These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 28451619)

  • 1. Tape Versus Suture in Arthroscopic Rotator Cuff Repair: Biomechanical Analysis and Assessment of Failure Rates at 6 Months.
    Liu RW; Lam PH; Shepherd HM; Murrell GAC
    Orthop J Sports Med; 2017 Apr; 5(4):2325967117701212. PubMed ID: 28451619
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of Suture Tapes Versus Conventional Sutures for Arthroscopic Rotator Cuff Repairs: A Systematic Review and Meta-analysis.
    Boksh K; Haque A; Sharma A; Divall P; Singh H
    Am J Sports Med; 2022 Jan; 50(1):264-272. PubMed ID: 33740395
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The use of suture-tape and suture-wire in arthroscopic rotator cuff repair: A comparative biomechanics study.
    Huntington L; Coles-Black J; Richardson M; Sobol T; Caldow J; Chuen J; Ackland DC
    Injury; 2018 Nov; 49(11):2047-2052. PubMed ID: 30224178
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of knotless wide suture double-row SutureBridge rotator cuff repair to double-row standard suture repair.
    Liu VK; Bouwmeester TM; Smith GCS; Lam PH
    J Shoulder Elbow Surg; 2020 Aug; 29(8):1621-1626. PubMed ID: 32217061
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The optimum tension for bridging sutures in transosseous-equivalent rotator cuff repair: a cadaveric biomechanical study.
    Park JS; McGarry MH; Campbell ST; Seo HJ; Lee YS; Kim SH; Lee TQ; Oh JH
    Am J Sports Med; 2015 Sep; 43(9):2118-25. PubMed ID: 26150589
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-Strength Suture Tapes Are Biomechanically Stronger Than High-Strength Sutures Used in Rotator Cuff Repair.
    Borbas P; Fischer L; Ernstbrunner L; Hoch A; Bachmann E; Bouaicha S; Wieser K
    Arthrosc Sports Med Rehabil; 2021 Jun; 3(3):e873-e880. PubMed ID: 34195657
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two Techniques for Treating Medium-Sized Supraspinatus Tears: The Medially Based Single-Row Technique and the Suture Bridge Technique.
    Yamakado K
    JBJS Essent Surg Tech; 2021; 11(2):. PubMed ID: 34277130
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Knotted and knotless double row transosseous equivalent repair techniques for arthroscopic rotator cuff repair demonstrate comparable post-operative outcomes.
    Fox MA; Hughes JD; Drain NP; Wagala N; Patel N; Nazzal E; Popchak A; Sabsevari S; Lesniak BP; Lin A
    Knee Surg Sports Traumatol Arthrosc; 2023 May; 31(5):1919-1924. PubMed ID: 35996032
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors predicting rotator cuff retears: an analysis of 1000 consecutive rotator cuff repairs.
    Le BT; Wu XL; Lam PH; Murrell GA
    Am J Sports Med; 2014 May; 42(5):1134-42. PubMed ID: 24748610
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The biomechanical effects of polytetrafluoroethylene suture augmentations in lateral-row rotator cuff repairs in an ovine model.
    Beimers L; Lam PH; Murrell GA
    J Shoulder Elbow Surg; 2014 Oct; 23(10):1545-52. PubMed ID: 24766792
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained?
    Cho NS; Lee BG; Rhee YG
    Am J Sports Med; 2011 Oct; 39(10):2108-16. PubMed ID: 21350064
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rotator cuff repair with bioabsorbable screws: An in vivo and ex vivo investigation.
    Cummins CA; Strickland S; Appleyard RC; Szomor ZL; Marshall J; Murrell GA
    Arthroscopy; 2003 Mar; 19(3):239-48. PubMed ID: 12627147
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rotator cuff repair with a novel mesh suture: An ex vivo assessment of mechanical properties.
    Zhang T; Hatta T; Thoreson AR; Lu C; Steinmann SP; Moran SL; Zhao C
    J Orthop Res; 2018 Mar; 36(3):987-992. PubMed ID: 28762567
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.
    Barber FA; Drew OR
    Arthroscopy; 2012 Sep; 28(9):1197-205. PubMed ID: 22592123
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical validation of load-sharing rip-stop fixation for the repair of tissue-deficient rotator cuff tears.
    Burkhart SS; Denard PJ; Konicek J; Hanypsiak BT
    Am J Sports Med; 2014 Feb; 42(2):457-62. PubMed ID: 24375848
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Knotless double-row SutureBridge rotator cuff repairs have improved self-reinforcement compared with double-row SutureBridge repairs with tied medial knots: a biomechanical study using an ovine model.
    Smith GCS; Bouwmeester TM; Lam PH
    J Shoulder Elbow Surg; 2017 Dec; 26(12):2206-2212. PubMed ID: 28935379
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Double-Layer Rotator Cuff Repair: Anatomic Reconstruction of the Superior Capsule and Rotator Cuff Improves Biomechanical Properties in Repairs of Delaminated Rotator Cuff Tears.
    Pauzenberger L; Heuberer PR; Dyrna F; Obopilwe E; Kriegleder B; Anderl W; Mazzocca AD
    Am J Sports Med; 2018 Nov; 46(13):3165-3173. PubMed ID: 30285460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Triple-Loaded Suture Anchors Versus a Knotless Rip Stop Construct in a Single-Row Rotator Cuff Repair Model.
    Noyes MP; Lederman E; Adams CR; Denard PJ
    Arthroscopy; 2018 May; 34(5):1414-1420. PubMed ID: 29456064
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique.
    Rhee YG; Cho NS; Parke CS
    Am J Sports Med; 2012 Nov; 40(11):2440-7. PubMed ID: 23002202
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Delaminated Rotator Cuff Tears Showed Lower Short-term Retear Rates After Arthroscopic Double-Layer Repair Versus Bursal Layer-Only Repair: A Randomized Controlled Trial.
    Heuberer PR; Pauzenberger L; Gruber MS; Ostermann RC; Hexel M; Laky B; Anderl W
    Am J Sports Med; 2020 Mar; 48(3):689-696. PubMed ID: 31917608
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.