121 related articles for article (PubMed ID: 28516539)
21. Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans.
Ceylan C; Yondem Inal S; Senol E; Yilmaz B; Sahin S
Cureus; 2021 Jan; 13(1):e12684. PubMed ID: 33598374
[TBL] [Abstract][Full Text] [Related]
22. Automating linear accelerator quality assurance.
Eckhause T; Al-Hallaq H; Ritter T; DeMarco J; Farrey K; Pawlicki T; Kim GY; Popple R; Sharma V; Perez M; Park S; Booth JT; Thorwarth R; Moran JM
Med Phys; 2015 Oct; 42(10):6074-83. PubMed ID: 26429282
[TBL] [Abstract][Full Text] [Related]
23. Using an EPID for patient-specific VMAT quality assurance.
Bakhtiari M; Kumaraswamy L; Bailey DW; de Boer S; Malhotra HK; Podgorsak MB
Med Phys; 2011 Mar; 38(3):1366-73. PubMed ID: 21520847
[TBL] [Abstract][Full Text] [Related]
24. [RapidArc Delivery Performance Using EDR2 Film and EPID Measurement].
Ge R; Xu S; Xu W; Xie C; Cong X; Yang T
Zhongguo Yi Liao Qi Xie Za Zhi; 2016 May; 40(3):221-4. PubMed ID: 29775266
[TBL] [Abstract][Full Text] [Related]
25. Automatic detection of MLC relative position errors for VMAT using the EPID-based picket fence test.
Christophides D; Davies A; Fleckney M
Phys Med Biol; 2016 Dec; 61(23):8340-8359. PubMed ID: 27811392
[TBL] [Abstract][Full Text] [Related]
26. Comparisons of volumetric modulated arc therapy (VMAT) quality assurance (QA) systems: sensitivity analysis to machine errors.
Liang B; Liu B; Zhou F; Yin FF; Wu Q
Radiat Oncol; 2016 Nov; 11(1):146. PubMed ID: 27821135
[TBL] [Abstract][Full Text] [Related]
27. SU-E-T-196: Commissioning for Volumetric Modulated Radiation Therapy on Varian Clinac 21EX.
Yada R; Hayashi N; Matsunaga T; Nozue M; Sai H; Yamada K; Yamanaka R; Kato Y; Muraki Y
Med Phys; 2012 Jun; 39(6Part12):3748. PubMed ID: 28517818
[TBL] [Abstract][Full Text] [Related]
28. SU-E-T-382: An Analysis of VMAT Monthly Quality Assurance.
Stenbeck J; Oves S; Gebreamlak W; Alkhatib H
Med Phys; 2012 Jun; 39(6Part16):3792. PubMed ID: 28517210
[TBL] [Abstract][Full Text] [Related]
29. Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries.
McCowan PM; McCurdy BM
Med Phys; 2016 Jan; 43(1):254. PubMed ID: 26745918
[TBL] [Abstract][Full Text] [Related]
30. Independent verification of gantry angle for pre-treatment VMAT QA using EPID.
Adamson J; Wu Q
Phys Med Biol; 2012 Oct; 57(20):6587-600. PubMed ID: 23010739
[TBL] [Abstract][Full Text] [Related]
31. SU-E-T-119: Evaluation of New VMAT and IMRT Planning QA Devices: Portal Dosimetry Vs Compass.
Kum O; Shin H; Han Y
Med Phys; 2012 Jun; 39(6Part11):3730. PubMed ID: 28517115
[TBL] [Abstract][Full Text] [Related]
32. A study on dosimetric properties of electronic portal imaging device and its use as a quality assurance tool in Volumetric Modulated Arc Therapy.
Sukumar P; Padmanaban S; Jeevanandam P; Syam Kumar SA; Nagarajan V
Rep Pract Oncol Radiother; 2011; 16(6):248-55. PubMed ID: 24376989
[TBL] [Abstract][Full Text] [Related]
33. An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments.
Rowshanfarzad P; McGarry CK; Barnes MP; Sabet M; Ebert MA
Radiat Oncol; 2014 Nov; 9():249. PubMed ID: 25424471
[TBL] [Abstract][Full Text] [Related]
34. SU-E-J-14: Evaluation of Mechanical Accuracy of Electronic Portal Imaging Devise on Its Use in Patient Specific IMRT QA.
Li J; Burman C; Chan M
Med Phys; 2012 Jun; 39(6Part6):3655. PubMed ID: 28517581
[TBL] [Abstract][Full Text] [Related]
35. Comparison of pretreatment VMAT quality assurance with the integral quality monitor (IQM) and electronic portal imaging device (EPID).
Ghafarian M; Price M; Morales-Paliza M
J Appl Clin Med Phys; 2021 Mar; 22(3):166-175. PubMed ID: 33596336
[TBL] [Abstract][Full Text] [Related]
36. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.
Mohammadi M; Bezak E
Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123
[TBL] [Abstract][Full Text] [Related]
37. An Investigation of Multileaf Collimator Performance Dependence on Gantry Angle Using Machine Log Files.
Hughes JL; Ebert MA; McGarry CK; Agnew CE; Sabet M; Rowshanfarzad P
J Med Phys; 2021; 46(4):300-307. PubMed ID: 35261500
[TBL] [Abstract][Full Text] [Related]
38. SU-E-T-193: Using Truebeam's Research Mode to Automate Mechanical Quality Assurance.
Grantham K; Rangaraj D; Santanam L
Med Phys; 2012 Jun; 39(6Part12):3747. PubMed ID: 28517798
[TBL] [Abstract][Full Text] [Related]
39. Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).
Anvari A; Poirier Y; Sawant A
Med Phys; 2018 Jul; 45(7):3246-3257. PubMed ID: 29704440
[TBL] [Abstract][Full Text] [Related]
40. Insensitivity of machine log files to MLC leaf backlash and effect of MLC backlash on clinical dynamic MLC motion: An experimental investigation.
Barnes M; Pomare D; Doebrich M; Standen TS; Wolf J; Greer P; Simpson J
J Appl Clin Med Phys; 2022 Sep; 23(9):e13660. PubMed ID: 35678793
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]