; Nan B; Baker LH AJR Am J Roentgenol; 2007 Feb; 188(2):306-12. PubMed ID: 17242235 [TBL] [Abstract][Full Text] [Related]
15. Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners. Goodsitt MM; Chan HP; Way TW; Larson SC; Christodoulou EG; Kim J Med Phys; 2006 Aug; 33(8):3006-17. PubMed ID: 16964879 [TBL] [Abstract][Full Text] [Related]
16. Impact of image quality, radiologists, lung segments, and Gunnar eyewear on detectability of lung nodules in chest CT. Christe A; Ebner L; Steiger P; Parikh SR; Shah AD; Roychoudhury K; Vock P; Roos JE Acta Radiol; 2013 Jul; 54(6):646-51. PubMed ID: 23612429 [TBL] [Abstract][Full Text] [Related]
17. Improved efficiency of CT interpretation using an automated lung nodule matching program. Koo CW; Anand V; Girvin F; Wickstrom ML; Fantauzzi JP; Bogoni L; Babb JS; Ko JP AJR Am J Roentgenol; 2012 Jul; 199(1):91-5. PubMed ID: 22733898 [TBL] [Abstract][Full Text] [Related]
18. A simplified cluster model and a tool adapted for collaborative labeling of lung cancer CT scans. Morozov SP; Gombolevskiy VA; Elizarov AB; Gusev MA; Novik VP; Prokudaylo SB; Bardin AS; Popov EV; Ledikhova NV; Chernina VY; Blokhin IA; Nikolaev AE; Reshetnikov RV; Vladzymyrskyy AV; Kulberg NS Comput Methods Programs Biomed; 2021 Jul; 206():106111. PubMed ID: 33957377 [TBL] [Abstract][Full Text] [Related]
19. JOURNAL CLUB: Computer-Aided Detection of Lung Nodules on CT With a Computerized Pulmonary Vessel Suppressed Function. Lo SB; Freedman MT; Gillis LB; White CS; Mun SK AJR Am J Roentgenol; 2018 Mar; 210(3):480-488. PubMed ID: 29336601 [TBL] [Abstract][Full Text] [Related]
20. Computer-aided detection of solid lung nodules on follow-up MDCT screening: evaluation of detection, tracking, and reading time. Beigelman-Aubry C; Raffy P; Yang W; Castellino RA; Grenier PA AJR Am J Roentgenol; 2007 Oct; 189(4):948-55. PubMed ID: 17885070 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]