343 related articles for article (PubMed ID: 28422397)
1. A novel radiation protection device based on tungsten functional paper for application in interventional radiology.
Monzen H; Tamura M; Shimomura K; Onishi Y; Nakayama S; Fujimoto T; Matsumoto K; Hanaoka K; Kamomae T
J Appl Clin Med Phys; 2017 May; 18(3):215-220. PubMed ID: 28422397
[TBL] [Abstract][Full Text] [Related]
2. Reduction of Occupational Exposure Using a Novel Tungsten-Containing Rubber Shield in Interventional Radiology.
Kijima K; Krisanachinda A; Tamura M; Monzen H; Nishimura Y
Health Phys; 2020 Jun; 118(6):609-614. PubMed ID: 31855596
[TBL] [Abstract][Full Text] [Related]
3. Reduction of Operator Hand Exposure in Interventional Radiology With a Novel Finger Sack Using Tungsten-containing Rubber.
Kosaka H; Monzen H; Matsumoto K; Tamura M; Nishimura Y
Health Phys; 2019 May; 116(5):625-630. PubMed ID: 30688684
[TBL] [Abstract][Full Text] [Related]
4. CT fluoroscopy shielding: decreases in scattered radiation for the patient and operator.
Neeman Z; Dromi SA; Sarin S; Wood BJ
J Vasc Interv Radiol; 2006 Dec; 17(12):1999-2004. PubMed ID: 17185699
[TBL] [Abstract][Full Text] [Related]
5. Estimation of the shielding ability of a tungsten functional paper for diagnostic x-rays and gamma rays.
Monzen H; Kanno I; Fujimoto T; Hiraoka M
J Appl Clin Med Phys; 2017 Sep; 18(5):325-329. PubMed ID: 28656739
[TBL] [Abstract][Full Text] [Related]
6. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty.
Smith JR; Marsh RM; Silosky MS
Skeletal Radiol; 2018 Jan; 47(1):37-43. PubMed ID: 28821928
[TBL] [Abstract][Full Text] [Related]
7. Comparing strategies for operator eye protection in the interventional radiology suite.
Thornton RH; Dauer LT; Altamirano JP; Alvarado KJ; St Germain J; Solomon SB
J Vasc Interv Radiol; 2010 Nov; 21(11):1703-7. PubMed ID: 20920841
[TBL] [Abstract][Full Text] [Related]
8. Radioprotective Effects of a Semicircular X-ray Shielding Device for Operators During CT Fluoroscopy-Guided Interventional Procedures: Experimental and Clinical Studies.
Kikuchi K; Takaki H; Matsumoto K; Kobayashi K; Kako Y; Kodama H; Ogasawara A; Taniguchi J; Takahagi M; Hagihara Y; Yamakado K
Cardiovasc Intervent Radiol; 2023 Jun; 46(6):770-776. PubMed ID: 37188896
[TBL] [Abstract][Full Text] [Related]
9. Reduction of operator radiation dose by an extended lower body shield.
Gonzales JP; Moran C; Silberzweig JE
J Vasc Interv Radiol; 2014 Mar; 25(3):462-8, 468.e1. PubMed ID: 24332242
[TBL] [Abstract][Full Text] [Related]
10. Estimating radiation exposure of the brain of a physician with a protective flap in interventional radiology: A phantom study.
Hattori S; Monzen H; Tamura M; Kosaka H; Nakamura Y; Nishimura Y
J Appl Clin Med Phys; 2022 Mar; 23(3):e13532. PubMed ID: 35045212
[TBL] [Abstract][Full Text] [Related]
11. Usefulness of an additional lead shielding device in reducing occupational radiation exposure during interventional endoscopic procedures: An observational study.
Yamada R; Saimyo Y; Tanaka K; Hattori A; Umeda Y; Kuroda N; Tsuboi J; Hamada Y; Takei Y
Medicine (Baltimore); 2020 Aug; 99(34):e21831. PubMed ID: 32846829
[TBL] [Abstract][Full Text] [Related]
12. Effectiveness of a new radiation protection system in the interventional radiology setting.
Etzel R; König AM; Keil B; Fiebich M; Mahnken AH
Eur J Radiol; 2018 Sep; 106():56-61. PubMed ID: 30150051
[TBL] [Abstract][Full Text] [Related]
13. Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom.
Morishima Y; Chida K; Muroya Y; Utsumi Y
Dysphagia; 2018 Feb; 33(1):109-114. PubMed ID: 28921404
[TBL] [Abstract][Full Text] [Related]
14. Optimizing Staff Dose in Fluoroscopy-Guided Interventions by Comparing Clinical Data with Phantom Experiments.
Sailer AM; Paulis L; Vergoossen L; Wildberger JE; Jeukens CRLPN
J Vasc Interv Radiol; 2019 May; 30(5):701-708.e1. PubMed ID: 30952523
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric shield evaluation with tungsten sheet in 4, 6, and 9MeV electron beams.
Fujimoto T; Monzen H; Nakata M; Okada T; Yano S; Takakura T; Kuwahara J; Sasaki M; Higashimura K; Hiraoka M
Phys Med; 2014 Nov; 30(7):838-42. PubMed ID: 24953537
[TBL] [Abstract][Full Text] [Related]
16. Comparison of radiation dose to operator between transradial and transfemoral coronary angiography with optimised radiation protection: a phantom study.
Liu H; Jin Z; Jing L
Radiat Prot Dosimetry; 2014 Mar; 158(4):412-20. PubMed ID: 24162374
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures.
Ferrari P; Becker F; Carinou E; Chumak V; Farah J; Jovanovic Z; Krstic D; Morgun A; Principi S; Teles P
J Radiol Prot; 2016 Dec; 36(4):902-921. PubMed ID: 27861170
[TBL] [Abstract][Full Text] [Related]
18. [The radiation protective devices for interventional procedures using computed tomography].
Iida H; Chabatake M; Shimizu M; Tamura S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2002 Jan; 58(1):101-8. PubMed ID: 12527880
[TBL] [Abstract][Full Text] [Related]
19. Radiation Protection for the Fluoroscopy Operator and Staff.
Meisinger QC; Stahl CM; Andre MP; Kinney TB; Newton IG
AJR Am J Roentgenol; 2016 Oct; 207(4):745-754. PubMed ID: 27440524
[TBL] [Abstract][Full Text] [Related]
20. The addition of a leaded arm sleeve to leaded aprons further decreases operator upper outer quadrant chest wall radiation dose during fluoroscopically guided interventions.
Ramanan B; Pizano A; Solano A; Gonugunta AS; Timaran CH; Siah M; Baig S; Shih M; Guild JB; Kirkwood ML
J Vasc Surg; 2024 Apr; 79(4):948-953. PubMed ID: 38040201
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]