BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

65 related articles for article (PubMed ID: 28517159)

  • 1. SU-E-T-138: Quantification of Dwell Position Inaccuracy in Varian GammaMed HDR Titanium Ring Applicators.
    Iftimia I; Cirino E; Mower H; McKee A
    Med Phys; 2012 Jun; 39(6Part11):3735. PubMed ID: 28517159
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dwell position inaccuracy in the Varian GammaMed HDR ring applicator.
    Stern RL; Liu T
    J Appl Clin Med Phys; 2010 Sep; 11(4):3158. PubMed ID: 21081871
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas.
    Awunor O; Berger D; Kirisits C
    Med Phys; 2015 Aug; 42(8):4472-83. PubMed ID: 26233177
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new approach to measure dwell position inaccuracy in HDR ring applicators - quantification and corrective QA.
    Jangda AQ; Hussein S; Rehman Z
    J Appl Clin Med Phys; 2010 Sep; 12(1):3355. PubMed ID: 21330984
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.
    McMahon R; Zhuang T; Steffey BA; Song H; Craciunescu OI
    J Appl Clin Med Phys; 2011 Nov; 12(4):3447. PubMed ID: 22089000
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Direct reconstruction and associated uncertainties of 192Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients.
    Awunor OA; Dixon B; Walker C
    Phys Med Biol; 2013 May; 58(10):3207-25. PubMed ID: 23603854
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.
    Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
    Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SU-E-T-318: Source Position Localization for ICBT Tandem & Ovoid Applicators Utilizing Oncentra Brachy Applicator Modeling.
    Kemp J; Price M
    Med Phys; 2012 Jun; 39(6Part14):3777. PubMed ID: 28517249
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric comparison of ring and ovoid applicators.
    Tuncell N; Toy A; Demiral AN; Cetingoz R; Garipagaoglu M
    J BUON; 2009; 14(3):451-5. PubMed ID: 19810138
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance.
    Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfelda AB
    Med Phys; 2015 Feb; 42(2):663-73. PubMed ID: 25771556
    [TBL] [Abstract][Full Text] [Related]  

  • 12. SU-E-T-307: Quantitative Assessment of the Source Attenuation for the New CT-Compatible Titanium Fletcher-Suit-Delclos (FSD) Gynecologic Applicator.
    Soni N; Gautam B; Shvydka D; Parsai E
    Med Phys; 2012 Jun; 39(6Part14):3774. PubMed ID: 28517254
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of transit dose profile for a (192)Ir HDR source.
    Fonseca GP; Rubo RA; Minamisawa RA; dos Santos GR; Antunes PC; Yoriyaz H
    Med Phys; 2013 May; 40(5):051717. PubMed ID: 23635265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. SU-E-T-229: Monte Carlo Dosimetric Study of SAVI HDR Applicator for Partial Breast Irradiation.
    Zhang Z; Dou K
    Med Phys; 2012 Jun; 39(6Part13):3756. PubMed ID: 28517358
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A quality assurance tool for high-dose-rate brachytherapy.
    Rickey DW; Sasaki D; Bews J
    Med Phys; 2010 Jun; 37(6):2525-32. PubMed ID: 20632564
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SU-E-T-315: Planning and Verification of CT-Based HDR Intraluminal Brachytherapy Treatment for Malignant Obstructive Jaundice.
    Svoboda A; Lo Y; Sheu R; Dumane V; Rosenzweig K
    Med Phys; 2012 Jun; 39(6Part14):3776. PubMed ID: 28517247
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SU-E-T-320: A New Verification Phantom for GYN Brachytherapy Applicators Using GafChromic - Films.
    Gholami S; Meigooni AS; Mahdavi SM; Mirzaei H
    Med Phys; 2012 Jun; 39(6Part14):3777. PubMed ID: 28517282
    [TBL] [Abstract][Full Text] [Related]  

  • 18. BrachyView, a novel inbody imaging system for HDR prostate brachytherapy: design and Monte Carlo feasibility study.
    Safavi-Naeini M; Han Z; Cutajar D; Guatelli S; Petasecca M; Lerch ML; Franklin DR; Jakubek J; Pospisil S; Bucci J; Zaider M; Rosenfeld AB
    Med Phys; 2013 Jul; 40(7):071715. PubMed ID: 23822419
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of transit time of a remote after-loading high dose rate brachytherapy source.
    Sahoo N
    Med Phys; 2001 Aug; 28(8):1786-90. PubMed ID: 11548950
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al(2)O(3):C dosimetry and a novel statistical error decision criterion.
    Kertzscher G; Andersen CE; Siebert FA; Nielsen SK; Lindegaard JC; Tanderup K
    Radiother Oncol; 2011 Sep; 100(3):456-62. PubMed ID: 21963285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.