These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 28433059)

  • 21. A signal-on fluorescence based biosensing platform for highly sensitive detection of DNA methyltransferase enzyme activity and inhibition.
    Dadmehr M; Karimi MA; Korouzhdehi B
    Spectrochim Acta A Mol Biomol Spectrosc; 2020 Mar; 228():117731. PubMed ID: 31753656
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A microchip electrophoretic assay for DNA methyltransferase activity based on methylation-sensitive endonuclease DpnⅡ.
    Zhang Y; Zhang Y; Zhu L; He P; Wang Q
    Electrophoresis; 2019 Feb; 40(3):425-430. PubMed ID: 30033657
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Detection of DNA methyltransferase activity using template-free DNA polymerization amplification based on aggregation-induced emission.
    Niu S; Bi C; Song W
    Anal Biochem; 2020 Feb; 590():113532. PubMed ID: 31821806
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Highly efficient electrochemical sensing platform for sensitive detection DNA methylation, and methyltransferase activity based on Ag NPs decorated carbon nanocubes.
    Gao F; Fan T; Ou S; Wu J; Zhang X; Luo J; Li N; Yao Y; Mou Y; Liao X; Geng D
    Biosens Bioelectron; 2018 Jan; 99():201-208. PubMed ID: 28759870
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Plasmonic Au nanocube enhanced SERS biosensor based on heated electrode and strand displacement amplification for highly sensitive detection of Dam methyltransferase activity.
    Hu HC; Wu SH; Jin LX; Sun JJ
    Biosens Bioelectron; 2022 Aug; 210():114283. PubMed ID: 35447396
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Self-Powered Biosensing Platform Based on "Signal-On" Enzymatic Biofuel Cell for DNA Methyltransferase Activity Analysis and Inhibitor Screening.
    Gu C; Gai P; Kong X; Hou T; Li F
    Anal Chem; 2020 Apr; 92(7):5426-5430. PubMed ID: 32133847
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Construction of an APE1-Mediated Cascade Signal Amplification Platform for Homogeneously Sensitive and Rapid Measurement of DNA Methyltransferase in
    Han Y; Wang C; Zou X; Zhang Y; Xu Q; Zhang CY
    Anal Chem; 2022 Apr; 94(15):5980-5986. PubMed ID: 35394287
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sensitive SERS detection of DNA methyltransferase by target triggering primer generation-based multiple signal amplification strategy.
    Li Y; Yu C; Han H; Zhao C; Zhang X
    Biosens Bioelectron; 2016 Jul; 81():111-116. PubMed ID: 26926592
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An electrochemical assay for DNA methylation, methyltransferase activity and inhibitor screening based on methyl binding domain protein.
    Yin H; Zhou Y; Xu Z; Chen L; Zhang D; Ai S
    Biosens Bioelectron; 2013 Mar; 41():492-7. PubMed ID: 23021851
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Chemiluminescence resonance energy transfer biosensing platform for site-specific determination of DNA methylation and assay of DNA methyltransferase activity using exonuclease III-assisted target recycling amplification.
    Chen C; Li B
    Biosens Bioelectron; 2014 Apr; 54():48-54. PubMed ID: 24240168
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Label-free and immobilization-free photoelectrochemical biosensing strategy using methylene blue in homogeneous solution as signal probe for facile DNA methyltransferase activity assay.
    Hou T; Xu N; Wang W; Ge L; Li F
    Biosens Bioelectron; 2019 Sep; 141():111395. PubMed ID: 31195203
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Highly sensitive detection of DNA methyltransferase activity and its inhibitor screening by coupling fluorescence correlation spectroscopy with polystyrene polymer dots.
    Huang Y; Deng L; Su D; Huang X; Ren J
    Analyst; 2021 Jun; 146(11):3623-3632. PubMed ID: 33929479
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Magnetic nanoparticles-cooperated fluorescence sensor for sensitive and accurate detection of DNA methyltransferase activity coupled with exonuclease III-assisted target recycling.
    Xue Q; Zhang Y; Xu S; Li H; Wang L; Li R; Zhang Y; Yue Q; Gu X; Zhang S; Liu J; Wang H
    Analyst; 2015 Nov; 140(22):7637-44. PubMed ID: 26421322
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A sensitive strategy for the fluorescence detection of DNA methyltransferase activity based on the graphene oxide platform and T7 exonuclease-assisted cyclic signal amplification.
    Ma Y; Chen L; Zhang L; Liao S; Zhao J
    Analyst; 2015 Jun; 140(12):4076-82. PubMed ID: 25882858
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Quencher-free fluorescence strategy for detection of DNA methyltransferase activity based on exonuclease III-assisted signal amplification.
    Liu H; Ma C; Zhou M; Chen H; He H; Wang K
    Anal Bioanal Chem; 2016 Nov; 408(28):8111-8116. PubMed ID: 27628090
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multiple sealed primers-mediated rolling circle amplification strategy for sensitive and specific detection of DNA methyltransferase activity.
    Xu X; Wang L; Li X; Cui W; Jiang W
    Talanta; 2019 Mar; 194():282-288. PubMed ID: 30609532
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Carbon nanotube signal amplification for ultrasensitive fluorescence polarization detection of DNA methyltransferase activity and inhibition.
    Huang Y; Shi M; Zhao L; Zhao S; Hu K; Chen ZF; Chen J; Liang H
    Biosens Bioelectron; 2014 Apr; 54():285-91. PubMed ID: 24287418
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Magnetic bead-liposome hybrids enable sensitive and portable detection of DNA methyltransferase activity using personal glucose meter.
    Zhang Y; Xue Q; Liu J; Wang H
    Biosens Bioelectron; 2017 Jan; 87():537-544. PubMed ID: 27611472
    [TBL] [Abstract][Full Text] [Related]  

  • 39. DNA-AuNPs based signal amplification for highly sensitive detection of DNA methylation, methyltransferase activity and inhibitor screening.
    Jing X; Cao X; Wang L; Lan T; Li Y; Xie G
    Biosens Bioelectron; 2014 Aug; 58():40-7. PubMed ID: 24613968
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ultrasensitive homogeneous electrochemical strategy for DNA methyltransferase activity assay based on autonomous exonuclease III-assisted isothermal cycling signal amplification.
    Li W; Liu X; Hou T; Li H; Li F
    Biosens Bioelectron; 2015 Aug; 70():304-9. PubMed ID: 25840015
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.