158 related articles for article (PubMed ID: 28516744)
1. Repetitive Nerve Stimulation in MuSK-Antibody-Positive Myasthenia Gravis.
Kim SW; Sunwoo MK; Kim SM; Shin HY; Sunwoo IN
J Clin Neurol; 2017 Jul; 13(3):287-292. PubMed ID: 28516744
[TBL] [Abstract][Full Text] [Related]
2. Repetitive nerve stimulation of facial muscles in MuSK antibody-positive myasthenia gravis.
Oh SJ; Hatanaka Y; Hemmi S; Young AM; Scheufele ML; Nations SP; Lu L; Claussen GC; Wolfe GI
Muscle Nerve; 2006 Apr; 33(4):500-4. PubMed ID: 16392120
[TBL] [Abstract][Full Text] [Related]
3. Initial Repetitive Nerve Stimulation Test Predicts Conversion of Ocular Myasthenia Gravis to Generalized Myasthenia Gravis.
Kim KH; Kim SW; Shin HY
J Clin Neurol; 2021 Apr; 17(2):265-272. PubMed ID: 33835748
[TBL] [Abstract][Full Text] [Related]
4. Repetitive nerve stimulation test in amyotrophic lateral sclerosis with predominant oropharyngeal manifestations.
Kim JY; Park KD; Kim SM; Sunwoo IN
J Clin Neurol; 2011 Mar; 7(1):31-3. PubMed ID: 21519524
[TBL] [Abstract][Full Text] [Related]
5. [Clinical characteristics and outcomes of myasthenia gravis patients with double positive antibodies against acetylcholine receptor and muscle-specific tyrosine kinase].
Lu YR; Yu L; Ma Q; Chen P; Qiu L; Ou CY; Lin ZZ; Liu WB
Zhonghua Yi Xue Za Zhi; 2022 Apr; 102(13):942-947. PubMed ID: 35385966
[No Abstract] [Full Text] [Related]
6. Clinical phenotype of muscle-specific tyrosine kinase-antibody-positive myasthenia gravis.
Wolfe GI; Oh SJ
Ann N Y Acad Sci; 2008; 1132():71-5. PubMed ID: 18567855
[TBL] [Abstract][Full Text] [Related]
7. A study of diagnostic yield, technical ease and patient discomfort of low rate repetitive nerve stimulation test in patients with myasthenia gravis.
Misra UK; Kalita J; Srivastava A
Electromyogr Clin Neurophysiol; 2006 Nov; 46(6):337-41. PubMed ID: 17147075
[TBL] [Abstract][Full Text] [Related]
8. Electrophysiological profile of the patients with MuSK positive myasthenia gravis.
Nikolic A; Basta I; Stojanovic VR; Stevic Z; Lavrnic D
Neurol Res; 2014 Nov; 36(11):945-9. PubMed ID: 24825477
[TBL] [Abstract][Full Text] [Related]
9. Repetitive nerve stimulation in myasthenia gravis--relative sensitivity of different muscles.
Costa J; Evangelista T; Conceição I; de Carvalho M
Clin Neurophysiol; 2004 Dec; 115(12):2776-82. PubMed ID: 15546785
[TBL] [Abstract][Full Text] [Related]
10. Occipitalis muscle: using for repetitive facial nerve stimulation in myasthenia gravis.
Yildirim A; Adatepe T; Gunduz A; Yagiz O; Uzun N
Acta Neurol Belg; 2020 Jun; 120(3):609-613. PubMed ID: 29428994
[TBL] [Abstract][Full Text] [Related]
11. Electrophysiological studies in patients with seropositive/seronegative myasthenia gravis.
Vahabi Z; Nazari F; Fatehi F; Bayegi V; Saffarian Z; Saffarian F; Nafissi S
Curr J Neurol; 2021 Jul; 20(3):120-124. PubMed ID: 38011446
[No Abstract] [Full Text] [Related]
12. MRI and clinical studies of facial and bulbar muscle involvement in MuSK antibody-associated myasthenia gravis.
Farrugia ME; Robson MD; Clover L; Anslow P; Newsom-Davis J; Kennett R; Hilton-Jones D; Matthews PM; Vincent A
Brain; 2006 Jun; 129(Pt 6):1481-92. PubMed ID: 16672291
[TBL] [Abstract][Full Text] [Related]
13. Afterdischarges in Myasthenia Gravis.
Yang L; Guo S; Chen X
Front Neurol; 2021; 12():599744. PubMed ID: 33927677
[No Abstract] [Full Text] [Related]
14. Comparison of Fixed and Live Cell-Based Assay for the Detection of AChR and MuSK Antibodies in Myasthenia Gravis.
Spagni G; Gastaldi M; Businaro P; Chemkhi Z; Carrozza C; Mascagna G; Falso S; Scaranzin S; Franciotta D; Evoli A; Damato V
Neurol Neuroimmunol Neuroinflamm; 2023 Jan; 10(1):. PubMed ID: 36270951
[TBL] [Abstract][Full Text] [Related]
15. Relative fatigability of muscles in response to repetitive nerve stimulation in myasthenia gravis.
Witoonpanich R; Barakul S; Dejthevaporn C
J Med Assoc Thai; 2006 Dec; 89(12):2047-9. PubMed ID: 17214055
[TBL] [Abstract][Full Text] [Related]
16. [Characteristics of low frequency repetitive nerve stimulation in patients with myasthenia gravis and its correlation with clinical features].
He XT; Wang LJ; Chen JL; Xie CG; Gan R; Yang R
Zhonghua Yi Xue Za Zhi; 2021 Aug; 101(31):2443-2447. PubMed ID: 34399557
[No Abstract] [Full Text] [Related]
17. MuSK-antibody positive myasthenia gravis: clinical and electrodiagnostic patterns.
Stickler DE; Massey JM; Sanders DB
Clin Neurophysiol; 2005 Sep; 116(9):2065-8. PubMed ID: 16043398
[TBL] [Abstract][Full Text] [Related]
18. Repetitive nerve stimulation and jitter measurement with disposable concentric needle electrode in newly diagnosed myasthenia gravis patients.
Sirin NG; Kocasoy Orhan E; Durmus H; Deymeer F; Baslo MB
Neurophysiol Clin; 2018 Oct; 48(5):261-267. PubMed ID: 29490884
[TBL] [Abstract][Full Text] [Related]
19. Decremental responses to repetitive nerve stimulation in x-linked bulbospinal muscular atrophy.
Kim JY; Park KD; Kim SM; Sunwoo IN
J Clin Neurol; 2013 Jan; 9(1):32-5. PubMed ID: 23346158
[TBL] [Abstract][Full Text] [Related]
20. A comparative study of single fiber electromyography and repetitive nerve stimulation in consecutive patients with myasthenia gravis.
Srivastava A; Kalita J; Misra UK
Electromyogr Clin Neurophysiol; 2007; 47(2):93-6. PubMed ID: 17479725
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]