These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Why the Diabetes Technology Society Surveillance Protocol for Glucose Meters Needs to Be Revised. Krouwer JS J Diabetes Sci Technol; 2017 Nov; 11(6):1247-1249. PubMed ID: 28376646 [TBL] [Abstract][Full Text] [Related]
3. System Accuracy Evaluation of Different Blood Glucose Monitoring Systems Following ISO 15197:2013 by Using Two Different Comparison Methods. Freckmann G; Link M; Schmid C; Pleus S; Baumstark A; Haug C Diabetes Technol Ther; 2015 Sep; 17(9):635-48. PubMed ID: 26110670 [TBL] [Abstract][Full Text] [Related]
4. Assessment of System Accuracy, Intermediate Measurement Precision, and Measurement Repeatability of a Blood Glucose Monitoring System Based on ISO 15197. Jendrike N; Baumstark A; Pleus S; Mende J; Haug C; Freckmann G J Diabetes Sci Technol; 2019 Mar; 13(2):235-241. PubMed ID: 30547683 [TBL] [Abstract][Full Text] [Related]
5. Seven-Year Surveillance of the Clinical Performance of a Blood Glucose Test Strip Product. Setford S; Grady M; Phillips S; Miller L; Mackintosh S; Cameron H; Corrigall K J Diabetes Sci Technol; 2017 Nov; 11(6):1155-1162. PubMed ID: 28406040 [TBL] [Abstract][Full Text] [Related]
6. Accuracy Evaluation of a CE-Marked System for Self-Monitoring of Blood Glucose With Three Reagent System Lots Following ISO 15197:2013. Salzsieder E; Berg S J Diabetes Sci Technol; 2015 Sep; 10(1):238-9. PubMed ID: 26394775 [No Abstract] [Full Text] [Related]
7. Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations. Freckmann G; Schmid C; Baumstark A; Rutschmann M; Haug C; Heinemann L J Diabetes Sci Technol; 2015 Jul; 9(4):885-94. PubMed ID: 25872965 [TBL] [Abstract][Full Text] [Related]
8. The accuracy evaluation of four blood glucose monitoring systems according to ISO 15197:2003 and ISO 15197:2013 criteria. Chen H; Yao Q; Dong Y; Tang Z; Li R; Cai B; Wang R; Chen Q Prim Care Diabetes; 2019 Jun; 13(3):252-258. PubMed ID: 30770203 [TBL] [Abstract][Full Text] [Related]
9. Design, fabrication, and feasibility analysis of a colorimetric detection system with a smartphone for self-monitoring blood glucose. Wang HC; Chang FY; Tsai TM; Chen CH; Chen YY J Biomed Opt; 2019 Feb; 24(2):1-7. PubMed ID: 30793568 [TBL] [Abstract][Full Text] [Related]
10. Accuracy Evaluation of Two Blood Glucose Monitoring Systems Following ISO 15197:2013. Berti F; Scuffi C; Valgimigli F J Diabetes Sci Technol; 2015 Jul; 9(6):1354-6. PubMed ID: 26224761 [No Abstract] [Full Text] [Related]
11. Evaluation of Four Blood Glucose Monitoring Systems for Self-Testing with Built-in Insulin Dose Advisor Based on ISO 15197:2013: System Accuracy and Hematocrit Influence. Jendrike N; Baumstark A; Pleus S; Liebing C; Beer A; Flacke F; Haug C; Freckmann G Diabetes Technol Ther; 2018 Apr; 20(4):303-313. PubMed ID: 29664706 [TBL] [Abstract][Full Text] [Related]
12. ISO 15197: 2013 Evaluation of a Blood Glucose Monitoring System's Measurement Accuracy. Jendrike N; Baumstark A; Kamecke U; Haug C; Freckmann G J Diabetes Sci Technol; 2017 Nov; 11(6):1275-1276. PubMed ID: 28849677 [No Abstract] [Full Text] [Related]
13. Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197. Freckmann G; Pleus S; Link M; Baumstark A; Schmid C; Högel J; Haug C Diabetes Technol Ther; 2015 Sep; 17(9):625-34. PubMed ID: 26062008 [TBL] [Abstract][Full Text] [Related]
15. A Low-Cost Inkjet-Printed Glucose Test Strip System for Resource-Poor Settings. Gainey Wilson K; Ovington P; Dean D J Diabetes Sci Technol; 2015 Jun; 9(6):1275-81. PubMed ID: 26071426 [TBL] [Abstract][Full Text] [Related]
16. Analytical performance of glucose monitoring systems at different blood glucose ranges and analysis of outliers in a clinical setting. Hasslacher C; Kulozik F; Platten I J Diabetes Sci Technol; 2014 May; 8(3):466-72. PubMed ID: 24876607 [TBL] [Abstract][Full Text] [Related]
17. New Generation Blood Glucose Monitoring System Exceeds International Accuracy Standards. Brazg RL; Klaff LJ; Sussman AM J Diabetes Sci Technol; 2016 Nov; 10(6):1414-1415. PubMed ID: 27271844 [No Abstract] [Full Text] [Related]
18. Improved Accuracy of Continuous Glucose Monitoring Systems in Pediatric Patients with Diabetes Mellitus: Results from Two Studies. Laffel L Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S223-33. PubMed ID: 26784126 [TBL] [Abstract][Full Text] [Related]
19. Accuracy and precision assessment of a new blood glucose monitoring system. Ji LN; Guo LX; Liu LB Clin Chem Lab Med; 2016 Jan; 54(1):181-8. PubMed ID: 26053011 [TBL] [Abstract][Full Text] [Related]
20. ISO 15197:2013 Accuracy Evaluation of Two CE-Marked Systems for Self-Monitoring of Blood Glucose. Jendrike N; Rittmeyer D; Pleus S; Baumstark A; Haug C; Freckmann G J Diabetes Sci Technol; 2015 Jul; 9(4):934-5. PubMed ID: 25901021 [No Abstract] [Full Text] [Related] [Next] [New Search]