These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 28452908)

  • 1. Measurement of Oxygen Consumption Variations in Critically Ill Burns Patients: Are the Fick Method and Indirect Calorimetry Interchangeable?
    Soussi S; Vallée F; Roquet F; Bevilacqua V; Benyamina M; Ferry A; Cupaciu A; Chaussard M; De Tymowski C; Boccara D; Mimoun M; Chaouat M; Anstey J; Mebazaa A; Legrand M;
    Shock; 2017 Nov; 48(5):532-538. PubMed ID: 28452908
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
    Chang AC; Kulik TJ; Hickey PR; Wessel DL
    Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry.
    Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E
    Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Inverse fick's principle in comparison to measurements of oxygen consumption in respiratory gases. Does intrapulmonary oxygen uptake account for differences shown by different system methods?].
    Weyland A; Weyland W; Sydow M; Weyland C; Kettler D
    Anaesthesist; 1994 Oct; 43(10):658-66. PubMed ID: 7818047
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lack of agreement between thermodilution and fick cardiac output in critically ill patients.
    Dhingra VK; Fenwick JC; Walley KR; Chittock DR; Ronco JJ
    Chest; 2002 Sep; 122(3):990-7. PubMed ID: 12226045
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure.
    Walsh TS; Hopton P; Lee A
    Crit Care Med; 1998 Jul; 26(7):1200-7. PubMed ID: 9671369
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Oxygen consumption by indirect calorimetry and Fick equation in swine: role of cardiac output].
    Ozier Y; Grosse H; Baudin F; Urbani L; Gomola A; Conseiller C; Cardoso J
    Ann Fr Anesth Reanim; 1997; 16(2):131-7. PubMed ID: 9686074
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor.
    Brandi LS; Bertolini R; Pieri M; Giunta F; Calafà M
    Intensive Care Med; 1997 Aug; 23(8):908-15. PubMed ID: 9310812
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.
    Valtier B; Cholley BP; Belot JP; de la Coussaye JE; Mateo J; Payen DM
    Am J Respir Crit Care Med; 1998 Jul; 158(1):77-83. PubMed ID: 9655710
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Indirect Calorimetry Overestimates Oxygen Consumption in Young Children: Caution is Advised Using Direct Fick Method as a Reference Method in Cardiac Output Comparison Studies.
    Sigurdsson TS; Lindberg L
    Pediatr Cardiol; 2020 Jan; 41(1):149-154. PubMed ID: 31741015
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of oxygen uptake and delivery in critically ill patients: a statistical reappraisal.
    Hanique G; Dugernier T; Laterre PF; Roeseler J; Dougnac A; Reynaert MS
    Intensive Care Med; 1994; 20(1):19-26. PubMed ID: 8163753
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of methods of measurements of oxygen consumption in mechanically ventilated patients with multiple trauma: the Fick method versus indirect calorimetry.
    Epstein CD; Peerless JR; Martin JE; Malangoni MA
    Crit Care Med; 2000 May; 28(5):1363-9. PubMed ID: 10834679
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of PulsioFlex® uncalibrated pulse contour method and a modified Fick principle with transpulmonary thermodilution measurements in critically ill patients.
    Grensemann J; Defosse JM; Wieland C; Wild UW; Wappler F; Sakka SG
    Anaesth Intensive Care; 2016 Jul; 44(4):484-90. PubMed ID: 27456179
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliability of cardiac output calculation by the fick principle and central venous oxygen saturation in emergency conditions.
    Weinbroum AA; Biderman P; Soffer D; Klausner JM; Szold O
    J Clin Monit Comput; 2008 Oct; 22(5):361-6. PubMed ID: 18946716
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spirometric versus Fick-derived oxygen consumption: which method is better?
    Thrush DN
    Crit Care Med; 1996 Jan; 24(1):91-5. PubMed ID: 8565545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measured pulmonary oxygen consumption: difference between systemic oxygen uptake measured by the reverse Fick method and indirect calorimetry in cardiac surgery.
    Peyton PJ; Robinson GJ
    Anaesthesia; 2005 Feb; 60(2):146-50. PubMed ID: 15644011
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients.
    Gonzalez J; Delafosse C; Fartoukh M; Capderou A; Straus C; Zelter M; Derenne JP; Similowski T
    Crit Care; 2003 Apr; 7(2):171-8. PubMed ID: 12720564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Correlation between oxygen consumption calculated using Fick's method and measured with indirect calorimetry in critically ill patients.
    Marson F; Auxiliadora Martins M; Coletto FA; Campos AD; Basile-Filho A
    Arq Bras Cardiol; 2004 Jan; 82(1):77-81, 72-6. PubMed ID: 14978596
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring cardiac output in critically Ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods.
    Sherman MS; Kosinski R; Paz HL; Campbell D
    Cardiology; 1997; 88(1):19-25. PubMed ID: 8960620
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calculated versus measured oxygen consumption during and after cardiac surgery. Is it possible to estimate lung oxygen consumption?
    Keinänen O; Takala J
    Acta Anaesthesiol Scand; 1997 Aug; 41(7):803-9. PubMed ID: 9265920
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.