These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
212 related articles for article (PubMed ID: 28475107)
1. Evaluation of a novel therapeutic focused ultrasound transducer based on Fermat's spiral. Ramaekers P; de Greef M; Berriet R; Moonen CTW; Ries M Phys Med Biol; 2017 Jun; 62(12):5021-5045. PubMed ID: 28475107 [TBL] [Abstract][Full Text] [Related]
2. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation. Ramaekers P; Ries M; Moonen CT; de Greef M Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731 [TBL] [Abstract][Full Text] [Related]
3. Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model. Adams MS; Salgaonkar VA; Plata-Camargo J; Jones PD; Pascal-Tenorio A; Chen HY; Bouley DM; Sommer G; Pauly KB; Diederich CJ Med Phys; 2016 Jul; 43(7):4184. PubMed ID: 27370138 [TBL] [Abstract][Full Text] [Related]
4. A novel, flat, electronically-steered phased array transducer for tissue ablation: preliminary results. Ellens NP; Lucht BB; Gunaseelan ST; Hudson JM; Hynynen KH Phys Med Biol; 2015 Mar; 60(6):2195-215. PubMed ID: 25683789 [TBL] [Abstract][Full Text] [Related]
5. An MR-compliant phased-array HIFU transducer with augmented steering range, dedicated to abdominal thermotherapy. Auboiroux V; Dumont E; Petrusca L; Viallon M; Salomir R Phys Med Biol; 2011 Jun; 56(12):3563-82. PubMed ID: 21606558 [TBL] [Abstract][Full Text] [Related]
6. Histotripsy Lesion Formation Using an Ultrasound Imaging Probe Enabled by a Low-Frequency Pump Transducer. Lin KW; Hall TL; Xu Z; Cain CA Ultrasound Med Biol; 2015 Aug; 41(8):2148-60. PubMed ID: 25929995 [TBL] [Abstract][Full Text] [Related]
7. Numerical evaluation of the effect of electronically steering a phased array transducer: axially post-focal shifting. Wang M; Zhou Y Int J Hyperthermia; 2017 Nov; 33(7):758-769. PubMed ID: 28540816 [TBL] [Abstract][Full Text] [Related]
8. Variation of High-Intensity Therapeutic Ultrasound (HITU) Pressure Field Characterization: Effects of Hydrophone Choice, Nonlinearity, Spatial Averaging and Complex Deconvolution. Liu Y; Wear KA; Harris GR Ultrasound Med Biol; 2017 Oct; 43(10):2329-2342. PubMed ID: 28735734 [TBL] [Abstract][Full Text] [Related]
9. Method for Designing Multielement Fully Populated Random Phased Arrays for Ultrasound Surgery Applications. Rosnitskiy PB; Vysokanov BA; Gavrilov LR; Sapozhnikov OA; Khokhlova VA IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Apr; 65(4):630-637. PubMed ID: 29610092 [TBL] [Abstract][Full Text] [Related]
10. Integration of deployable fluid lenses and reflectors with endoluminal therapeutic ultrasound applicators: Preliminary investigations of enhanced penetration depth and focal gain. Adams MS; Salgaonkar VA; Scott SJ; Sommer G; Diederich CJ Med Phys; 2017 Oct; 44(10):5339-5356. PubMed ID: 28681404 [TBL] [Abstract][Full Text] [Related]
11. Quantitative assessment of acoustic intensity in the focused ultrasound field using hydrophone and infrared imaging. Yu Y; Shen G; Zhou Y; Bai J; Chen Y Ultrasound Med Biol; 2013 Nov; 39(11):2021-33. PubMed ID: 23972377 [TBL] [Abstract][Full Text] [Related]
12. Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: application to intercostal ablation in liver. Salomir R; Petrusca L; Auboiroux V; Muller A; Vargas MI; Morel DR; Goget T; Breguet R; Terraz S; Hopple J; Montet X; Becker CD; Viallon M Invest Radiol; 2013 Jun; 48(6):366-80. PubMed ID: 23344514 [TBL] [Abstract][Full Text] [Related]
13. Annular phased array transducer for preclinical testing of anti-cancer drug efficacy on small animals. Kujawska T; Secomski W; Byra M; Postema M; Nowicki A Ultrasonics; 2017 Apr; 76():92-98. PubMed ID: 28086110 [TBL] [Abstract][Full Text] [Related]
14. Feasibility of in vivo transesophageal cardiac ablation using a phased ultrasound array. Werner J; Park EJ; Lee H; Francischelli D; Smith NB Ultrasound Med Biol; 2010 May; 36(5):752-60. PubMed ID: 20347517 [TBL] [Abstract][Full Text] [Related]
15. Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor. Zhou Y Med Eng Phys; 2015 Mar; 37(3):335-40. PubMed ID: 25659300 [TBL] [Abstract][Full Text] [Related]
16. Design and characterization of a laterally mounted phased-array transducer breast-specific MRgHIFU device with integrated 11-channel receiver array. Payne A; Merrill R; Minalga E; Vyas U; de Bever J; Todd N; Hadley R; Dumont E; Neumayer L; Christensen D; Roemer R; Parker D Med Phys; 2012 Mar; 39(3):1552-60. PubMed ID: 22380387 [TBL] [Abstract][Full Text] [Related]
17. Calculating the Effect of Ribs on the Focus Quality of a Therapeutic Spherical Random Phased Array. Zubair M; Dickinson R Sensors (Basel); 2021 Feb; 21(4):. PubMed ID: 33572208 [TBL] [Abstract][Full Text] [Related]