These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
877 related articles for article (PubMed ID: 28440239)
1. Feasibility, safety, and outcomes of a single-step endoscopic ultrasonography-guided drainage of pancreatic fluid collections without fluoroscopy using a novel electrocautery-enhanced lumen-apposing, self-expanding metal stent. Yoo J; Yan L; Hasan R; Somalya S; Nieto J; Siddiqui AA Endosc Ultrasound; 2017; 6(2):131-135. PubMed ID: 28440239 [TBL] [Abstract][Full Text] [Related]
2. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos). Siddiqui AA; Adler DG; Nieto J; Shah JN; Binmoeller KF; Kane S; Yan L; Laique SN; Kowalski T; Loren DE; Taylor LJ; Munigala S; Bhat YM Gastrointest Endosc; 2016 Apr; 83(4):699-707. PubMed ID: 26515956 [TBL] [Abstract][Full Text] [Related]
3. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success. Siddiqui AA; Kowalski TE; Loren DE; Khalid A; Soomro A; Mazhar SM; Isby L; Kahaleh M; Karia K; Yoo J; Ofosu A; Ng B; Sharaiha RZ Gastrointest Endosc; 2017 Apr; 85(4):758-765. PubMed ID: 27566053 [TBL] [Abstract][Full Text] [Related]
4. Efficacy and Safety of Lumen-Apposing Metal Stents in Management of Pancreatic Fluid Collections: Are They Better Than Plastic Stents? A Systematic Review and Meta-Analysis. Hammad T; Khan MA; Alastal Y; Lee W; Nawras A; Ismail MK; Kahaleh M Dig Dis Sci; 2018 Feb; 63(2):289-301. PubMed ID: 29282638 [TBL] [Abstract][Full Text] [Related]
5. A retrospective study evaluating endoscopic ultrasound-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery enhanced delivery system. Adler DG; Taylor LJ; Hasan R; Siddiqui AA Endosc Ultrasound; 2017; 6(6):389-393. PubMed ID: 29251273 [TBL] [Abstract][Full Text] [Related]
6. Lumen-apposing-metal stent misdeployment in endoscopic ultrasound-guided drainages: A systematic review focusing on issues and rescue management. Armellini E; Metelli F; Anderloni A; Cominardi A; Aragona G; Marini M; Pace F World J Gastroenterol; 2023 Jun; 29(21):3341-3361. PubMed ID: 37377584 [TBL] [Abstract][Full Text] [Related]
7. EUS-guided drainage of pancreatic fluid collections using lumen apposing metal stents: An international, multicenter experience. Kumta NA; Tyberg A; Bhagat VH; Siddiqui AA; Kowalski TE; Loren DE; Desai AP; Sarkisian AM; Brown EG; Karia K; Gaidhane M; Kedia P; Tarnasky PR; Patel U; Adler D; Taylor LJ; Petrone M; Arcidiacono P; Yachimski PS; Weine D; Sundararajan S; Deprez PH; Mouradides C; Ho S; Javed S; Easler JJ; Raijman I; Vazquez-Sequeiros E; Sawhney M; Berzin TM; Kahaleh M Dig Liver Dis; 2019 Nov; 51(11):1557-1561. PubMed ID: 31272934 [TBL] [Abstract][Full Text] [Related]
8. Drainage of pancreatic fluid collections using a lumen-apposing metal stent with an electrocautery-enhanced delivery system. Khan S; Chandran S; Chin J; Karim S; Mangira D; Nasr M; Ermerak G; Trinh A; Kia CYH; Mules T; Zad M; Ang TL; Johns E; Tee D; Kaul A; Ratanachu-Ek T; Jirathan-Opas J; Fisher L; Cameron R; Welch C; Lim G; Metz AJ; Moss A; Bassan M; Saxena P; Kaffes A; St John A; Hourigan LF; Tagkalidis P; Weilert F; Vaughan R; Devereaux B J Gastroenterol Hepatol; 2021 Dec; 36(12):3395-3401. PubMed ID: 34370869 [TBL] [Abstract][Full Text] [Related]
9. Head-to-head comparison between endoscopic ultrasound guided lumen apposing metal stent and plastic stents for the treatment of pancreatic fluid collections: A systematic review and meta-analysis. Guzmán-Calderón E; Chacaltana A; Díaz R; Li B; Martinez-Moreno B; Aparicio JR J Hepatobiliary Pancreat Sci; 2022 Feb; 29(2):198-211. PubMed ID: 34107170 [TBL] [Abstract][Full Text] [Related]
10. Comparative outcomes of endoscopic ultrasound-guided lumen-apposing mental stents drainage for pancreatic pseudocysts and walled-off necrosis: Case series and meta-analysis. Li J; Zhang Q; Zhou A; Zhao G; Li P Chronic Dis Transl Med; 2021 Sep; 7(3):157-168. PubMed ID: 34505016 [TBL] [Abstract][Full Text] [Related]
11. A novel lumen-apposing metal stent with an anti-reflux valve for endoscopic ultrasound-guided drainage of pseudocysts and walled-off necrosis: A pilot study. Cho IR; Chung MJ; Jo JH; Lee HS; Park JY; Bang S; Park SW; Song SY PLoS One; 2019; 14(9):e0221812. PubMed ID: 31483821 [TBL] [Abstract][Full Text] [Related]
12. Multicenter study of the efficacy and safety of electrocautery-enhanced lumen-apposing metal stents for the internal drainage of pancreatic fluid collections. Chung CS; Kuo YT; Chiu YC; Lin YC; Yang CY; Chen KC; Liao SC; Sun CK; Lin YC; Wang HP Sci Rep; 2024 Mar; 14(1):5481. PubMed ID: 38443387 [TBL] [Abstract][Full Text] [Related]
13. Clinical outcomes of endoscopic management of pancreatic fluid collections in cirrhotics Laique S; Franco MC; Stevens T; Bhatt A; Vargo JJ; Chahal P World J Gastrointest Endosc; 2019 Jun; 11(6):403-412. PubMed ID: 31236193 [TBL] [Abstract][Full Text] [Related]
14. Lumen-apposing metal stents versus traditional self-expanding metal stents for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a systematic review and meta-analysis. Tian Y; Yin C; Ma Y; Fu G; Liu R; Ran H; Pan T; Xiao Y; Wen X Surg Endosc; 2024 Feb; 38(2):586-596. PubMed ID: 38151677 [TBL] [Abstract][Full Text] [Related]
15. EUS-guided transrectal drainage of pelvic fluid collections using electrocautery-enhanced lumen-apposing metal stents: a case series. Lisotti A; Cominardi A; Bacchilega I; Linguerri R; Fusaroli P VideoGIE; 2020 Aug; 5(8):380-385. PubMed ID: 32821872 [TBL] [Abstract][Full Text] [Related]
16. Safety and rate of delayed adverse events with lumen-apposing metal stents (LAMS) for pancreatic fluid collections: a multicenter study. Yang D; Perbtani YB; Mramba LK; Kerdsirichairat T; Prabhu A; Manvar A; Ho S; Pannu D; Keswani RN; Strand DS; Wang AY; Quintero E; Buscaglia JM; Muniraj T; Aslanian HR; Draganov PV; Siddiqui AS Endosc Int Open; 2018 Oct; 6(10):E1267-E1275. PubMed ID: 30302385 [No Abstract] [Full Text] [Related]
17. Endoscopic Therapy With Lumen-apposing Metal Stents Is Safe and Effective for Patients With Pancreatic Walled-off Necrosis. Sharaiha RZ; Tyberg A; Khashab MA; Kumta NA; Karia K; Nieto J; Siddiqui UD; Waxman I; Joshi V; Benias PC; Darwin P; DiMaio CJ; Mulder CJ; Friedland S; Forcione DG; Sejpal DV; Gonda TA; Gress FG; Gaidhane M; Koons A; DeFilippis EM; Salgado S; Weaver KR; Poneros JM; Sethi A; Ho S; Kumbhari V; Singh VK; Tieu AH; Parra V; Likhitsup A; Womeldorph C; Casey B; Jonnalagadda SS; Desai AP; Carr-Locke DL; Kahaleh M; Siddiqui AA Clin Gastroenterol Hepatol; 2016 Dec; 14(12):1797-1803. PubMed ID: 27189914 [TBL] [Abstract][Full Text] [Related]
18. Protocol of early lumen apposing metal stent removal for pseudocysts and walled off necrosis avoids bleeding complications. Ahmad W; Fehmi SA; Savides TJ; Anand G; Chang MA; Kwong WT Scand J Gastroenterol; 2020 Feb; 55(2):242-247. PubMed ID: 31942808 [No Abstract] [Full Text] [Related]
19. Safety and efficacy of endoscopic ultrasound-guided drainage of pancreatic fluid collections with lumen-apposing covered self-expanding metal stents. Shah RJ; Shah JN; Waxman I; Kowalski TE; Sanchez-Yague A; Nieto J; Brauer BC; Gaidhane M; Kahaleh M Clin Gastroenterol Hepatol; 2015 Apr; 13(4):747-52. PubMed ID: 25290534 [TBL] [Abstract][Full Text] [Related]
20. Comparison of Clinical Outcomes between Plastic Stent and Novel Lumen-apposing Metal Stent for Endoscopic Ultrasound-Guided Drainage of Peripancreatic Fluid Collections. Shin HC; Cho CM; Jung MK; Yeo SJ Clin Endosc; 2019 Jul; 52(4):353-359. PubMed ID: 30862153 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]