BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1458 related articles for article (PubMed ID: 28427598)

  • 1. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
    Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
    JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of Annular Oversizing on Paravalvular Regurgitation and Valve Hemodynamics: New Insights From PARTNER 3.
    Ihdayhid AR; Leipsic J; Hahn RT; Pibarot P; Thourani V; Makkar R; Kodali S; Russo M; Kapadia S; Chen Y; Mack M; Webb J; Bax J; Leon MB; Blanke P
    JACC Cardiovasc Interv; 2021 Oct; 14(19):2158-2169. PubMed ID: 34620395
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation.
    Hansson NC; Leipsic J; Pugliese F; Andersen HR; Rossi A; Simonato M; Jensen KT; Christiansen EH; Terkelsen CJ; Blanke P; Tang M; Krusell LR; Klaaborg KE; Terp K; Kennon S; Dvir D; Bøtker HE; Webb J; Nørgaard BL
    J Cardiovasc Comput Tomogr; 2018; 12(4):290-297. PubMed ID: 29519754
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
    Popma JJ; Gleason TG; Yakubov SJ; Harrison JK; Forrest JK; Maini B; Ruiz CE; Pinto DS; Costa M; Resar J; Conte J; Crestanello J; Chang Y; Oh JK; Reardon MJ; Adams DH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27369803
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry.
    Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.
    Willson AB; Webb JG; Labounty TM; Achenbach S; Moss R; Wheeler M; Thompson C; Min JK; Gurvitch R; Norgaard BL; Hague CJ; Toggweiler S; Binder R; Freeman M; Poulter R; Poulsen S; Wood DA; Leipsic J
    J Am Coll Cardiol; 2012 Apr; 59(14):1287-94. PubMed ID: 22365423
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictive value for paravalvular regurgitation of 3-dimensional anatomic aortic annulus shape assessed by multidetector computed tomography post-transcatheter aortic valve replacement.
    Ciobotaru V; Maupas E; Dürrleman N; Boulenc JM; Borton A; Pujadas-Berthault P; Rioux P; Maubon A
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):85-95. PubMed ID: 26003147
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial.
    Binder RK; Webb JG; Willson AB; Urena M; Hansson NC; Norgaard BL; Pibarot P; Barbanti M; Larose E; Freeman M; Dumont E; Thompson C; Wheeler M; Moss RR; Yang TH; Pasian S; Hague CJ; Nguyen G; Raju R; Toggweiler S; Min JK; Wood DA; Rodés-Cabau J; Leipsic J
    J Am Coll Cardiol; 2013 Jul; 62(5):431-8. PubMed ID: 23684679
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation.
    Binder RK; Webb JG; Toggweiler S; Freeman M; Barbanti M; Willson AB; Alhassan D; Hague CJ; Wood DA; Leipsic J
    JACC Cardiovasc Interv; 2013 May; 6(5):462-8. PubMed ID: 23702010
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computed tomography-based oversizing and incidence of paravalvular aortic regurgitation and permanent pacemaker implantation with a new-generation self-expanding transcatheter heart valve.
    Kim U; Blanke P; Windecker S; Kasel AM; Schäfer U; Walters D; Linke A; Le Breton H; Schymik G; Spence MS; Søndergaard L; Abdel-Wahab M; Worthley S; Tchétché D; Reichenspurner H; Ohana M; Sellers SL; Leipsic JA
    EuroIntervention; 2018 Aug; 14(5):e511-e518. PubMed ID: 29741486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve.
    Binder RK; Rodés-Cabau J; Wood DA; Mok M; Leipsic J; De Larochellière R; Toggweiler S; Dumont E; Freeman M; Willson AB; Webb JG
    JACC Cardiovasc Interv; 2013 Mar; 6(3):293-300. PubMed ID: 23517842
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.
    Kaneko H; Hoelschermann F; Tambor G; Yoon SH; Neuss M; Butter C
    Am J Cardiol; 2017 Feb; 119(4):618-622. PubMed ID: 28010874
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multicenter evaluation of transcatheter aortic valve replacement using either SAPIEN XT or CoreValve: Degree of device oversizing by computed-tomography and clinical outcomes.
    Dvir D; Webb JG; Piazza N; Blanke P; Barbanti M; Bleiziffer S; Wood DA; Mylotte D; Wilson AB; Tan J; Stub D; Tamburino C; Lange R; Leipsic J
    Catheter Cardiovasc Interv; 2015 Sep; 86(3):508-15. PubMed ID: 25573784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of CoreValve size selection based on multi-slice computed tomography on paravalvular leak after transcatheter aortic valve implantation.
    Chodór P; Wilczek K; Przybylski R; Głowacki J; Kukulski T; Streb W; Niklewski T; Honisz G; Trzeciak P; Podolecki T; Włoch Ł; Zembala M; Kalarus Z
    Cardiol J; 2017; 24(5):467-476. PubMed ID: 28150295
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes.
    Tan JS; Leipsic J; Perlman G; Stub D; Dvir D; Hansson NC; Norgaard BL; Blanke P; Cheung A; Ye J; Thompson CR; Moss RR; Lauck S; Wood D; Webb J
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1727-32. PubMed ID: 26476612
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial.
    Willson AB; Webb JG; Freeman M; Wood DA; Gurvitch R; Thompson CR; Moss RR; Toggweiler S; Binder RK; Munt B; Cheung A; Hague C; Ye J; Leipsic JA
    J Cardiovasc Comput Tomogr; 2012; 6(6):406-14. PubMed ID: 23127390
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 73.