These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 28482589)

  • 21. Osteoblast proliferation and differentiation on dentin slices are modulated by pretreatment of the surface with tetracycline or osteoclasts.
    Schwartz Z; Lohmann CH; Wieland M; Cochran DL; Dean DD; Textor M; Bonewald LF; Boyan BD
    J Periodontol; 2000 Apr; 71(4):586-97. PubMed ID: 10807123
    [TBL] [Abstract][Full Text] [Related]  

  • 22. On the role of Nb-related sites of an oxidized β-TiNb alloy surface in its interaction with osteoblast-like MG-63 cells.
    Jirka I; Vandrovcová M; Frank O; Tolde Z; Plšek J; Luxbacher T; Bačáková L; Starý V
    Mater Sci Eng C Mater Biol Appl; 2013 Apr; 33(3):1636-45. PubMed ID: 23827618
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The impact of diamond nanocrystallinity on osteoblast functions.
    Yang L; Sheldon BW; Webster TJ
    Biomaterials; 2009 Jul; 30(20):3458-65. PubMed ID: 19339049
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Histological and biochemical evaluation of osteoblasts cultured on bioactive glass, hydroxylapatite, titanium alloy, and stainless steel.
    Vrouwenvelder WC; Groot CG; de Groot K
    J Biomed Mater Res; 1993 Apr; 27(4):465-75. PubMed ID: 8385144
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Enhanced adhesion of osteoblastic cells on polystyrene films by independent control of surface topography and wettability.
    Yang SY; Kim ES; Jeon G; Choi KY; Kim JK
    Mater Sci Eng C Mater Biol Appl; 2013 Apr; 33(3):1689-95. PubMed ID: 23827625
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Adhesion and differentiation of Saos-2 osteoblast-like cells on chromium-doped diamond-like carbon coatings.
    Filova E; Vandrovcova M; Jelinek M; Zemek J; Houdkova J; Jan Remsa ; Kocourek T; Stankova L; Bacakova L
    J Mater Sci Mater Med; 2017 Jan; 28(1):17. PubMed ID: 28000113
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Polysaccharide-protein surface modification of titanium via a layer-by-layer technique: characterization and cell behaviour aspects.
    Cai K; Rechtenbach A; Hao J; Bossert J; Jandt KD
    Biomaterials; 2005 Oct; 26(30):5960-71. PubMed ID: 15913761
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sol-gel-modified titanium with hydroxyapatite thin films and effect on osteoblast-like cell responses.
    Kim HW; Kim HE; Salih V; Knowles JC
    J Biomed Mater Res A; 2005 Sep; 74(3):294-305. PubMed ID: 16013054
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Surface modification of TiO
    Lai M; Jin Z; Su Z
    Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():490-497. PubMed ID: 28183637
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of nanocoating with rhamnogalacturonan-I on surface properties and osteoblasts response.
    Gurzawska K; Svava R; Syberg S; Yihua Y; Haugshøj KB; Damager I; Ulvskov P; Christensen LH; Gotfredsen K; Jørgensen NR
    J Biomed Mater Res A; 2012 Mar; 100(3):654-64. PubMed ID: 22213456
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Osteoblast behavior on various ultra short pulsed laser deposited surface coatings.
    Qu C; Myllymaa S; Prittinen J; Koistinen AP; Lappalainen R; Lammi MJ
    Mater Sci Eng C Mater Biol Appl; 2013 Apr; 33(3):1676-82. PubMed ID: 23827623
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Enhanced osteoblastic cell response on zirconia by bio-inspired surface modification.
    Liu YT; Lee TM; Lui TS
    Colloids Surf B Biointerfaces; 2013 Jun; 106():37-45. PubMed ID: 23434689
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Surface modification of titanium thin film with chitosan via electrostatic self-assembly technique and its influence on osteoblast growth behavior.
    Cai K; Hu Y; Jandt KD; Wang Y
    J Mater Sci Mater Med; 2008 Feb; 19(2):499-506. PubMed ID: 17619966
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biocompatibility and mechanical properties of diamond-like coatings on cobalt-chromium-molybdenum steel and titanium-aluminum-vanadium biomedical alloys.
    Hinüber C; Kleemann C; Friederichs RJ; Haubold L; Scheibe HJ; Schuelke T; Boehlert C; Baumann MJ
    J Biomed Mater Res A; 2010 Nov; 95(2):388-400. PubMed ID: 20648536
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Growth of a TiNb adhesion interlayer for bioactive coatings.
    Tolde Z; Starý V; Cvrček L; Vandrovcová M; Remsa J; Daniš S; Krčil J; Bačáková L; Špatenka P
    Mater Sci Eng C Mater Biol Appl; 2017 Nov; 80():652-658. PubMed ID: 28866212
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development of strontium and magnesium substituted porous hydroxyapatite/poly(3,4-ethylenedioxythiophene) coating on surgical grade stainless steel and its bioactivity on osteoblast cells.
    Gopi D; Ramya S; Rajeswari D; Surendiran M; Kavitha L
    Colloids Surf B Biointerfaces; 2014 Feb; 114():234-40. PubMed ID: 24200951
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of titanium implant surface nanoroughness and calcium phosphate low impregnation on bone cell activity in vitro.
    Bucci-Sabattini V; Cassinelli C; Coelho PG; Minnici A; Trani A; Dohan Ehrenfest DM
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2010 Feb; 109(2):217-24. PubMed ID: 20031453
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Enhanced osteoblast responses to poly ether ether ketone surface modified by water plasma immersion ion implantation.
    Wang H; Lu T; Meng F; Zhu H; Liu X
    Colloids Surf B Biointerfaces; 2014 May; 117():89-97. PubMed ID: 24632035
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Interaction of bovine serum albumin and lysozyme with stainless steel studied by time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy.
    Hedberg YS; Killian MS; Blomberg E; Virtanen S; Schmuki P; Odnevall Wallinder I
    Langmuir; 2012 Nov; 28(47):16306-17. PubMed ID: 23116183
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of operating parameters on surface properties of RF glow discharge oxygen plasma treated TiO₂/PET film for biomedical application.
    Pandiyaraj KN; Deshmukh RR; Mahendiran R; Su PG; Yassitepe E; Shah I; Perni S; Prokopovich P; Nadagouda MN
    Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():309-19. PubMed ID: 24433917
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.