82 related articles for article (PubMed ID: 28517201)
1. SU-E-T-420: Development of a Comprehensive Linac-Based Quality Assurance Procedure for Retrofitted Micro-MLC SRS System. Hancock G; Pearson D Med Phys; 2012 Jun; 39(6Part16):3801. PubMed ID: 28517201 [TBL] [Abstract][Full Text] [Related]
2. Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery. Shen J; Robertson DG; Bues M; Shipulin K; Liu W; Stoker J; Ashman JB; Lara P; Keole SR; Wong W; Vora SA Med Phys; 2023 Jun; 50(6):3359-3367. PubMed ID: 36959772 [TBL] [Abstract][Full Text] [Related]
3. SU-E-J-49: Reliability Study of ExacTrac- System Image Isocenter Using an On-Demand QA Procedure. Wang X; Zhao Z; Du W; Li X; Yang J Med Phys; 2012 Jun; 39(6Part6):3663. PubMed ID: 28517561 [TBL] [Abstract][Full Text] [Related]
4. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery. Rowshanfarzad P; Sabet M; O'Connor DJ; Greer PB Med Phys; 2011 Jul; 38(7):3963-70. PubMed ID: 21858993 [TBL] [Abstract][Full Text] [Related]
5. SU-E-T-413: Dose Verification for Linac-Based SRS Commissioning and Patient Specific QA. Wu J; Wu H Med Phys; 2012 Jun; 39(6Part16):3799. PubMed ID: 28517179 [TBL] [Abstract][Full Text] [Related]
6. An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position. Rosca F; Lorenz F; Hacker FL; Chin LM; Ramakrishna N; Zygmanski P Med Phys; 2006 Jun; 33(6):1780-7. PubMed ID: 16872085 [TBL] [Abstract][Full Text] [Related]
7. Automating linear accelerator quality assurance. Eckhause T; Al-Hallaq H; Ritter T; DeMarco J; Farrey K; Pawlicki T; Kim GY; Popple R; Sharma V; Perez M; Park S; Booth JT; Thorwarth R; Moran JM Med Phys; 2015 Oct; 42(10):6074-83. PubMed ID: 26429282 [TBL] [Abstract][Full Text] [Related]
8. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator. Riis HL; Zimmermann SJ; Hjelm-Hansen M Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302 [TBL] [Abstract][Full Text] [Related]
9. Commissioning and clinical implementation of a sliding gantry CT scanner installed in an existing treatment room and early clinical experience for precise tumor localization. Cheng CW; Wong J; Grimm L; Chow M; Uematsu M; Fung A Am J Clin Oncol; 2003 Jun; 26(3):e28-36. PubMed ID: 12796613 [TBL] [Abstract][Full Text] [Related]
10. SU-E-T-88: Evaluating Gantry Sag on Linear Accelerators and Introducing an MLC-Based Compensation Strategy. Du W; Gao S; Wang X; Kudchadker R Med Phys; 2012 Jun; 39(6Part11):3722-3723. PubMed ID: 28517157 [TBL] [Abstract][Full Text] [Related]
11. SU-E-T-193: Using Truebeam's Research Mode to Automate Mechanical Quality Assurance. Grantham K; Rangaraj D; Santanam L Med Phys; 2012 Jun; 39(6Part12):3747. PubMed ID: 28517798 [TBL] [Abstract][Full Text] [Related]
12. SU-E-T-24: Development and Implementation of an Automated Algorithm to Determine Radiation Isocenter, Radiation vs. Light Field Coincidence, and Analyze Strip Tests. Hyer D; Mart C Med Phys; 2012 Jun; 39(6Part9):3707. PubMed ID: 28519067 [TBL] [Abstract][Full Text] [Related]
13. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests. Du W; Johnson JL; Jiang W; Kudchadker RJ J Appl Clin Med Phys; 2016 Jan; 17(1):167-178. PubMed ID: 26894350 [TBL] [Abstract][Full Text] [Related]
14. Filmless methods for quality assurance of Tomotherapy using ArcCHECK. Yang B; Wong WK; Geng H; Lam WW; Ho YW; Kwok WM; Cheung KY; Yu SK Med Phys; 2017 Jan; 44(1):7-16. PubMed ID: 28044341 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of the RUBY modular QA phantom for planar and non-coplanar VMAT and stereotactic radiations. Poppinga D; Kretschmer J; Brodbek L; Meyners J; Poppe B; Looe HK J Appl Clin Med Phys; 2020 Oct; 21(10):69-79. PubMed ID: 32797670 [TBL] [Abstract][Full Text] [Related]
16. [Gantry QA Using Three-dimensional Diode Array Detector on O-ring Linear Accelerator]. Sakamoto T; Matsumoto K; Otsuka M; Nanbu H; Okumura M Nihon Hoshasen Gijutsu Gakkai Zasshi; 2022; 78(3):263-269. PubMed ID: 35314535 [TBL] [Abstract][Full Text] [Related]
17. A novel method for routine quality assurance of volumetric-modulated arc therapy. Wang Q; Dai J; Zhang K Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902 [TBL] [Abstract][Full Text] [Related]
18. Technical Note: Unified imaging and robotic couch quality assurance. Cook MC; Roper J; Elder ES; Schreibmann E Med Phys; 2016 Sep; 43(9):5080. PubMed ID: 27587038 [TBL] [Abstract][Full Text] [Related]
19. SU-E-T-133: Isocenter Measurements with the Winston-Lutz Test: Impact on Treatment Planning. Templeton A; Chu J; Turian J Med Phys; 2012 Jun; 39(6Part11):3733-3734. PubMed ID: 28517166 [TBL] [Abstract][Full Text] [Related]
20. Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery. Zhu J Med Phys; 2011 Jan; 38(1):390-6. PubMed ID: 21361207 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]