BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

318 related articles for article (PubMed ID: 28439886)

  • 1. Lifebox pulse oximeter implementation in Malawi: evaluation of educational outcomes and impact on oxygen desaturation episodes during anaesthesia.
    Albert V; Mndolo S; Harrison EM; O'Sullivan E; Wilson IH; Walker IA
    Anaesthesia; 2017 Jun; 72(6):686-693. PubMed ID: 28439886
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a large-scale donation of Lifebox pulse oximeters to non-physician anaesthetists in Uganda.
    Finch LC; Kim RY; Ttendo S; Kiwanuka JK; Walker IA; Wilson IH; Weiser TG; Berry WR; Gawande AA
    Anaesthesia; 2014 May; 69(5):445-51. PubMed ID: 24738801
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The response times during anaesthesia of pulse oximeters measuring oxygen saturations during hypoxaemic events.
    Broome IJ; Harris RW; Reilly CS
    Anaesthesia; 1992 Jan; 47(1):17-9. PubMed ID: 1536395
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Global oximetry: an international anaesthesia quality improvement project.
    Walker IA; Merry AF; Wilson IH; McHugh GA; O'Sullivan E; Thoms GM; Nuevo F; Whitaker DK;
    Anaesthesia; 2009 Oct; 64(10):1051-60. PubMed ID: 19735394
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Oxygen Reserve Index: Utility as an Early Warning for Desaturation in High-Risk Surgical Patients.
    Fleming NW; Singh A; Lee L; Applegate RL
    Anesth Analg; 2021 Mar; 132(3):770-776. PubMed ID: 32815872
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The impact of pulse oximetry and Integrated Management of Childhood Illness (IMCI) training on antibiotic prescribing practices in rural Malawi: A mixed-methods study.
    Sylvies F; Nyirenda L; Blair A; Baltzell K
    PLoS One; 2020; 15(11):e0242440. PubMed ID: 33211744
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incidence of hypoxia and related events detected by pulse oximeters provided by the Lifebox Foundation in the maternity unit at Sylvanus Olympio University Teaching Hospital, Togo.
    Sama HD; Maman AF; Walker IA
    J Anesth; 2015 Dec; 29(6):971-3. PubMed ID: 26198600
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Anesthesia related hypoxemia. The effect of pulse oximetry monitoring on perioperative events and postoperative complications.
    Møller JT
    Dan Med Bull; 1994 Nov; 41(5):489-500. PubMed ID: 7859517
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.
    Pertzov B; Brachfeld E; Unterman A; Gershman E; Abdel-Rahman N; Rosengarten D; Kramer MR
    Lung; 2019 Feb; 197(1):67-72. PubMed ID: 30474708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incidence of intraoperative hypoxemia in children in relation to age.
    de Graaff JC; Bijker JB; Kappen TH; van Wolfswinkel L; Zuithoff NP; Kalkman CJ
    Anesth Analg; 2013 Jul; 117(1):169-75. PubMed ID: 23687233
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulse oximetry monitoring outside the intensive care unit: progress or problem?
    Bowton DL; Scuderi PE; Harris L; Haponik EF
    Ann Intern Med; 1991 Sep; 115(6):450-4. PubMed ID: 1872492
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effective introduction of Lifebox pulse oximetry to Malawi.
    Scott DA; McDougall R
    Anaesthesia; 2017 Jun; 72(6):675-677. PubMed ID: 28439874
    [No Abstract]   [Full Text] [Related]  

  • 13. Critical incidents detected by pulse oximetry during anaesthesia.
    McKay WP; Noble WH
    Can J Anaesth; 1988 May; 35(3 ( Pt 1)):265-9. PubMed ID: 3383318
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters.
    Choi SJ; Ahn HJ; Yang MK; Kim CS; Sim WS; Kim JA; Kang JG; Kim JK; Kang JY
    Acta Anaesthesiol Scand; 2010 Feb; 54(2):212-7. PubMed ID: 19719816
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Opportunities and barriers in paediatric pulse oximetry for pneumonia in low-resource clinical settings: a qualitative evaluation from Malawi and Bangladesh.
    King C; Boyd N; Walker I; Zadutsa B; Baqui AH; Ahmed S; Islam M; Kainja E; Nambiar B; Wilson I; McCollum ED
    BMJ Open; 2018 Jan; 8(1):e019177. PubMed ID: 29382679
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Predictive value of pulse oximetry for mortality in infants and children presenting to primary care with clinical pneumonia in rural Malawi: A data linkage study.
    Colbourn T; King C; Beard J; Phiri T; Mdala M; Zadutsa B; Makwenda C; Costello A; Lufesi N; Mwansambo C; Nambiar B; Hooli S; French N; Bar Zeev N; Qazi SA; Bin Nisar Y; McCollum ED
    PLoS Med; 2020 Oct; 17(10):e1003300. PubMed ID: 33095763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of medical training and clinical experience on the assessment of oxygenation and hypoxaemia after general anaesthesia: an observational study.
    Aust H; Kranke P; Eberhart LH; Afshari A; Weber F; Brieskorn M; Heine J; Arndt C; Rüsch D
    J Clin Monit Comput; 2015 Jun; 29(3):415-26. PubMed ID: 25273623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers.
    Dubowitz G; Breyer K; Lipnick M; Sall JW; Feiner J; Ikeda K; MacLeod DB; Bickler PE
    Anaesthesia; 2013 Dec; 68(12):1220-3. PubMed ID: 23992483
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Variability in the use of pulse oximeters with children in Kenyan hospitals: A mixed-methods analysis.
    Enoch AJ; English M; ; McGivern G; Shepperd S
    PLoS Med; 2019 Dec; 16(12):e1002987. PubMed ID: 31891572
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.