83 related articles for article (PubMed ID: 28517287)
1. SU-E-T-309: Dosimetric Study and Clinical Implementation of an HDR Applicator of SAVI for Partial Breast Irradiation.
Dou K; Lerma F; Jacobs M; Ottinger M; Seidel M; Herchko M; Reynolds S
Med Phys; 2012 Jun; 39(6Part14):3774. PubMed ID: 28517287
[TBL] [Abstract][Full Text] [Related]
2. SU-E-T-229: Monte Carlo Dosimetric Study of SAVI HDR Applicator for Partial Breast Irradiation.
Zhang Z; Dou K
Med Phys; 2012 Jun; 39(6Part13):3756. PubMed ID: 28517358
[TBL] [Abstract][Full Text] [Related]
3. Dosimetry evaluation of SAVI-based HDR brachytherapy for partial breast irradiation.
Manoharan SR; Rodriguez RR; Bobba VS; Chandrashekar M
J Med Phys; 2010 Jul; 35(3):131-6. PubMed ID: 20927219
[TBL] [Abstract][Full Text] [Related]
4. SU-E-T-322: A Dosimetric Comparison of PBI Brachytherapy Techniques: SAVI, Contura, and Tube and Button Applicators.
Park S; Kamrava M; Demanes J
Med Phys; 2012 Jun; 39(6Part14):3778. PubMed ID: 28517257
[TBL] [Abstract][Full Text] [Related]
5. Clinical implementation of a new HDR brachytherapy device for partial breast irradiation.
Scanderbeg DJ; Yashar C; Rice R; Pawlicki T
Radiother Oncol; 2009 Jan; 90(1):36-42. PubMed ID: 18952310
[TBL] [Abstract][Full Text] [Related]
6. SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.
Jacob D; Strasser J
Med Phys; 2012 Jun; 39(6Part13):3757. PubMed ID: 28517320
[TBL] [Abstract][Full Text] [Related]
7. Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm.
Mazur TR; Hao Y; Garcia-Ramirez J; Altman MB; Li HH; Thomas MA; Zoberi I; Zoberi JE
Int J Radiat Oncol Biol Phys; 2021 Jul; 110(4):1200-1209. PubMed ID: 33662458
[TBL] [Abstract][Full Text] [Related]
8. Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes.
Rana Z; Nasr NM; Ji H; Lorio V; Akbari S; Sebastian M; Martin M; Hong RL
Radiat Oncol; 2015 Jul; 10():160. PubMed ID: 26227388
[TBL] [Abstract][Full Text] [Related]
9. SU-E-T-432: Comparison of HDR Treatment Plans for Interstitial Brachytherapy with Intracavitary Savi Brachytherapy for Post Lumpectomy Breast Cancer.
Nair M; Anderson P; Neumann T; Vance W; White M; Davis J
Med Phys; 2012 Jun; 39(6Part16):3804. PubMed ID: 28517223
[TBL] [Abstract][Full Text] [Related]
10. Accelerated partial breast irradiation dosimetric criteria for the strut-adjusted volume implant.
Mooney KE; Altman MB; Edward S; Garcia-Ramirez J; Thomas MA; Zoberi I; DeWees T; Mullen D; Zoberi JE
Brachytherapy; 2016; 15(5):616-24. PubMed ID: 27349857
[TBL] [Abstract][Full Text] [Related]
11. Comparison of planning techniques when air/fluid is present using the strut-adjusted volume implant (SAVI) for HDR-based accelerated partial breast irradiation.
Harmon JF; Rice BK
J Appl Clin Med Phys; 2013 Nov; 14(6):4442. PubMed ID: 24257287
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric effects of an air cavity for the SAVI partial breast irradiation applicator.
Richardson SL; Pino R
Med Phys; 2010 Aug; 37(8):3919-26. PubMed ID: 20879554
[TBL] [Abstract][Full Text] [Related]
13. Initial clinical experience with the Strut-Adjusted Volume Implant brachytherapy applicator for accelerated partial breast irradiation.
Yashar CM; Blair S; Wallace A; Scanderbeg D
Brachytherapy; 2009; 8(4):367-72. PubMed ID: 19744892
[TBL] [Abstract][Full Text] [Related]
14. Accelerated partial breast irradiation: a dosimetric comparison of three different techniques.
Weed DW; Edmundson GK; Vicini FA; Chen PY; Martinez AA
Brachytherapy; 2005; 4(2):121-9. PubMed ID: 15893265
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of three APBI techniques under NSABP B-39 guidelines.
Scanderbeg D; Yashar C; White G; Rice R; Pawlicki T
J Appl Clin Med Phys; 2009 Dec; 11(1):3021. PubMed ID: 20160680
[TBL] [Abstract][Full Text] [Related]
16. On the feasibility of treating to a 1.5 cm PTV with a commercial single-entry hybrid applicator in APBI breast brachytherapy.
Gifford KA; Nelson CL; Kirsner SM; Kisling KD; Ballo MT; Bloom ES
J Contemp Brachytherapy; 2012 Mar; 4(1):29-33. PubMed ID: 23346137
[TBL] [Abstract][Full Text] [Related]
17. Analysis of applicator displacement in accelerated partial breast irradiation using a strut-based design brachytherapy applicator.
Kubo T; Kurokawa C; Inoue T; Fujii T; Miyaura K; Shinjo H; Kagami Y; Shikama N
Brachytherapy; 2023; 22(5):655-664. PubMed ID: 37455152
[TBL] [Abstract][Full Text] [Related]
18. Inter-fractional variations in the dosimetric parameters of accelerated partial breast irradiation using a strut-adjusted volume implant.
Iijima K; Okamoto H; Takahashi K; Aikawa A; Wakita A; Nakamura S; Nishioka S; Harada K; Notake R; Sugawara A; Yoshimura R; Kunieda E; Itami J
J Radiat Res; 2020 Jan; 61(1):123-133. PubMed ID: 31665490
[TBL] [Abstract][Full Text] [Related]
19. 3D CT-based high-dose-rate breast brachytherapy implants: treatment planning and quality assurance.
Das RK; Patel R; Shah H; Odau H; Kuske RR
Int J Radiat Oncol Biol Phys; 2004 Jul; 59(4):1224-8. PubMed ID: 15234059
[TBL] [Abstract][Full Text] [Related]
20. Study on the dose modification factor of strut adjusted volume implant (SAVI) with a
Vahabi SM; Bahreinipour M; Shamsaie Zafarghandi M
Australas Phys Eng Sci Med; 2018 Jun; 41(2):445-450. PubMed ID: 29756165
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]