712 related articles for article (PubMed ID: 28474255)
1. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children.
Shellikeri S; Setser RM; Hwang TJ; Srinivasan A; Krishnamurthy G; Vatsky S; Girard E; Zhu X; Keller MS; Cahill AM
Pediatr Radiol; 2017 Jul; 47(8):963-973. PubMed ID: 28474255
[TBL] [Abstract][Full Text] [Related]
2. Prospective evaluation of MR overlay on real-time fluoroscopy for percutaneous extremity biopsies of bone lesions visible on MRI but not on CT in children in the interventional radiology suite.
Shellikeri S; Setser RM; Vatsky S; Srinivasan A; Krishnamurthy G; Zhu X; Keller MS; Cahill AM
Pediatr Radiol; 2018 Feb; 48(2):270-278. PubMed ID: 29128920
[TBL] [Abstract][Full Text] [Related]
3. Reduced-dose C-arm computed tomography applications at a pediatric institution.
Acord M; Shellikeri S; Vatsky S; Srinivasan A; Krishnamurthy G; Keller MS; Cahill AM
Pediatr Radiol; 2017 Dec; 47(13):1817-1824. PubMed ID: 28983677
[TBL] [Abstract][Full Text] [Related]
4. Pediatric Percutaneous Osteoid Osteoma Ablation: Cone-Beam CT with Fluoroscopic Overlay Versus Conventional CT Guidance.
Perry BC; Monroe EJ; McKay T; Kanal KM; Shivaram G
Cardiovasc Intervent Radiol; 2017 Oct; 40(10):1593-1599. PubMed ID: 28497188
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial.
Rouchy RC; Moreau-Gaudry A; Chipon E; Aubry S; Pazart L; Lapuyade B; Durand M; Hajjam M; Pottier S; Renard B; Logier R; Orry X; Cherifi A; Quehen E; Kervio G; Favelle O; Patat F; De Kerviler E; Hughes C; Medici M; Ghelfi J; Mounier A; Bricault I
Trials; 2017 Jul; 18(1):306. PubMed ID: 28683837
[TBL] [Abstract][Full Text] [Related]
6. Percutaneous bone biopsies: comparison between flat-panel cone-beam CT and CT-scan guidance.
Tselikas L; Joskin J; Roquet F; Farouil G; Dreuil S; Hakimé A; Teriitehau C; Auperin A; de Baere T; Deschamps F
Cardiovasc Intervent Radiol; 2015 Feb; 38(1):167-76. PubMed ID: 24627161
[TBL] [Abstract][Full Text] [Related]
7. Flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy of small (≤3 cm) pulmonary lesions.
Jiao DC; Li ZM; Yuan HF; Zhang QH; Ren JZ; Zhou PL; Wu G; Han XW
Acta Radiol; 2016 Jun; 57(6):677-83. PubMed ID: 26377260
[TBL] [Abstract][Full Text] [Related]
8. Helical CT versus intermittent CT fluoroscopic guidance for musculoskeletal needle biopsies: impact on radiation exposure, procedure time, diagnostic yield, and adverse events.
Cahalane AM; Habibollahi S; Staffa SJ; Yang K; Fintelmann FJ; Chang CY
Skeletal Radiol; 2023 Jun; 52(6):1119-1126. PubMed ID: 36355218
[TBL] [Abstract][Full Text] [Related]
9. Comparison of CT and fluoroscopic guidance for lumbar puncture in an obese population with prior failed unguided attempt.
Brook AD; Burns J; Dauer E; Schoendfeld AH; Miller TS
J Neurointerv Surg; 2014 May; 6(4):324-8. PubMed ID: 23729498
[TBL] [Abstract][Full Text] [Related]
10. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.
Ben-Shlomo A; Cohen D; Bruckheimer E; Bachar GN; Konstantinovsky R; Birk E; Atar E
Cardiovasc Intervent Radiol; 2016 May; 39(5):732-739. PubMed ID: 26493824
[TBL] [Abstract][Full Text] [Related]
11. Intermittent CT fluoroscopic guided lung biopsy - Retrospective analysis of success rate, radiation exposure, complications and duration of procedure.
Gupta R; Sinha N; Kumar P; Bhadani P; Rai DK; Kumar S
J Xray Sci Technol; 2019; 27(2):287-296. PubMed ID: 30856147
[TBL] [Abstract][Full Text] [Related]
12. CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.
Paulson EK; Sheafor DH; Enterline DS; McAdams HP; Yoshizumi TT
Radiology; 2001 Jul; 220(1):161-7. PubMed ID: 11425990
[TBL] [Abstract][Full Text] [Related]
13. MRI-guided thoraco-abdominal percutaneous needle biopsy: our initial experience.
Corradini LG; Polidori T; Maresca L; Caruso D; Laghi A; Simonetti G; Stefanini M
Eur Radiol; 2023 Aug; 33(8):5719-5727. PubMed ID: 37256353
[TBL] [Abstract][Full Text] [Related]
14. Comparison of a Patient-Mounted Needle-Driving Robotic System versus Single-Rotation CT Fluoroscopy to Perform CT-Guided Percutaneous Lung Biopsies.
Alexander ES; Petre EN; Bodard S; Marinelli B; Sarkar D; Cornelis FH
J Vasc Interv Radiol; 2024 Jun; 35(6):859-864. PubMed ID: 38447771
[TBL] [Abstract][Full Text] [Related]
15. C-Arm Cone-Beam CT Combined with a New Electromagnetic Navigation System for Guidance of Percutaneous Needle Biopsies: Initial Clinical Experience.
Kickuth R; Reichling C; Bley T; Hahn D; Ritter C
Rofo; 2015 Jul; 187(7):569-76. PubMed ID: 26090650
[TBL] [Abstract][Full Text] [Related]
16. Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience.
Jiao D; Huang K; Wu G; Wang Y; Han X
Radiol Med; 2016 Oct; 121(10):769-79. PubMed ID: 27334008
[TBL] [Abstract][Full Text] [Related]
17. Flat detector C-arm CT-guided transthoracic needle biopsy of small (≤2.0 cm) pulmonary nodules: diagnostic accuracy and complication in 100 patients.
Jiao D; Yuan H; Zhang Q; Han X
Radiol Med; 2016 Apr; 121(4):268-78. PubMed ID: 26646263
[TBL] [Abstract][Full Text] [Related]
18. Cone-beam computed tomography guidance with navigational overlay for percutaneous lung nodule biopsy.
Shivaram GM; Gill AE; Monroe EJ; Koo KSH; Hawkins CM
Pediatr Radiol; 2019 Mar; 49(3):327-331. PubMed ID: 30411171
[TBL] [Abstract][Full Text] [Related]
19. Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.
Rotolo N; Floridi C; Imperatori A; Fontana F; Ierardi AM; Mangini M; Arlant V; De Marchi G; Novario R; Dominioni L; Fugazzola C; Carrafiello G
Eur Radiol; 2016 Feb; 26(2):381-9. PubMed ID: 26045345
[TBL] [Abstract][Full Text] [Related]
20. Radiation Dose Exposure for Lumbar Transforaminal Epidural Steroid Injections and Facet Joint Blocks Under CT vs. Fluoroscopic Guidance.
Maino P; Presilla S; Colli Franzone PA; van Kuijk SMJ; Perez RSGM; Koetsier E
Pain Pract; 2018 Jul; 18(6):798-804. PubMed ID: 29282848
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]