These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 2842343)

  • 1. Mineralization and calcium fixation within a porous apatitic ceramic material after implantation in the femur of rabbits.
    Krajewski A; Ravaglioli A; Mongiorgi R; Moroni A
    J Biomed Mater Res; 1988 Jun; 22(6):445-57. PubMed ID: 2842343
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Porous hydroxyapatite and tricalcium phosphate cylinders with two different pore size ranges implanted in the cancellous bone of rabbits. A comparative histomorphometric and histologic study of bony ingrowth and implant substitution.
    Eggli PS; Müller W; Schenk RK
    Clin Orthop Relat Res; 1988 Jul; (232):127-38. PubMed ID: 2838207
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [The interface between hydroxyapatite ceramic and newly formed bone in scanning electron microscopy].
    Brill W; Katthagen BD
    Z Orthop Ihre Grenzgeb; 1987; 125(2):183-7. PubMed ID: 3039750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Formation of carbonate-apatite crystals after implantation of calcium phosphate ceramics.
    Daculsi G; LeGeros RZ; Heughebaert M; Barbieux I
    Calcif Tissue Int; 1990 Jan; 46(1):20-7. PubMed ID: 2153039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biodegradation behavior of various calcium phosphate materials in bone tissue.
    Klein CP; Driessen AA; de Groot K; van den Hooff A
    J Biomed Mater Res; 1983 Sep; 17(5):769-84. PubMed ID: 6311838
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biocompatibility of zirconia dispersed hydroxyapatite ceramics.
    Suzuki O; Suda A; Sato T; Takagi M; Osanai T
    Nihon Seikeigeka Gakkai Zasshi; 1990 Apr; 64(4):249-59. PubMed ID: 2166117
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physicochemical characterization of deposits associated with HA ceramics implanted in nonosseous sites.
    Heughebaert M; LeGeros RZ; Gineste M; Guilhem A; Bonel G
    J Biomed Mater Res; 1988 Dec; 22(3 Suppl):257-68. PubMed ID: 3235463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Macroporous calcium phosphate ceramic for long bone surgery in humans and dogs. Clinical and histological study.
    Daculsi G; Passuti N; Martin S; Deudon C; Legeros RZ; Raher S
    J Biomed Mater Res; 1990 Mar; 24(3):379-96. PubMed ID: 2318901
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A mechanical investigation of fluorapatite, magnesiumwhitlockite, and hydroxylapatite plasma-sprayed coatings in goats.
    Dhert WJ; Klein CP; Wolke JG; van der Velde EA; de Groot K; Rozing PM
    J Biomed Mater Res; 1991 Oct; 25(10):1183-200. PubMed ID: 1667400
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The evaluation of a biphasic calcium phosphate ceramic for use in grafting long-bone diaphyseal defects.
    Moore DC; Chapman MW; Manske D
    J Orthop Res; 1987; 5(3):356-65. PubMed ID: 3040949
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The use of ceramics for bone replacement. A comparative study of three different porous ceramics.
    Uchida A; Nade SM; McCartney ER; Ching W
    J Bone Joint Surg Br; 1984 Mar; 66(2):269-75. PubMed ID: 6323483
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tensile strength of the interface between hydroxyapatite and bone.
    Hong L; Xu HC; de Groot K
    J Biomed Mater Res; 1992 Jan; 26(1):7-18. PubMed ID: 1315777
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bone ingrowth into porous calcium phosphate ceramics: influence of pulsing electromagnetic field.
    Shimizu T; Zerwekh JE; Videman T; Gill K; Mooney V; Holmes RE; Hagler HK
    J Orthop Res; 1988; 6(2):248-58. PubMed ID: 2830390
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The interface of calcium-phosphate and glass-ceramic in bone, a structural analysis.
    Gross UM; Müller-Mai CM; Voigt C
    Biomaterials; 1990 Jul; 11():83-5. PubMed ID: 2397266
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Scanning electron microscopy-electron probe microanalysis study of the interface between apatite and wollastonite-containing glass-ceramic and rabbit tibia under load-bearing conditions after long-term implantation.
    Kitsugi T; Yamamuro T; Nakamura T; Oka M; Kokubo T; Okunaga K; Shibuya T
    Calcif Tissue Int; 1995 Apr; 56(4):331-5. PubMed ID: 7767846
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Behaviour of titanium and titania-based ceramics in vitro and in vivo.
    Li J
    Biomaterials; 1993 Feb; 14(3):229-32. PubMed ID: 8386556
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reaction of bone to HA, carbonate-HA, hydroxyapatite + calcium orthophosphate and to hydroxyapatite + calcium ortho- and pyrophosphate.
    Nordström EG; Niemi L; Miettinen J
    Biomed Mater Eng; 1992; 2(3):115-21. PubMed ID: 1333868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new glass-ceramic for bone replacement: evaluation of its bonding to bone tissue.
    Nakamura T; Yamamuro T; Higashi S; Kokubo T; Itoo S
    J Biomed Mater Res; 1985; 19(6):685-98. PubMed ID: 3001094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bone ingrowth into three different porous ceramics implanted into the tibia of rats and rabbits.
    Uchida A; Nade S; McCartney E; Ching W
    J Orthop Res; 1985; 3(1):65-77. PubMed ID: 2984392
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.