132 related articles for article (PubMed ID: 28462867)
1. Monte Carlo dose calculation in presence of low-density media: Application to lung SBRT treated during DIBH.
Beilla S; Younes T; Vieillevigne L; Bardies M; Franceries X; Simon L
Phys Med; 2017 Sep; 41():46-52. PubMed ID: 28462867
[TBL] [Abstract][Full Text] [Related]
2. Monte Carlo calculations support organ sparing in Deep-Inspiration Breath-Hold intensity-modulated radiotherapy for locally advanced lung cancer.
Ottosson W; Sibolt P; Larsen C; Lykkegaard Andersen JA; Borissova S; Mellemgaard A; Behrens CF
Radiother Oncol; 2015 Oct; 117(1):55-63. PubMed ID: 26385266
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer.
Tsuruta Y; Nakata M; Nakamura M; Matsuo Y; Higashimura K; Monzen H; Mizowaki T; Hiraoka M
Med Phys; 2014 Aug; 41(8):081715. PubMed ID: 25086525
[TBL] [Abstract][Full Text] [Related]
4. Advanced dose calculation algorithms in lung cancer radiotherapy: Implications for SBRT and locally advanced disease in deep inspiration breath hold.
Josipovic M; Persson GF; Rydhög JS; Smulders B; Thomsen JB; Aznar MC
Phys Med; 2018 Dec; 56():50-57. PubMed ID: 30527089
[TBL] [Abstract][Full Text] [Related]
5. Still equivalent for dose calculation in the Monte Carlo era? A comparison of free breathing and average intensity projection CT datasets for lung SBRT using three generations of dose calculation algorithms.
Zvolanek K; Ma R; Zhou C; Liang X; Wang S; Verma V; Zhu X; Zhang Q; Driewer J; Lin C; Zhen W; Wahl A; Zhou SM; Zheng D
Med Phys; 2017 May; 44(5):1939-1947. PubMed ID: 28273341
[TBL] [Abstract][Full Text] [Related]
6. Dependence of volume dose indices on dose calculation algorithms for VMAT-SBRT plans for peripheral lung tumor.
Matsuoka T; Araki F; Ohno T; Sakata J; Tominaga H
Med Dosim; 2019 Autumn; 44(3):284-290. PubMed ID: 30455092
[TBL] [Abstract][Full Text] [Related]
7. Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions.
Ojala JJ; Kapanen MK; Hyödynmaa SJ; Wigren TK; Pitkänen MA
J Appl Clin Med Phys; 2014 Mar; 15(2):4662. PubMed ID: 24710454
[TBL] [Abstract][Full Text] [Related]
8. SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems.
Panettieri V; Wennberg B; Gagliardi G; Duch MA; Ginjaume M; Lax I
Phys Med Biol; 2007 Jul; 52(14):4265-81. PubMed ID: 17664607
[TBL] [Abstract][Full Text] [Related]
9. On the use of a convolution-superposition algorithm for plan checking in lung stereotactic body radiation therapy.
Hardcastle N; Oborn BM; Haworth A
J Appl Clin Med Phys; 2016 Sep; 17(5):99-110. PubMed ID: 27685114
[TBL] [Abstract][Full Text] [Related]
10. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
11. Clinical verification of treatment planning dose calculation in lung SBRT with GATE Monte Carlo simulation code.
Ruiz Boiset G; V S Batista D; Coutinho Cardoso S
Phys Med; 2021 Jul; 87():1-10. PubMed ID: 34091196
[TBL] [Abstract][Full Text] [Related]
12. Monte Carlo validation of the TrueBeam 10XFFF phase-space files for applications in lung SABR.
Teke T; Duzenli C; Bergman A; Viel F; Atwal P; Gete E
Med Phys; 2015 Dec; 42(12):6863-74. PubMed ID: 26632043
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of an analytic linear Boltzmann transport equation solver for high-density inhomogeneities.
Lloyd SA; Ansbacher W
Med Phys; 2013 Jan; 40(1):011707. PubMed ID: 23298077
[TBL] [Abstract][Full Text] [Related]
14. Technical and dosimetric implications of respiratory induced density variations in a heterogeneous lung phantom.
Mohatt DJ; Ma T; Wiant DB; Islam NM; Gomez J; Singh AK; Malhotra HK
Radiat Oncol; 2018 Sep; 13(1):165. PubMed ID: 30180894
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc(®) stereotactic treatments.
Fogliata A; Nicolini G; Clivio A; Vanetti E; Cozzi L
Med Phys; 2011 Nov; 38(11):6228-37. PubMed ID: 22047388
[TBL] [Abstract][Full Text] [Related]
16. A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.
Gete E; Duzenli C; Milette MP; Mestrovic A; Hyde D; Bergman AM; Teke T
Med Phys; 2013 Feb; 40(2):021707. PubMed ID: 23387730
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo as a tool to evaluate the effect of different lung densities on radiotherapy dose distribution.
Caccia B; Andenna C; Iaccarino G; Landoni V; Soriani A; Occhigrossi A; Esposito A; Petetti E; Valentini S; Strigari L
Radiat Prot Dosimetry; 2014 Nov; 162(1-2):115-9. PubMed ID: 25452329
[TBL] [Abstract][Full Text] [Related]
18. Clinical implementation and evaluation of the Acuros dose calculation algorithm.
Yan C; Combine AG; Bednarz G; Lalonde RJ; Hu B; Dickens K; Wynn R; Pavord DC; Saiful Huq M
J Appl Clin Med Phys; 2017 Sep; 18(5):195-209. PubMed ID: 28834214
[TBL] [Abstract][Full Text] [Related]
19. SU-E-T-485: Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods.
Bush K; Wang L; Mok E
Med Phys; 2012 Jun; 39(6Part17):3816-3817. PubMed ID: 28517440
[TBL] [Abstract][Full Text] [Related]
20. An in vivo dose verification method for SBRT-VMAT delivery using the EPID.
McCowan PM; Van Uytven E; Van Beek T; Asuni G; McCurdy BM
Med Phys; 2015 Dec; 42(12):6955-63. PubMed ID: 26632051
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]