These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
157 related articles for article (PubMed ID: 28515757)
1. Emergency HeartWare Ventricular Assist Device (HVAD) exchange due to pump thrombosis using minimally invasive technique. Antończyk R; Trejnowska E; Pacholewicz J; Wolny T; Nadziakiewicz P; Antończyk K; Copik I; Piontek M; Jasińska M; Filipiak K; Głowacki M; Gawlikowski M; Borowicz M; Kustosz R; Waszak J; Przybyłowski P; Zembala M; Zakliczyński M; Zembala MO Kardiochir Torakochirurgia Pol; 2017 Mar; 14(1):76-78. PubMed ID: 28515757 [TBL] [Abstract][Full Text] [Related]
2. Treatment of device thrombus in the HeartWare HVAD: Success and outcomes depend significantly on the initial treatment strategy. Stulak JM; Dunlay SM; Sharma S; Haglund NA; Davis MB; Cowger J; Shah P; Masood F; Aaronson KD; Pagani FD; Maltais S J Heart Lung Transplant; 2015 Dec; 34(12):1535-41. PubMed ID: 26681123 [TBL] [Abstract][Full Text] [Related]
3. Conservative approaches for HeartWare ventricular assist device pump thrombosis may improve the outcome compared with immediate surgical approaches. Saeed D; Maxhera B; Albert A; Westenfeld R; Hoffmann T; Lichtenberg A Interact Cardiovasc Thorac Surg; 2016 Jul; 23(1):90-5. PubMed ID: 26993475 [TBL] [Abstract][Full Text] [Related]
4. First series of left ventricular assist device exchanges to HeartMate 3. Hanke JS; Rojas SV; Dogan G; Feldmann C; Beckmann E; Deniz E; Wiegmann B; Michaelis JE; Napp LC; Berliner D; Shrestha M; Bauersachs J; Haverich A; Schmitto JD Eur J Cardiothorac Surg; 2017 May; 51(5):887-892. PubMed ID: 28329060 [TBL] [Abstract][Full Text] [Related]
5. Minimally invasive thoracic left ventricular assist device implantation; case series demonstrating an integrated multidisciplinary strategy. Wagner CE; Bick JS; Kennedy J; Haglund N; Danter M; Davis ME; Shaw A; Maltais S J Cardiothorac Vasc Anesth; 2015 Apr; 29(2):271-4. PubMed ID: 25649695 [TBL] [Abstract][Full Text] [Related]
6. Off-pump left ventricular assist device exchange via re-do left mini-thoracotomy with original outflow graft preservation. Iwanski J; Tran PL; Jerman C; Smith R; Kazui T; Khalpey Z Perfusion; 2017 Apr; 32(3):179-182. PubMed ID: 27794072 [TBL] [Abstract][Full Text] [Related]
7. Device exchange from Heartmate II to HeartWare HVAD. Beaupre RA; Alnajar A; Sugiura T; Chou B; Lamba HK; Kurihara C; Kawabori M; Critsinelis AC; Santiago A; Morgan JA J Card Surg; 2019 Nov; 34(11):1204-1207. PubMed ID: 31478230 [TBL] [Abstract][Full Text] [Related]
8. An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial. Najjar SS; Slaughter MS; Pagani FD; Starling RC; McGee EC; Eckman P; Tatooles AJ; Moazami N; Kormos RL; Hathaway DR; Najarian KB; Bhat G; Aaronson KD; Boyce SW; J Heart Lung Transplant; 2014 Jan; 33(1):23-34. PubMed ID: 24418731 [TBL] [Abstract][Full Text] [Related]
9. Left ventricular assist device exchange for the treatment of HeartMate II pump thrombosis. Hanke JS; Dogan G; Wert L; Ricklefs M; Heimeshoff J; Chatterjee A; Feldmann C; Haverich A; Schmitto JD J Thorac Dis; 2018 Jun; 10(Suppl 15):S1728-S1736. PubMed ID: 30034845 [TBL] [Abstract][Full Text] [Related]
10. Thrombosis and cable damage in the HeartWare pump: clinical decisions and surgical technique. Potapov EV; Stepanenko A; Kaufmann F; Henning E; Vierecke J; Lehmkuhl E; Hetzer R; Krabatsch T ASAIO J; 2013; 59(1):37-40. PubMed ID: 23263342 [TBL] [Abstract][Full Text] [Related]
11. A minimally invasive off-pump implantation technique for continuous-flow left ventricular assist devices: early experience. Strueber M; Meyer AL; Feussner M; Ender J; Correia JC; Mohr FW J Heart Lung Transplant; 2014 Aug; 33(8):851-6. PubMed ID: 25063531 [TBL] [Abstract][Full Text] [Related]
12. Identification of characteristics, risk factors, and predictors of recurrent LVAD thrombosis: conditions in HeartWare devices. Gyoten T; Morshuis M; Rojas SV; Deutsch MA; Schramm R; Gummert JF; Fox H J Artif Organs; 2021 Jun; 24(2):173-181. PubMed ID: 33337536 [TBL] [Abstract][Full Text] [Related]
13. First results of HeartWare left ventricular assist device implantation with tunnelling of the outflow graft through the transverse sinus. Hanke JS; Rojas SV; Cvitkovic T; Wiegmann B; Horke A; Warnecke G; Haverich A; Schmitto JD Interact Cardiovasc Thorac Surg; 2017 Oct; 25(4):503-508. PubMed ID: 28962493 [TBL] [Abstract][Full Text] [Related]
14. Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices? Sabashnikov A; Popov AF; Bowles CT; Mohite PN; Weymann A; Hards R; Hedger M; Wittwer T; Wippermann J; Wahlers T; Schoendube FA; Simon AR J Thorac Cardiovasc Surg; 2014 Sep; 148(3):1115-21; discussion 1021-2. PubMed ID: 25129605 [TBL] [Abstract][Full Text] [Related]
15. Complex HeartWare left ventricular assist device infection treated with pump exchange: clinical alert for the driveline location. Domae K; Toda K; Yoshioka D; Miyagawa S; Yoshikawa Y; Hata H; Kainuma S; Kawamura T; Kawamura A; Sawa Y J Artif Organs; 2021 Sep; 24(3):377-381. PubMed ID: 33439371 [TBL] [Abstract][Full Text] [Related]