  • 1. Analysis of Explanted Magnetically Controlled Growing Rods From Seven UK Spinal Centers.
    Joyce TJ; Smith SL; Rushton PRP; Bowey AJ; Gibson MJ
    Spine (Phila Pa 1976); 2018 Jan; 43(1):E16-E22. PubMed ID: 28459777
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The MAGEC system for spinal lengthening in children with scoliosis: A NICE Medical Technology Guidance.
    Jenks M; Craig J; Higgins J; Willits I; Barata T; Wood H; Kimpton C; Sims A
    Appl Health Econ Health Policy; 2014 Dec; 12(6):587-99. PubMed ID: 25172432
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Performance of MAGEC X Spine Rods: A Comparative Retrieval Study.
    Tognini M; Hothi H; Bergiers S; Shafafy M; Tucker S; Broomfield E; Henckel J; Hart A
    Global Spine J; 2024 Jan; 14(1):122-129. PubMed ID: 35446173
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rod Fracture in Magnetically Controlled Growing Spine Rods.
    Tognini M; Hothi H; Bergiers S; Broomfield E; Tucker S; Henckel J; Hart A
    J Pediatr Orthop; 2023 Apr; 43(4):211-217. PubMed ID: 36737055
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic Controlled Growth Rods in the Treatment of Scoliosis: Safety, Efficacy and Patient Selection.
    Tsirikos AI; Roberts SB
    Med Devices (Auckl); 2020; 13():75-85. PubMed ID: 32256128
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical Analysis of Explanted Telescopic Rods in the Management of Osteogenesis Imperfecta: A Multicenter Study.
    Nicolaou N; Luo Q; Giles SN; Maruthainar K; Kitchen MP; Thomas S; Fernandes JA; Roposch A
    J Pediatr Orthop; 2021 Jul; 41(6):e448-e456. PubMed ID: 33734203
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetically Controlled Growing Rods for Early-Onset Scoliosis: 2-Dimensional Operative Video.
    Chamberlin K; Galgano M; Grabala P
    Oper Neurosurg (Hagerstown); 2023 Nov; 25(5):e279. PubMed ID: 37499239
    [No Abstract]   [Full Text] [Related]  

  • 8. Comment on Grabala et al. Radiological Outcomes of Magnetically Controlled Growing Rods for the Treatment of Children with Various Etiologies of Early-Onset Scoliosis-A Multicenter Study.
    Tabeling CS; Lemans JVC; Kruyt MC
    J Clin Med; 2024 Apr; 13(8):. PubMed ID: 38673707
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetically controlled growing rods in the treatment of early-onset scoliosis: a note of caution.
    Rushton PRP; Siddique I; Crawford R; Birch N; Gibson MJ; Hutton MJ
    Bone Joint J; 2017 Jun; 99-B(6):708-713. PubMed ID: 28566388
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Systematic review of the complications associated with magnetically controlled growing rods for the treatment of early onset scoliosis.
    Thakar C; Kieser DC; Mardare M; Haleem S; Fairbank J; Nnadi C
    Eur Spine J; 2018 Sep; 27(9):2062-2071. PubMed ID: 29675673
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Force Testing of Explanted Magnetically Controlled Growing Rods.
    Rushton PRP; Smith SL; Forbes L; Bowey AJ; Gibson MJ; Joyce TJ
    Spine (Phila Pa 1976); 2019 Feb; 44(4):233-239. PubMed ID: 30044365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spinal Lengthening With Magnetically Controlled Growing Rods: Data From the Largest Series of Explanted Devices.
    Rushton PRP; Smith SL; Kandemir G; Forbes L; Fender D; Bowey AJ; Gibson MJ; Joyce TJ
    Spine (Phila Pa 1976); 2020 Feb; 45(3):170-176. PubMed ID: 31513114
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Health-Related Quality of Life in Early-Onset Scoliosis Patients Treated Surgically: EOSQ Scores in Traditional Growing Rod Versus Magnetically Controlled Growing Rods.
    Doany ME; Olgun ZD; Kinikli GI; Bekmez S; Kocyigit A; Demirkiran G; Karaagaoglu AE; Yazici M
    Spine (Phila Pa 1976); 2018 Jan; 43(2):148-153. PubMed ID: 28604490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The NuVasive MAGEC Rod Urgent Field Safety Notice Concerning Locking Pin Fracture: How Does Data From an Independent Explant Center Compare?
    Joyce TJ; Smith SL; Kandemir G; Rushton PRP; Fender D; Bowey AJ; Gibson MJ
    Spine (Phila Pa 1976); 2020 Jul; 45(13):872-876. PubMed ID: 32539289
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Unplanned Reoperations in Magnetically Controlled Growing Rod Surgery for Early Onset Scoliosis With a Minimum of Two-Year Follow-Up.
    Kwan KYH; Alanay A; Yazici M; Demirkiran G; Helenius I; Nnadi C; Ferguson J; Akbarnia BA; Cheung JPY; Cheung KMC
    Spine (Phila Pa 1976); 2017 Dec; 42(24):E1410-E1414. PubMed ID: 28658035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Traditional growing rod versus magnetically controlled growing rod for treatment of early onset scoliosis: Cost analysis from implantation till skeletal maturity.
    Wong CKH; Cheung JPY; Cheung PWH; Lam CLK; Cheung KMC
    J Orthop Surg (Hong Kong); 2017; 25(2):2309499017705022. PubMed ID: 28481128
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetically controlled growing rods in early onset scoliosis : Indications, timing and treatment.
    Akbarnia BA; Mundis GM
    Orthopade; 2019 Jun; 48(6):477-485. PubMed ID: 31172228
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Current status of the magnetically controlled growing rod in treatment of early-onset scoliosis: What we know after a decade of experience.
    Cheung JPY; Cheung KM
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019886945. PubMed ID: 31797729
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical wear analysis helps understand a mechanism of failure in retrieved magnetically controlled growing rods: a retrieval study.
    Wei JZ; Hothi HS; Morganti H; Bergiers S; Dal Gal E; Likcani D; Henckel J; Hart AJ
    BMC Musculoskelet Disord; 2020 Aug; 21(1):519. PubMed ID: 32758204
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Device-Related Complications Associated with Magec Rod Usage for Distraction-Based Correction of Scoliosis.
    Agarwal A; Kelkar A; Garg Agarwal A; Jayaswal D; Jayaswal A; Shendge V
    Spine Surg Relat Res; 2020; 4(2):148-151. PubMed ID: 32405561
    [TBL] [Abstract][Full Text] [Related]  