BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 28497537)

  • 1. ICSH recommendations for modified and alternate methods measuring the erythrocyte sedimentation rate.
    Kratz A; Plebani M; Peng M; Lee YK; McCafferty R; Machin SJ;
    Int J Lab Hematol; 2017 Oct; 39(5):448-457. PubMed ID: 28497537
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calibration and validation for erythrocyte sedimentation tests. Role of the International Committee on Standardization in Hematology reference procedure.
    Thomas RD; Westengard JC; Hay KL; Bull BS
    Arch Pathol Lab Med; 1993 Jul; 117(7):719-23. PubMed ID: 8323437
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ICSH recommendations for measurement of erythrocyte sedimentation rate. International Council for Standardization in Haematology (Expert Panel on Blood Rheology).
    J Clin Pathol; 1993 Mar; 46(3):198-203. PubMed ID: 8463411
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Test 1 analyser for determination of ESR. 1. Practical evaluation and comparison with the Westergren technique.
    Hardeman MR; Levitus M; Pelliccia A; Bouman AA
    Scand J Clin Lab Invest; 2010 Feb; 70(1):21-5. PubMed ID: 19929270
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical application of a new method for determination of the erythrocyte sedimentation rate using the BC-720 automated hematology analyzer.
    Shen Y; Liu D; Wang Y; Cao J; Zhang S; Wen H; Dong Q; Zheng D; Qiu J
    Int J Lab Hematol; 2023 Aug; 45(4):449-459. PubMed ID: 36912464
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method.
    Schapkaitz E; RabuRabu S; Engelbrecht M
    J Clin Lab Anal; 2019 Feb; 33(2):e22661. PubMed ID: 30152149
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Erythrocyte sedimentation rate (ESR) measured by the Streck ESR-Auto Plus is higher than with the Sediplast Westergren method: a validation study.
    Vennapusa B; De La Cruz L; Shah H; Michalski V; Zhang QY
    Am J Clin Pathol; 2011 Mar; 135(3):386-90. PubMed ID: 21350092
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of iSED and Ves-Matic Cube 200 Erythrocyte Sedimentation Rate Measurements With Westergren Method.
    Boğdaycioğlu N; Yilmaz FM; Sezer S; Oğuz E
    J Clin Lab Anal; 2015 Sep; 29(5):397-404. PubMed ID: 25131836
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy study of a novel alternate method measuring erythrocyte sedimentation rate for prototype hematology analyzer Celltac α.
    Maki R; Tabe Y; Yamamoto T; Takemura H; Sawada T; Esaki T; Higuchi M; Misawa S; Miyake K; Miida T; Nagai Y; Ohsaka A
    Int J Lab Hematol; 2021 Aug; 43(4):588-596. PubMed ID: 33929779
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Comparison Between the StaRRsed Auto-Compact Erythrocyte Sedimentation Rate Instrument and the Westergren Method.
    Horsti J; Rontu R; Collings A
    J Clin Med Res; 2010 Dec; 2(6):261-5. PubMed ID: 22043259
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differences in erythrocyte sedimentation rates using the Westergren method and a centrifugation method.
    Shelat SG; Chacosky D; Shibutani S
    Am J Clin Pathol; 2008 Jul; 130(1):127-30. PubMed ID: 18550481
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of Diesse Ves-matic automated system for measuring erythrocyte sedimentation rate.
    Caswell M; Stuart J
    J Clin Pathol; 1991 Nov; 44(11):946-9. PubMed ID: 1752986
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automated measurement of the erythrocyte sedimentation rate: method validation and comparison.
    Lapić I; Piva E; Spolaore F; Tosato F; Pelloso M; Plebani M
    Clin Chem Lab Med; 2019 Aug; 57(9):1364-1373. PubMed ID: 30939112
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Test-1 analyzer and conventional Westergren method for erythrocyte sedimentation rate: A comparative study between two laboratories.
    Sonmez C; Dogan OC; Kaymak AO; Akkaya N; Akin KO; Guntas G
    J Clin Lab Anal; 2018 Jun; 32(5):e22384. PubMed ID: 29341286
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analytical validation of the iSED automated analyzer for erythrocyte sedimentation rate.
    Lapić I; Miloš M; Tosato F; Piva E; Zadro R; Rogić D; Plebani M
    Int J Lab Hematol; 2020 Apr; 42(2):109-115. PubMed ID: 31725953
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the Ves-Matic Cube 200 erythrocyte sedimentation method: comparison with Westergren-based methods.
    Curvers J; Kooren J; Laan M; van Lierop E; van de Kerkhof D; Scharnhorst V; Herruer M
    Am J Clin Pathol; 2010 Oct; 134(4):653-60. PubMed ID: 20855647
    [TBL] [Abstract][Full Text] [Related]  

  • 17. ICSH review of the measurement of the erythocyte sedimentation rate.
    Jou JM; Lewis SM; Briggs C; Lee SH; De La Salle B; McFadden S;
    Int J Lab Hematol; 2011 Apr; 33(2):125-32. PubMed ID: 21352508
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-way comparison of methods for the measurement of the erythrocyte sedimentation rate.
    Mahlangu JN; Davids M
    J Clin Lab Anal; 2008; 22(5):346-52. PubMed ID: 18803269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyzer using the Westergren ESR method in patients with systemic inflammatory conditions.
    Happe MR; Battafarano DF; Dooley DP; Rennie TA; Murphy FT; Casey TJ; Ward JA
    Am J Clin Pathol; 2002 Jul; 118(1):14-7. PubMed ID: 12109848
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 13.