These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
189 related articles for article (PubMed ID: 28499653)
1. Customized Hinged Covered Metallic Stents for the Treatment of Benign Main Bronchial Stenosis. Han X; Al-Tariq Q; Zhao Y; Li L; Cheng Z; Wang H; Liu C; Jiao D; Wu G Ann Thorac Surg; 2017 Aug; 104(2):420-425. PubMed ID: 28499653 [TBL] [Abstract][Full Text] [Related]
2. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis. Ma J; Han X; Wu G; Jiao D; Ren K; Bi Y Cardiovasc Intervent Radiol; 2016 Aug; 39(8):1144-51. PubMed ID: 27146146 [TBL] [Abstract][Full Text] [Related]
3. Long-term follow-up of self-expandable metallic stents in benign tracheobronchial stenosis: a retrospective study. Xiong XF; Xu L; Fan LL; Cheng DY; Zheng BX BMC Pulm Med; 2019 Feb; 19(1):33. PubMed ID: 30736856 [TBL] [Abstract][Full Text] [Related]
4. Ultrathin Silicone Stent Placement for Adult Patients. Oki M; Saka H Ann Thorac Surg; 2021 Jul; 112(1):e69-e72. PubMed ID: 33662304 [TBL] [Abstract][Full Text] [Related]
5. Safety and Efficacy of a Fully Covered Self-Expandable Metallic Stent in Benign Airway Stenosis. Fortin M; Lacasse Y; Elharrar X; Tazi-Mezalek R; Laroumagne S; Guinde J; Astoul P; Dutau H Respiration; 2017; 93(6):430-435. PubMed ID: 28448981 [TBL] [Abstract][Full Text] [Related]
6. Removal of covered self-expandable metallic airway stents in benign disorders: indications, technique, and outcomes. Noppen M; Stratakos G; D'Haese J; Meysman M; Vinken W Chest; 2005 Feb; 127(2):482-7. PubMed ID: 15705985 [TBL] [Abstract][Full Text] [Related]
7. Use of balloon-expandable metallic stents in the management of bronchial stenosis and bronchomalacia after lung transplantation. Susanto I; Peters JI; Levine SM; Sako EY; Anzueto A; Bryan CL Chest; 1998 Nov; 114(5):1330-5. PubMed ID: 9824010 [TBL] [Abstract][Full Text] [Related]
8. Placement of covered retrievable expandable metallic stents for pediatric tracheobronchial obstruction. Shin JH; Hong SJ; Song HY; Park SJ; Ko GY; Lee SY; Kim HB; Jang JY J Vasc Interv Radiol; 2006 Feb; 17(2 Pt 1):309-17. PubMed ID: 16517777 [TBL] [Abstract][Full Text] [Related]
9. Successful Deployment of Two Balloon-Expandable Stents Using an In-Stent Bifurcating Approach. Cho RJ; Zamora FD; Gibson H; Dincer HE Ann Am Thorac Soc; 2018 Jul; 15(7):884-886. PubMed ID: 29957039 [No Abstract] [Full Text] [Related]
10. Bronchial stump fistula: treatment with covered, retrievable, expandable, hinged stents--preliminary clinical experience. Li YD; Han XW; Li MH; Wu G Acta Radiol; 2006 Nov; 47(9):922-6. PubMed ID: 17077041 [TBL] [Abstract][Full Text] [Related]
11. Treatment of mixed and refractory post-tuberculosis tracheobronchial stenosis with L-shaped silicone stents: case series and a literature review. Zhang C; Li W; Li Y; Fang N; Xu M; Ke L; Li L; Liu G Ther Adv Respir Dis; 2024; 18():17534666241254901. PubMed ID: 38785036 [TBL] [Abstract][Full Text] [Related]
12. Clinical Application of Fully Covered Self-Expandable Metal Stents in the Treatment of Bronchial Fistula. Cao M; Zhu Q; Wang W; Zhang TX; Jiang MZ; Zang Q Thorac Cardiovasc Surg; 2016 Sep; 64(6):533-9. PubMed ID: 25581102 [TBL] [Abstract][Full Text] [Related]
14. [Therapeutic efficacy analysis of bronchoscopic interventional therapy on severe tuberculous main bronchial stenosis complicated with unilateral atelectasis]. Li Y; Yao XP; Bai C; Huang Y; Wang Q; Zhao LJ; Dong YC; Teng HY; Li Q Zhonghua Jie He He Hu Xi Za Zhi; 2011 Jun; 34(6):454-8. PubMed ID: 21781520 [TBL] [Abstract][Full Text] [Related]
15. [Endoscopic retrieval of metallic stents in patients with airway diseases]. Wang HW; Zhou YZ; Li DM; Zou H; Li J; Zhang N Zhonghua Yi Xue Za Zhi; 2010 May; 90(20):1411-5. PubMed ID: 20646632 [TBL] [Abstract][Full Text] [Related]
16. [Clinical application of a fully covered self-expandable metallic stent in treatment of airway fistula]. Zhu Q; Zang Q; Jiang ZM; Wang W; Cao M Zhonghua Jie He He Hu Xi Za Zhi; 2013 Jun; 36(6):431-6. PubMed ID: 24103206 [TBL] [Abstract][Full Text] [Related]
17. The role of airway stenting in pediatric tracheobronchial obstruction. Antón-Pacheco JL; Cabezalí D; Tejedor R; López M; Luna C; Comas JV; de Miguel E Eur J Cardiothorac Surg; 2008 Jun; 33(6):1069-75. PubMed ID: 18299200 [TBL] [Abstract][Full Text] [Related]
18. Open surgery for removal of a failing Gianturco stent with reversed sleeve resection of the right middle and lower lobes. Kim J; Kim H; Kim K; Shim YM Eur J Cardiothorac Surg; 1998 Sep; 14(3):329-31. PubMed ID: 9761446 [TBL] [Abstract][Full Text] [Related]
19. Successful removal of expandable metallic stent in a patient with lung cancer. Ose N; Inoue M; Minami M; Sawabata N; Kadota Y; Okumura M Asian Cardiovasc Thorac Ann; 2012 Apr; 20(2):202-4. PubMed ID: 22499973 [TBL] [Abstract][Full Text] [Related]
20. [Endoscopic treatment of cicatricial stenoses of the 2-3 segmental bronchi]. Tsurova DK; Gasanov AM; Danielyan SN; Voskresensky OV; Tarabrin EA Khirurgiia (Mosk); 2017; (8):87-90. PubMed ID: 28805785 [No Abstract] [Full Text] [Related] [Next] [New Search]