These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 28506167)

  • 1. Two-dimensional Morphological Characteristics of the Distal Radius on Axial Magnetic Resonance Image and the Effects on Distal Screw Length.
    Park HY; Roh YT; Min DU; Song SW; Sur YJ
    J Hand Surg Asian Pac Vol; 2017 Jun; 22(2):167-173. PubMed ID: 28506167
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.
    Park DH; Goldie BS
    Tech Hand Up Extrem Surg; 2012 Sep; 16(3):169-72. PubMed ID: 22914000
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture.
    Diong TW; Haflah NHM; Kassim AYM; Habshi SMIA; Shukur MH
    J Hand Surg Asian Pac Vol; 2018 Mar; 23(1):26-32. PubMed ID: 29409409
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnosis of dorsal screw penetration after volar plating of a distal radial fracture.
    Langerhuizen DWG; Bergsma M; Selles CA; Jaarsma RL; Goslings JC; Schep NWL; Doornberg JN
    Bone Joint J; 2020 Jul; 102-B(7):874-880. PubMed ID: 32600133
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Volar plating in distal radius fractures: A prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration.
    Bergsma M; Doornberg JN; Duit R; Saarig A; Worsley D; Jaarsma R;
    Injury; 2018 Oct; 49(10):1810-1815. PubMed ID: 30017179
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Screw length in volar locking plate fixation for distal radial fractures.
    Yuen G; Yee DK; Fang C; Lau TW; Leung F
    J Orthop Surg (Hong Kong); 2015 Aug; 23(2):164-7. PubMed ID: 26321542
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study.
    Maschke SD; Evans PJ; Schub D; Drake R; Lawton JN
    Hand (N Y); 2007 Sep; 2(3):144-50. PubMed ID: 18780076
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study.
    Synek A; Borgmann L; Traxler H; Huf W; Euler E; Chevalier Y; Baumbach SF
    BMC Musculoskelet Disord; 2016 Mar; 17():120. PubMed ID: 26966085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius.
    Ozer K; Wolf JM; Watkins B; Hak DJ
    J Hand Surg Am; 2012 May; 37(5):963-7. PubMed ID: 22480500
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The dorsal horizon view: detecting screw protrusion at the distal radius.
    Joseph SJ; Harvey JN
    J Hand Surg Am; 2011 Oct; 36(10):1691-3. PubMed ID: 21864994
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predicting a safe screw length for volar plate fixation of distal radius fractures: lunate depth as a marker for distal radius depth.
    Ljungquist KL; Agnew SP; Huang JI
    J Hand Surg Am; 2015 May; 40(5):940-4. PubMed ID: 25747737
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dorsal Screw Penetration With the Use of Volar Plating of Distal Radius Fractures: How Can You Best Detect?
    Hill BW; Shakir I; Cannada LK
    J Orthop Trauma; 2015 Oct; 29(10):e408-13. PubMed ID: 26402306
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view.
    Haug LC; Glodny B; Deml C; Lutz M; Attal R
    Bone Joint J; 2013 Aug; 95-B(8):1101-5. PubMed ID: 23908427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius.
    Tweet ML; Calfee RP; Stern PJ
    J Hand Surg Am; 2010 Apr; 35(4):619-27. PubMed ID: 20202762
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Avoiding screw overlength using dorsal horizon view in palmar plate osteosynthesis of distal radius fractures: a prospective randomized trial.
    Lill M; Schauer T; Schultes P; Wierer G; Deml C; Windhofer C
    Arch Orthop Trauma Surg; 2024 Jan; 144(1):197-204. PubMed ID: 37726417
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures.
    Dardas AZ; Goldfarb CA; Boyer MI; Osei DA; Dy CJ; Calfee RP
    J Hand Surg Am; 2018 May; 43(5):448-454. PubMed ID: 29395586
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation.
    Oc Y; Kilinc BE; Gulcu A; Varol A; Ertugrul R; Kara A
    J Orthop Surg Res; 2018 Apr; 13(1):70. PubMed ID: 29615100
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Variable-angle locking screw volar plating of distal radius fractures.
    Park JH; Hagopian J; Ilyas AM
    Hand Clin; 2010 Aug; 26(3):373-80, vi. PubMed ID: 20670802
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensitivity and Specificity of Skyline and Carpal Shoot-Through Fluoroscopic Views of Volar Plate Fixation of the Distal Radius: A Cadaveric Investigation of Dorsal Cortex Screw Penetration.
    Stoops TK; Santoni BG; Clark NM; Bauer AA; Shoji C; Schwartz-Fernandes F
    Hand (N Y); 2017 Nov; 12(6):551-556. PubMed ID: 29091485
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Screw Length Optimization of a Volar Locking Plate Using Three Dimensional Preoperative Planning in Distal Radius Fractures.
    Totoki Y; Yoshii Y; Kusakabe T; Akita K; Ishii T
    J Hand Surg Asian Pac Vol; 2018 Dec; 23(4):520-527. PubMed ID: 30428809
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.