85 related articles for article (PubMed ID: 28517358)
1. SU-E-T-229: Monte Carlo Dosimetric Study of SAVI HDR Applicator for Partial Breast Irradiation.
Zhang Z; Dou K
Med Phys; 2012 Jun; 39(6Part13):3756. PubMed ID: 28517358
[TBL] [Abstract][Full Text] [Related]
2. SU-E-T-309: Dosimetric Study and Clinical Implementation of an HDR Applicator of SAVI for Partial Breast Irradiation.
Dou K; Lerma F; Jacobs M; Ottinger M; Seidel M; Herchko M; Reynolds S
Med Phys; 2012 Jun; 39(6Part14):3774. PubMed ID: 28517287
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric effects of an air cavity for the SAVI partial breast irradiation applicator.
Richardson SL; Pino R
Med Phys; 2010 Aug; 37(8):3919-26. PubMed ID: 20879554
[TBL] [Abstract][Full Text] [Related]
4. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions.
Candela-Juan C; Niatsetski Y; van der Laarse R; Granero D; Ballester F; Perez-Calatayud J; Vijande J
Med Phys; 2016 Apr; 43(4):1639. PubMed ID: 27036563
[TBL] [Abstract][Full Text] [Related]
5. SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.
Jacob D; Strasser J
Med Phys; 2012 Jun; 39(6Part13):3757. PubMed ID: 28517320
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing.
Yang Y; Rivard MJ
Med Phys; 2010 Nov; 37(11):5665-71. PubMed ID: 21158278
[TBL] [Abstract][Full Text] [Related]
7. SU-E-T-432: Comparison of HDR Treatment Plans for Interstitial Brachytherapy with Intracavitary Savi Brachytherapy for Post Lumpectomy Breast Cancer.
Nair M; Anderson P; Neumann T; Vance W; White M; Davis J
Med Phys; 2012 Jun; 39(6Part16):3804. PubMed ID: 28517223
[TBL] [Abstract][Full Text] [Related]
8. Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator.
Petrokokkinos L; Zourari K; Pantelis E; Moutsatsos A; Karaiskos P; Sakelliou L; Seimenis I; Georgiou E; Papagiannis P
Med Phys; 2011 Apr; 38(4):1981-92. PubMed ID: 21626931
[TBL] [Abstract][Full Text] [Related]
9. Study on the dose modification factor of strut adjusted volume implant (SAVI) with a
Vahabi SM; Bahreinipour M; Shamsaie Zafarghandi M
Australas Phys Eng Sci Med; 2018 Jun; 41(2):445-450. PubMed ID: 29756165
[TBL] [Abstract][Full Text] [Related]
10. Dosimetry of MammoSite® applicator: comparison between Monte Carlo simulation, measurements, and treatment planning calculation.
Oshaghi M; Sadeghi M; Mahdavi SR; Shirazi A
J Cancer Res Ther; 2013; 9(2):224-9. PubMed ID: 23771363
[TBL] [Abstract][Full Text] [Related]
11. Treatment volume and dose optimization of MammoSite breast brachytherapy applicator.
Dickler A; Kirk M; Choo J; Hsi WC; Chu J; Dowlatshahi K; Francescatti D; Nguyen C
Int J Radiat Oncol Biol Phys; 2004 Jun; 59(2):469-74. PubMed ID: 15145164
[TBL] [Abstract][Full Text] [Related]
12. SU-D-213AB-04: Evaluation of the Dose Calculation in a Commercial Planning System for a Breast Cancer Brachytherapy Technology Using Monte Carlo Simulation.
Graf M; Cervino L; Scanderbeg D; Yashar C; Jiang S
Med Phys; 2012 Jun; 39(6Part3):3612. PubMed ID: 28517425
[TBL] [Abstract][Full Text] [Related]
13. Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes.
Rana Z; Nasr NM; Ji H; Lorio V; Akbari S; Sebastian M; Martin M; Hong RL
Radiat Oncol; 2015 Jul; 10():160. PubMed ID: 26227388
[TBL] [Abstract][Full Text] [Related]
14. SU-E-T-322: A Dosimetric Comparison of PBI Brachytherapy Techniques: SAVI, Contura, and Tube and Button Applicators.
Park S; Kamrava M; Demanes J
Med Phys; 2012 Jun; 39(6Part14):3778. PubMed ID: 28517257
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric characterization of a novel intracavitary mold applicator for 192Ir high dose rate endorectal brachytherapy treatment.
Poon E; Reniers B; Devic S; Vuong T; Verhaegen F
Med Phys; 2006 Dec; 33(12):4515-26. PubMed ID: 17278803
[TBL] [Abstract][Full Text] [Related]
16. Dosimetry evaluation of SAVI-based HDR brachytherapy for partial breast irradiation.
Manoharan SR; Rodriguez RR; Bobba VS; Chandrashekar M
J Med Phys; 2010 Jul; 35(3):131-6. PubMed ID: 20927219
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric analysis of a shielded applicator for nasopharyngeal carcinoma intracavitary brachytherapy: Monte Carlo calculation.
Chen LX; Liu XW; You RA; Qian JY; Qi ZY; Deng XW; Tsao SY
Med Phys; 2006 Mar; 33(3):761-9. PubMed ID: 16878578
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo model for a prototype CT-compatible, anatomically adaptive, shielded intracavitary brachytherapy applicator for the treatment of cervical cancer.
Price MJ; Gifford KA; Horton JL; Eifel PJ; Gillin MT; Lawyer AA; Mourtada F
Med Phys; 2009 Sep; 36(9):4147-55. PubMed ID: 19810488
[TBL] [Abstract][Full Text] [Related]
19. SU-E-T-518: Dose Perturbation at Air-Tissue Interface in Proton Beam Therapy.
Das I; Moskvin V; Coutinho L; Cheng C
Med Phys; 2012 Jun; 39(6Part18):3824. PubMed ID: 28518489
[TBL] [Abstract][Full Text] [Related]
20. Experimental and Monte Carlo dosimetry of the Henschke applicator for high dose-rate 192Ir remote afterloading.
Watanabe Y; Roy J; Harrington PJ; Anderson LL
Med Phys; 1998 May; 25(5):736-45. PubMed ID: 9608485
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]