These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. In vivo evaluation of the "TinyPump" as a pediatric left ventricular assist device. Kitao T; Ando Y; Yoshikawa M; Kobayashi M; Kimura T; Ohsawa H; Machida S; Yokoyama N; Sakota D; Konno T; Ishihara K; Takatani S Artif Organs; 2011 May; 35(5):543-53. PubMed ID: 21595723 [TBL] [Abstract][Full Text] [Related]
3. Pediatric ventricular assist devices: current challenges and future prospects. Burki S; Adachi I Vasc Health Risk Manag; 2017; 13():177-185. PubMed ID: 28546755 [TBL] [Abstract][Full Text] [Related]
5. Extended in vivo evaluation of a miniaturized axial flow pump with a novel inflow cannula for a minimal invasive implantation procedure. Schima H; Zrunek P; Stoiber M; Larose J; Shambaugh C; Tamez D; Deckert Z; Plasenzotti R; Bergmeister H; Wieselthaler G J Heart Lung Transplant; 2014 Apr; 33(4):422-8. PubMed ID: 24388396 [TBL] [Abstract][Full Text] [Related]
6. Design Concepts and Preclinical Results of a Miniaturized HeartWare Platform: The MVAD System. Cheung A; Chorpenning K; Tamez D; Shambaugh C; Dierlam AE; Taskin ME; Ashenuga M; Reyes C; LaRose JA Innovations (Phila); 2015; 10(3):151-6. PubMed ID: 26098174 [TBL] [Abstract][Full Text] [Related]
7. Miniaturized HIA microdiagonal pump as left ventricular assist device in a sheep model. Schmitto JD; Ortmann P; Akdis M; Alekuzei H; Steinke K; Kolat P; Popov AF; Liakopoulos OJ; Waldmann-Beushausen R; Mirzaie M; Grossmann M; Seipelt R; Schöndube FA ASAIO J; 2008; 54(3):233-6. PubMed ID: 18496271 [TBL] [Abstract][Full Text] [Related]
8. In vivo evaluation of the HeartWare MVAD Pump. McGee E; Chorpenning K; Brown MC; Breznock E; Larose JA; Tamez D J Heart Lung Transplant; 2014 Apr; 33(4):366-71. PubMed ID: 24238834 [TBL] [Abstract][Full Text] [Related]
9. In vivo evaluation of an implantable magnetic suspending left ventricular assist device. Lin C; Wu G; Liu X; Xu C; Hou X; Li H; Chen C; Yang P; Wang J; Liu Y Int J Artif Organs; 2015 Mar; 38(3):138-45. PubMed ID: 25837877 [TBL] [Abstract][Full Text] [Related]
10. Complications common to ventricular assist device support are rare with 90 days of DeBakey VAD support in calves. Fossum TW; Morley D; Olsen DB; Edwards J; Burns G; Miller MW; Franks J; Benkowski R; Thomas J; Benson P; Martinez E; Carroll G; Lynch B; Noon GP; DeBakey ME ASAIO J; 2001; 47(3):288-92. PubMed ID: 11374775 [TBL] [Abstract][Full Text] [Related]
11. Durability of left ventricular assist devices: Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 2006 to 2011. Holman WL; Naftel DC; Eckert CE; Kormos RL; Goldstein DJ; Kirklin JK J Thorac Cardiovasc Surg; 2013 Aug; 146(2):437-41.e1. PubMed ID: 23490245 [TBL] [Abstract][Full Text] [Related]
13. In vivo experimental testing of the FW axial blood pump for left ventricular support in Fu Wai Hospital. Zhang Y; Hu SS; Zhou JY; Sun HS; Tang Y; Zhang H; Zheng Z; Li GR; Zhu XD; Gui XM ASAIO J; 2009; 55(1):28-32. PubMed ID: 19092667 [TBL] [Abstract][Full Text] [Related]
14. Short-term in vivo performance of the Cleveland clinic PediPump left ventricular assist device. Fumoto H; Shiose A; Flick CR; Noble LD; Dudzinski DT; Casas F; Takaseya T; Arakawa Y; Fukamachi K; Smith WA; Duncan BW Artif Organs; 2014 May; 38(5):374-82. PubMed ID: 24118024 [TBL] [Abstract][Full Text] [Related]
15. Early in vivo experience with the pediatric Jarvik 2000 heart. Kilic A; Nolan TD; Li T; Yankey GK; Prastein DJ; Cheng G; Jarvik RK; Wu ZJ; Griffith BP ASAIO J; 2007; 53(3):374-8. PubMed ID: 17515732 [TBL] [Abstract][Full Text] [Related]
16. Chronic Ovine Studies Demonstrate Low Thromboembolic Risk in the Penn State Infant Ventricular Assist Device. Lukic B; Clark JB; Izer JM; Cooper TK; Finicle HA; Cysyk J; Doxtater B; Yeager E; Reibson J; Newswanger RK; Leibich P; Bletcher K; Weiss WJ ASAIO J; 2019; 65(4):371-379. PubMed ID: 30681440 [TBL] [Abstract][Full Text] [Related]
17. Preclinical Study of Anticoagulation Regimens in Sheep After Implantation of CH-VAD Blood Pump. Xu C; Wu G; Liu X; He Y; Hou X; Li H; Chen C; Yang P; Lin C Artif Organs; 2018 Sep; 42(9):891-898. PubMed ID: 27925225 [TBL] [Abstract][Full Text] [Related]